Hi-Link LD6003G

Contents

Hi-Link LD6003G 60GHz Millimeter Wave Radar Module

User Instruction Manual

1. Product Introduction

The Hi-Link LD6003G is an advanced radar sensing module designed for high-sensitivity human body state detection. It is built around the ADT6101P chip, integrating a 57-64GHz RF transceiver system, 2T2R PCB microstrip antenna, 1MB flash memory, and an ARM® Cortex®-M3 core. This module utilizes FMCW signal processing combined with sophisticated radar signal processing algorithms to accurately identify moving, micro-moving, and stationary human subjects. It also calculates auxiliary information such as target distance and velocity.

Featuring a dual-transmit/dual-receive antenna configuration, the LD6003G offers a wide beam angle, making it ideal for ceiling-mounted installations. It provides GPIO and UART signal outputs for flexible integration into various smart applications and products.

Hi-Link LD6003G 60GHz Millimeter Wave Human Presence Sensing Module

Figure 1: Hi-Link LD6003G 60GHz Millimeter Wave Human Presence Sensing Module

Product Features

  • Radar Detection: Based on FMCW (Frequency Modulated Continuous Wave) signal.
  • Wide Detection Angle: Supports ±60° horizontal and ±60° pitch detection.
  • Sensing Distance: Maximum sensing distance of 6m in top-mounted mode.
  • Target Tracking: Supports up to 3 people for target motion tracking, providing x, y, and z coordinates.
  • Personnel Detection: Detects movement and stillness of indoor personnel, accurately identifies intervals, and supports division of sensing intervals to block interference.
  • Interface: Universal UART interface with communication protocols for parameter adjustment.
  • Compact Size: Measures only 25 × 31.5mm, supporting both pin plug-in and surface mount connection.
  • Environmental Robustness: Unaffected by temperature, humidity, noise, airflow, dust, or light.

2. What's in the Box

The LD6003G module is available in two main configurations:

LD6003G Single Module

LD6003G Single Module

Figure 2: LD6003G Single Module (3D human presence detection + gesture recognition, ≤3 people target tracking, Power supply requirement >1A@3.3V)

LD6003G Test Kit

The test kit includes:

  • LD6003G Module
  • Test Backplane
  • Type-C Cable
LD6003G Test Kit

Figure 3: LD6003G Test Kit Components

3. Setup and Installation

3.1 Power Supply Requirements

  • The module requires a 3.3V power supply.
  • The input current capacity must exceed 1A.
  • Power ripple should be ≤50mV.
  • If a DC-DC power supply is used, the switching frequency must be no less than 2MHz.

3.2 Pin Definitions and Connections

The module features various pins for power, communication, and control. Refer to the table below for detailed pin definitions.

Pin No.Pin NameDescriptionRemarks
GND1GNDGroundSurface mount only
1VDDRFExternal RF Power/1.35V
2WPWrite protection active lowFlash feature foot
3HOLDTo pause the deviceFlash feature foot
4AIO1Temperature index test interfaceAnalog input
5P22GPIO P22/LDO_EXT_EN_H
6TX2GPIO_P20/uart2_txdControl output (e.g., relays)
7RSTReset Signal input
8P19GPIO_P19/boot1Boot
9GNDOGround
10SWDIOSWD Debug Signal
11SWCLKSWD Debug Clock
12P12GPIO_P12/boot0Boot
133.3VPOWER INPUT 3.3V
14GNDGround
15SDAGPIO_P08/IIC0_SDA
16RX0GPIO_P01/uart0_rxd
17TX0GPIO_P00/uart0_txd
18SCLGPIO_P07/IIC0_SCL
19P23IOPAD_P23
20P25IOPAD_P25
21RX1GPIO_P11/uart1_rxd
22TX1GPIO_P10/uart1_txd
23P27IOPAD_P27
24P29IOPAD_P29
25SCLKIOPAD_P03/SPI0_SCLKRF ADC signal acquisition
26MOSIIOPAD_P06/SPI0_MOSIRF ADC signal acquisition
27CSIOPAD_P04/SPI0_CSRF ADC signal acquisition
28MISOIOPAD_P05/SPI0_MISO
29GND1Ground
GND2GNDSurface mount only

3.3 Startup Configuration

The module's startup behavior is controlled by the BOOT1 and BOOT0 pins, which have internal pull-up configurations. For proper operation, BOOT1 must be set to a low level before module startup.

