1. Product Overview
The SONGGER PP Side Mount Float Level Switch is a compact and reliable sensor designed for point-level detection of liquids in tanks and containers. It operates using a magnetic reed switch mechanism integrated within the float assembly. As the liquid level changes, the float moves, triggering the internal reed contact to open or close the circuit, providing an electrical signal for control or indication.
The housing is constructed from polypropylene (PP), offering excellent chemical resistance to acids and alkalis, making it suitable for a wide range of applications including water treatment, industrial process control, and general liquid level monitoring.
2. Specifications
This float level switch is available in two versions: Low Voltage and High Voltage, each with distinct electrical ratings.
| Specification | Low Voltage (Low) | High Voltage (High) |
|---|---|---|
| Max Power | 10W | 50W |
| Max Voltage | 110VDC | 220VAC |
| Max Current | 0.2A | 0.5A |
| Breakdown Voltage | 220VDC | 300VAC |
| Temperature Range | -10°C to +60°C | -20°C to +90°C |
| Material | Polypropylene (PP) | |
| Mounting Type | Side mount, M12 x 1.25 threaded connection | |
| Wire Length | 0.4m standard (customizable to 1m, 2m, 5m, 10m or as specified) | |
| Operating Principle | Magnetic reed switch | |
| Suitable Media | Water and compatible liquids with PP material | |
3. Setup and Installation
3.1. Preparation
- Verify that the selected model matches the system voltage and power requirements.
- Ensure the liquid in the tank is chemically compatible with polypropylene material to prevent degradation.
- Check that the mounting port on your tank matches the M12 x 1.25 thread specification of the float switch.
- Ensure an external power source is available for operation.
3.2. Installation
- Install the float switch horizontally on the tank wall using the M12 x 1.25 threaded connection.
- Ensure proper sealing using a suitable gasket or sealing tape to prevent any leakage.
- Orient the float according to the required normally open or normally closed configuration for your application.
3.3. Electrical Connection
WARNING! Risk of electric shock if used with high voltage circuits. Disconnect power supply before installation or maintenance.
- Connect the two lead wires of the float switch in series with your control circuit.
- Ensure that the load connected to the switch does not exceed the specified maximum voltage, current, and power rating to prevent overheating or fire hazard.
- Ensure proper grounding of associated equipment.
- For controlling high-power devices like water pumps or alarms, a relay is required to prevent misoperation and damage to the float switch.
4. Operation
4.1. Basic Operation
When the liquid level in the tank reaches the position of the float, the internal magnetic reed switch changes its state (either opening or closing the circuit). This change in state generates an output signal.
4.2. Output Signal Usage
The output signal can be used to:
- Control relays for activating pumps or other equipment.
- Trigger alarms to indicate specific liquid levels.
- Provide digital inputs to Programmable Logic Controllers (PLCs) for automated systems.
4.3. Commissioning
After installation and wiring, verify the switching function by gradually filling or draining the tank. Observe the response of the connected control system (e.g., pump activation, alarm sounding) to ensure correct operation.
5. Maintenance
5.1. General Maintenance
- Regularly remove dirt and debris from the guide rod and float. The cleaning frequency depends on the medium being monitored.
- Check if the ring buckle is loose and secure it if necessary.
- Keep away from strong acids, alkalis, or solvents when not in use.
5.2. Storage
Store the float switch in a dry and well-ventilated environment, away from direct sunlight.
5.3. Important Notes
- Do not disassemble the sealed reed switch housing. Internal components are not user-serviceable.
- If a malfunction occurs, replace the entire unit.
6. Troubleshooting
- Problem: Switch does not activate at desired liquid level.
- Solution: The float position is fixed and cannot be adjusted. Ensure the switch is installed at the correct height for your application. Verify the liquid level reaches the float's activation point.
- Problem: Connected device (e.g., pump) does not turn on/off, or switch appears to be damaged when controlling high-power loads.
- Solution: The float switch cannot directly control high-power devices. A relay must be used in conjunction with the float switch to handle the load. Refer to the electrical connection section for proper wiring with a relay.
- Problem: Leakage around the mounting point.
- Solution: Ensure the sealing gasket or sealing tape is properly applied and tightened during installation.
7. User Tips & FAQ
User Tips:
- Fixed Float Position: Remember that the float position is fixed. Plan your installation carefully to ensure the switch activates at the desired liquid level.
- Use a Relay for Power Loads: Always use an appropriate relay when connecting the float switch to high-power devices like pumps or alarms to protect the switch and ensure proper operation.
- Customization: If standard dimensions or performance parameters do not meet your needs, custom orders are available. Contact customer support for details.
Frequently Asked Questions:
- Q1: Can the float point be moved?
- A1: No, the float position is fixed and cannot be adjusted.
- Q2: Can the switch directly control water pumps or alarms?
- A2: No, you must add a relay to control high-power devices.
- Q3: What if the required dimensions don’t match the standard sizes?
- A3: Custom dimensions and performance can be ordered in any quantity. Please contact us for custom solutions.
8. Safety and Warning Information (EU Market Reference)
WARNING!
- Risk of electric shock if used with high voltage circuits.
- Disconnect power supply before installation or maintenance.
- Do not exceed rated electrical limits to prevent overheating or fire hazard.
- Ensure proper grounding of associated equipment.
- Keep out of reach of children.
- Proper disposal: Follow WEEE directives for electronic waste.
- This device is not suitable for explosive atmospheres unless additional certified protection measures are implemented.
Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.
9. Warranty and Support
This document is provided for product instruction purposes only and does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations, including CE marking and applicable directives such as the Low Voltage Directive and RoHS.
For technical support, inquiries about custom products, or bulk orders, please contact the seller directly:
- WhatsApp: +86 13311678550
- Email: miazhao008@gmali.com
A detailed user manual in PDF format is also available for download: View User Manual (PDF)
10. Product Video
Watch this video for an overview of the product's manufacturing process and applications.