1. Overview
The auto range & auto power off clamp multimeter is a portable and stable performance instrument. It features a 6000 counts digit LCD monitor with 16mm high characters. Designed with large-scale IC A/D converters and over-load protection, this meter provides excellent performance and is a handy utility for various electrical measurements.
The 7200B TRMS Clamp Meter can be used to measure:
- DC & AC Voltage
- DC & AC Current
- Resistance
- Capacitance
- Frequency
- Duty Cycle
- Temperature
- Non-Contact AC Voltage (NCV) detection
- Positive Diode Voltage Fall
- Audible Continuity

Figure 1: HoldPeak 7200B TRMS Clamp Meter Features and Dimensions
2. Safety Information
The meter is designed according to IEC-1010 standards, concerning electronic measuring instruments with an over-voltage category 600V (CAT II) and pollution 2. Always follow these safety and operating instructions to ensure safe usage and maintain good operating condition.
2.1 Safety Symbols
- ▲: Important safety information, refer to the operating manual.
- ▲: Dangerous voltage may be present.
- □: Double insulation (protection Class II).
2.2 Special Cautions for Operation
- The meters can only be used according to standard procedures when used in conjunction with the supplied test leads. Replace damaged test leads only with the same model or electric specifications.
- To avoid risk of electric shock, do not use the meters before the cover is in place.
- The range switch should be in the right position for the testing.
- To avoid electric shock and damaging the instruments, input signals are forbidden to exceed the specified limits.
- When measuring TV sets or switched power, pay attention to possible pulses that may damage the circuit.
- Range switch position is forbidden to be changed at random during measurement.
- Take caution against shock when measuring voltage higher than DC 60V & AC 30V.
- Before opening the cover of the battery cabinet to replace batteries, disconnect the test leads from any external circuit, and set the selector switch to the "OFF" position.
- Keep fingers after the protection ring when measuring through the instrument lead or clamp.
- After operation, set the function switch to OFF to save battery power.
- If the meter is unused for a long time, remove the battery to avoid damage from leakage.
3. Product Layout
Familiarize yourself with the components of your clamp meter:

Figure 2: Panel Layout
- Clamp Jaws: Opens 26mm to enclose conductor.
- NCV Detection Area: Located at the bottom.
- Lamp Light: Press the "HOLD" key for over 2 seconds to turn on/off. It also lights up when the built-in buzzer sounds.
- Jaw-Opening Handle: Used to open and close the jaws.
- Rotary Switch: Selects functions and ranges.
- HOLD Key: Locks display value. Press again to exit. Press for >2s for backlight/lamp light.
- SEL Key: Selects modes (resistance, continuity, diode, capacitance, DC/AC voltage/current, C/F temperature). Press and hold to disable Auto Power Off.
- MAX/MIN Key: Locks MAX or MIN value. Press for >2s to exit.
- REL Key: Enters relative measuring mode.
- Hz% Key: Selects Frequency or Duty Cycle measurement.
- LCD Display: 6000 counts digit, full function symbol display.
- COM: Common and Temperature "-" Input Jack.
- VΩ→Hz/T+ Input Jack: Voltage, Resistance, Frequency, Temperature "+" Input Jack.
4. Setup
4.1 Battery Installation
- Ensure the meter is OFF and test leads are disconnected.
- Open the battery cabinet cover using a screwdriver.
- Replace the old battery with two new 1.5V "AAA" R03P batteries, ensuring correct polarity.
- Close the battery cabinet cover and fasten the screw.
4.2 Connecting Test Leads
- For most measurements (voltage, resistance, capacitance, diode, continuity, frequency), connect the black test lead to the COM jack and the red test lead to the VΩ→Hz/T+ input jack.
- For temperature measurements, connect the K-type thermocouple sensor probe to the COM and VΩ→Hz/T+ input jacks.