Configuration LevelBOOT1 (Pin 8)BOOT0 (Pin 12)Remarks
Flash Boot0 (Low)1 (High)Flash boot in module

3.4 Installation Methods

The LD6003G module supports both top-mounted and side-mounted installation methods. The optimal sensing range and pattern vary with the installation type.

Top-Mounted Installation

For top-mounted installations, the module is typically placed on the ceiling, looking downwards. The detection range is a conical area below the module. Recommended installation height (H) is between 2.2m and 3m.

Figure 4: Top-Mounted Installation Diagram. The radar module is positioned above, detecting subjects below.

Figure 5: Schematic Diagram of Top-Mounted Detection Range (Polar Plot). Shows a wide, circular detection area.

Side-Mounted Installation

For side-mounted installations, the module is typically placed on a wall. The detection range extends outwards from the module. Recommended installation height is between 1.5m and 2m, with a maximum detection distance of 6m.

Figure 6: Side-Mounted Installation Diagram. The radar module is on the wall, detecting subjects in front.

Figure 7: Side-Mounted Detection Range Diagram (Polar Plot). Shows a wider detection area in front of the module.

4. Operating the Module

4.1 Data Output

  • The HLK-LD6003G module outputs target detection data via its TX2 pin: high level for human presence, low level for absence.
  • UART0 transmits detailed results per protocol, including target position and speed auxiliary information.
  • The output voltage of the module's IO port is 3.3V.
  • The default baud rate for the serial port is 115200, with no parity check.

4.2 GUI Visualization Tools

A Graphical User Interface (GUI) tool is available for visualizing detection data and configuring module parameters.

Device Connection

  1. Set the baud rate of your serial communication software to 115200.
  2. Select the correct serial port number connected to the module.
  3. Click the 'Start' button in the GUI. The module will begin detection and data visualization.

Defining Detection Areas

You can customize up to 4 detection zones to effectively filter out interference and focus on specific areas.

  1. Set detection zone coordinates using the module's vertical projection on the floor as the origin.
  2. Select different zone numbers to define distinct detection areas.
  3. For rooms with wall-mounted air conditioners, you can limit the z-axis range to filter out interference.
  4. Click the 'Set Detection Zone' button to save your settings. The module will still detect outside the zone, but TX2 will only output a high level when triggered within the defined detection range, saving power.

Setting Interference Zones

Interference zones allow you to block out areas with potential interference sources (e.g., air conditioners, fans, curtains). Targets detected in these zones will not trigger the sensor (TX2 will not output a high level). Up to 4 interference zones can be set.

  1. Set interference zone coordinates based on actual usage scenarios.
  2. Click the 'Set Interference Zone' button to save settings.

Other GUI Features

  • Firmware Version: Automatically detected upon GUI connection.
  • Installation Method: Switch between top-side and side-side installation modes.
  • Delay Setting: Maintains presence status for a specified duration after detection.
  • Low-power Mode: Switches to 1T1R mode in unoccupied conditions (average 2.5mA) and 2T2R mode upon motion detection (average 135mA). Sleep duration is adjustable (recommended max 500ms).
  • Point Cloud Display Mode: Enable/disable original point cloud data.
  • Target Display Mode: Show/hide target point data.
  • Detection Sensitivity: Adjust sensitivity levels; low sensitivity detects only motion.
  • Trigger Speed: System detects arrival time with fast (0.5s), medium (1s), and slow (5s) settings.
  • Generate Interference Zone: After installation, in an unoccupied environment, activate interference sources. The radar detects the interference, and clicking this option applies fixed-point shielding.
  • Clear Interference Area: Clears manually set or automatically generated interference areas.
  • Access Settings Area: Access previously set detection and interference areas.
  • Reset Detection Area: Restores the default 4x4m detection area.
  • Z-axis Range Configuration: Defines the overall detection range for the Z-axis (radar position as origin). For a 3m hanging height, set Z-axis min to 0 and max to 3.