Figure 3: Connecting Test Leads
5. Operating Instructions
5.1 General Operation
- Rotary Switch: Use to select the desired measurement function (e.g., V~, V-, Ω, Hz, NCV, A~, A-).
- HOLD Key: Press briefly to freeze the current display reading. Press again to release. Press and hold for 2 seconds to activate/deactivate the backlight and lamp light.
- SEL Key: In certain ranges (e.g., Ω, V, A, °C/°F), press to cycle through sub-functions (e.g., resistance, diode, continuity, capacitance; DC/AC; Celsius/Fahrenheit). Press and hold to disable auto power off.
- MAX/MIN Key: Press to capture and display the maximum or minimum reading. Press and hold for 2 seconds to exit.
- REL Key: Press to enter relative measurement mode, setting the current reading as a reference. Press again to exit.
- Hz% Key: In ACV/ACA or Hz range, press to switch between Frequency and Duty Cycle measurement.
5.2 DC & AC Voltage Measurement
- Connect test leads (black to COM, red to VΩ→Hz/T+).
- Set the rotary switch to the desired "V~" (AC Voltage) or "V-" (DC Voltage) range. If in auto-ranging mode, the meter will automatically detect AC or DC. If in a combined range, use the SEL button to switch between AC and DC.
- Connect the test leads across the source or load under measurement.
- Read the voltage value from the LCD. The polarity of the red lead connection will be indicated for DC voltage.
Video 1: Demonstration of AC Voltage (01:10-01:18) and DC Voltage (01:19-01:24) Measurement.
5.3 DC & AC Current Measurement
- Set the rotary switch to the desired "60A~" or "600A~" range position. If in auto-ranging mode, the meter will automatically detect AC or DC. If in a combined range, use the SEL button to switch between AC and DC.
- Press the "REL" key to zero the reading on the display before measurement.
- Clamp the jaws around a single conductor to be measured. Ensure the conductor is centered within the jaws.
- Read the current value from the LCD. The arrow on the jaw indicates the direction of positive current flow (positive to negative).
Video 2: Demonstration of DC Current Measurement.
5.4 Resistance, Diode, Continuity, and Capacitance Measurement
- Connect test leads (black to COM, red to VΩ→Hz/T+).
- Set the rotary switch to the "Ω" range position.
- Press the "SEL" key to cycle through Resistance, Diode, Continuity Test, and Capacitance modes.
- Connect the test leads across the component or circuit under test.
- Read the value from the LCD. For continuity, the buzzer will sound and the lamp light will illuminate if resistance is less than approximately 50Ω.
Video 3: Demonstration of Resistance, Diode, and Continuity Measurement.
5.5 Frequency & Duty Cycle Measurement
- Connect test leads (black to COM, red to VΩ→Hz/T+).
- Set the rotary switch to the "Hz" range position.
- Press the "Hz%" key to switch between Frequency and Duty Cycle measurement.
- Connect the probe across the source or load under measurement.
- Read the value from the LCD.
5.6 Temperature Measurement
- Connect the K-type thermocouple sensor probe (black to COM, red to VΩ→Hz/T+).
- Set the rotary switch to the "°C/°F" range position.
- Press the "SEL" key to select either Celsius (°C) or Fahrenheit (°F).
- Place the sensor probe into the temperature field under measurement.
- Read the temperature value from the LCD.
Video 4: Demonstration of Temperature Measurement.
5.7 Non-Contact AC Voltage (NCV) Detection
- Set the rotary switch to the "NCV" range position.
- Hold the meter so that the bottom of the clamp jaws is vertically and horizontally centered and contacting the conductor.
- When live voltage ≥ 90V AC rms is detected, the lamp light will illuminate and the buzzer will sound.
Video 5: Demonstration of Non-Contact AC Voltage (NCV) Detection.
6. Specifications
Accuracy is specified for a period of one year after calibration and at 18°C to 28°C (64° to 82°F) with relative humidity up to 70%.
6.1 General Specifications
- Max Voltage between input terminal and Earth Ground: CAT II 600V or CAT III 300V
- Over-range Indication: "OL" displayed for significant digit.
- Automatic display of negative polarity: "-"
- Low Battery Indication: "" displayed.
- Max LCD display: 6000 counts digit.
- Auto range control: Yes
- Auto Power Off: After 15 minutes of inactivity, the meter switches to standby mode. Press any key to exit.
- Clamp opening size: 26mm.
- Power supply: 1.5V x 2 "AAA" R03P battery.
- Operating Temp.: 0°C to 40°C (relative humidity <85%)
- Storage Temp.: -10°C to 50°C (relative humidity <85%)
- Guaranteed precision Temp.: 23±5°C (relative humidity <70%)
- Dimension: 207(H) x 75(W) x 37(D)mm.
- Weight: Approx. 280g (including battery).
6.2 Measurement Ranges and Accuracy

Figure 4: Measurement Specifications
| Range | Resolution | Accuracy |
|---|---|---|
| 600mV | 0.1mV | |
| 6V | 1mV | ±(0.5% of rdg + 2 digits) |
| 60V | 10mV | |
| 600V | 100mV | ±(0.8% of rdg + 2 digits) |
Impedance: 10MΩ, >100MΩ on 600mV range. Overload protection: 600V DC or AC rms.
| Range | Resolution | Accuracy |
|---|---|---|
| 6V | 1mV | |
| 60V | 10mV | ±(1.0% of rdg + 3 digits) |
| 600V | 100mV | ±(1.5% of rdg + 3 digits) |
Impedance: 10MΩ. Overload protection: 600V DC or AC rms. Frequency Range: 40 to 2kHz.
| Range | Resolution | Accuracy |
|---|---|---|
| 60A | 10mA | ±(2.5% of rdg + 10 digits) |
| 600A | 100mA |
Overload protection: 600A DC or AC rms.
| Range | Resolution | Accuracy |
|---|---|---|
| 60A | 10mA | ±(2.5% of rdg + 10 digits) |
| 600A | 100mA |
Overload protection: 600A DC or AC rms. Frequency Range: 40 to 100Hz.
| Range | Resolution | Accuracy |
|---|---|---|
| 600Ω | 0.1Ω | ±(1.0% of rdg + 3 digits) |
| 6KΩ | 1Ω | |
| 60KΩ | 10Ω | ±(1.0% of rdg + 2 digits) |
| 600KΩ | 100Ω | |
| 6MΩ | 1KΩ | |
| 60MΩ | 10KΩ | ±(1.5% of rdg + 3 digits) |
Overload protection: 250V DC or AC rms.
| Range | Resolution | Accuracy |
|---|---|---|
| 6nF | 1pF | ±(5.0% of rdg + 10 digits) |
| 60nF | 10pF | |
| 600nF | 100pF | ±(3.0% of rdg + 10 digits) |
| 6µF | 1nF | |
| 60µF | 10nF | ±(5.0% of rdg + 10 digits) |
| 600µF | 100nF | |
| 6mF | 1µF | ±(10.0% of rdg + 20 digits) |
| 60mF | 10µF |
Overload protection: 250V DC or AC rms.
| Range | Resolution | Accuracy |
|---|---|---|
| 9.999Hz | 0.001Hz | |
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999kHz | 1Hz | ±(0.1% of rdg + 5 digits) |
| 99.99kHz | 10Hz | |
| 999.9kHz | 100Hz | |
| 9.999MHz | 1kHz |
Sensitivity: sine wave 0.6V rms (9.999MHz: 1.5V rms). Overload protection: 250V DC or AC rms.
| Range | Accuracy |
|---|---|
| 0.1%~99.9% | ±(2.0% of rdg + 2 digits), Frequency lower than 10kHz |
Sensitivity: sine wave 0.6V rms. Overload protection: 250V DC or AC rms.
| Range | Resolution | Accuracy |
|---|---|---|
| -20-150°C | 1°C | ±(3°C + 1 digit) |
| 150~1000°C | 1°C | ±(3% of rdg + 2 digits) |
| -4-302°F | 1°F | ±(5°F + 2 digits) |
| 302~1832°F | 1°F | ±(3% of rdg + 3 digits) |
NiCr-NiSi K-type sensor. Overload protection: 250V DC or AC rms.
7. Maintenance
- Replace the test leads if the insulation is exposed or damaged. Use only leads with the same specifications as the original.
- Do not use the meter if the back cover is not properly closed and secured with screws. If any abnormality occurs, stop operation immediately and send the meter for maintenance.
- When taking current measurements, keep the cable at the center of the clamp for more accurate results.
- Repairs or servicing not covered in this manual should only be performed by qualified personnel.
- Periodically wipe the case with a dry cloth and detergent. Do not use abrasives or solvents.
- Remove the battery when not using the meter for a long time to prevent leakage.
8. Troubleshooting
- Low Battery Indication: If the "" symbol appears on the LCD, the battery voltage is low and needs to be replaced.
- "OL" Display: If "OL" is displayed, it indicates an over-range situation. Select a higher range if available.
- "EF" Display: During NCV detection, "EF" indicates the presence of an electric field.
- Unstable Readings: For resistance measurements above 1MΩ, the meter may take a few seconds to stabilize.
- No Reading/Incorrect Reading: Ensure test leads are properly connected, the rotary switch is in the correct position, and input signals do not exceed specified limits.
- NCV False Positives: Keep the meter away from electrical noise sources (e.g., fluorescent lights, dimmable lights, motors) during NCV tests, as these can trigger the function.
9. Accessories
The following accessories are included with your HoldPeak 7200B TRMS Clamp Meter:
- Test Leads (electric rating 600V 10A)
- K-type Thermocouple Sensor Probe
- Operator's Manual (this document)

Figure 5: Clamp Meter and Accessories
10. User Tips
- Always double-check the rotary switch position before making any measurement to prevent damage to the meter or the circuit.
- When measuring resistance or capacitance, ensure the circuit under test is de-energized and all capacitors are discharged.
- For accurate current measurements, ensure the conductor is placed centrally within the clamp jaws.
- Utilize the HOLD function to capture stable readings in difficult-to-view locations.
- The MAX/MIN function is useful for monitoring fluctuations in voltage or current over time.
11. Warranty & Support
For warranty information and technical support, please refer to the official seller's documentation or contact the manufacturer directly. An additional user manual in PDF format is available for download: User Manual (PDF).