4.3 OTA Upgrade

For Over-The-Air (OTA) firmware upgrades, please refer to the dedicated 'Andar OTA Upgrade Tool User Manual_V1.0' document.

5. Maintenance

The Hi-Link LD6003G module is designed for robust and long-term operation with minimal maintenance. Keep the module free from dust and moisture. Ensure proper ventilation if enclosed. No user-serviceable parts are inside.

6. Troubleshooting

  • No Detection/Inconsistent Detection:
    • Verify power supply meets 3.3V and >1A requirements.
    • Check for proper pin connections, especially power and ground.
    • Ensure the module is not obstructed by materials that block 60GHz signals.
    • Review GUI settings for detection zones and interference zones.
    • Adjust detection sensitivity in the GUI.
    • Ensure the installation method (top-mounted/side-mounted) matches the environment and configuration.
  • Communication Issues (UART):
    • Confirm baud rate is set to 115200.
    • Check TX/RX wiring.
    • Ensure the correct serial port is selected in your software/GUI.
  • Module Overheating:
    • Verify power supply voltage is not exceeding 3.5V.
    • Ensure adequate current supply (at least 1A).
    • Provide proper ventilation if the module is enclosed.
  • False Detections:
    • Define interference zones in the GUI to exclude known sources of interference (e.g., fans, air conditioners, curtains).
    • Adjust detection sensitivity.

7. Specifications

7.1 Functional Parameters

Parameter ContentLeast ValueRepresentative ValueCrest ValueUnitRemarks
Longer side of detector0-5mHeight: 2.7 meters
Short edge detection0-3mHeight: 2.7 meters
Detection target--3human being
Range accuracy-0.4-m
Side mounted sensing distance0-6m
Recognition accuracy-95-%

7.2 Electrical Characteristics

Operational ParameterLeast ValueRepresentative ValueCrest ValueUnit
Working Voltage (VCC)3.13.33.5V
Operating Current (ICC)--600mA
Working Temperature (TOP)-20-85°C
Storage Temperature (TST)-40-85°C

7.3 RF Characteristics

Operational ParameterLeast ValueRepresentative ValueCrest ValueUnit
Service Frequency58-64GHz
Output Power (Pout)-12-dBm
Antenna Gain-4-dBi
Horizontal Beam (-3dB)-60-60°
Vertical Beam (-3dB)-60-60°

7.4 External Dimensions

The module's compact design allows for versatile integration.

Product Dimension Diagram

Figure 8: Product Dimension Diagram. Front, Top, and Side views with all measurements in millimeters.

  • Module Dimensions: 25mm (width) x 31.5mm (length)
  • Front Height: 1.6mm
  • Pin Pitch: 2.5mm

8. User Tips

  • For initial setup and testing, using the LD6003G Test Kit can simplify the process significantly.
  • When integrating into custom projects, ensure your power supply is stable and can deliver at least 1A to prevent unexpected behavior.
  • Experiment with different detection sensitivity settings in the GUI to find the optimal balance for your specific application and environment.
  • Utilize the interference zone feature to eliminate false triggers from common household appliances or environmental factors.
  • For ceiling-mounted applications, ensure the module is positioned centrally for the widest coverage.

9. Warranty and Support

For technical support, product inquiries, or warranty information, please contact Hi-Link directly through their official channels. Refer to your purchase documentation for specific warranty terms and conditions.

Video 1: Hi-Link LD6003G Product Overview. This video showcases the physical module and its features.

10. Precautions

  • Detection Range: The effective detection range can fluctuate based on the target's Radar Cross-Section (RCS) and environmental factors. This is a normal phenomenon.
  • Power Supply: Always adhere to the specified power supply requirements (3.1V to 3.5V, ≤50mV ripple, ≥1A current). Using an inadequate power supply can lead to unstable operation or damage.
  • Radome Design: If using a radome (enclosure), ensure it is designed to minimize interference with the radar signal. Materials with lower dielectric constant and loss tangent are preferred. The radome surface should be smooth and of uniform thickness.
  • Electromagnetic Interference: Avoid placing the module near strong electromagnetic interference sources that could affect its performance.
  • Handling: Handle the module with care to prevent physical damage to components or antennas.