1. Introduction
The SONGGER R6200 is a 4.3-inch TFT LCD multifunction paperless recorder designed for industrial process monitoring and data logging. It supports up to six isolated universal analog input channels and is compatible with a wide range of temperature, current, voltage, and resistance signals.
This device provides real-time data display, historical trend analysis, USB data export, RS485 communication (Modbus RTU), and configurable relay and analog outputs. It is suitable for industrial automation, process control, environmental monitoring, energy management, and laboratory applications.
2. Specifications
| Feature | Description |
|---|---|
| Power Supply | 220 VAC (50/60 Hz) (Default); optional DC 24V version |
| Material | Industrial-grade enclosure with IP65-rated front panel; keypad with silicone protective layer |
| Size | 160 x 80 mm |
| Panel Cutout Size | 152 x 76 mm |
| Display | 4.3" TFT True Color LCD |
| Input Channels | 1-6 isolated universal analog inputs (optional configuration) |
| Supported Signal Types | Current: 0-10 mA, 0-20 mA, 4-20 mA Voltage: 0-5 V, 1-5 V, 0-20 mV, 0-100 mV Thermocouples: S, B, K, T, E, J, R, N RTD: PT100, CU50, optional PT1000 |
| Output Functions | 1 x 24 VDC sensor power output 2 x relay alarm outputs (default) 2 x analog retransmission outputs Optional: 4-20 mA output and up to 4 relay outputs (Customizable) |
| Communication | RS485 (supports Modbus RTU protocol) |
| Sampling Interval | 1/2/4/8/12/24/36/60/120/180/240 seconds (11 selectable levels) |
| Data Storage | 128 MB internal memory |
| Data Export | USB flash drive (USB 1.1/2.0 compatible, 1 GB-32 GB recommended) |
| Accuracy | ±0.2% of full scale |
| Language | Chinese / English switchable |
3. Setup and Installation
3.1 Preparation
- Ensure the power supply matches the rated voltage of the device (220 VAC or optional 24V DC).
- Prepare a panel cutout of 152 x 76 mm for installation.
3.2 Installation
- Install the recorder into the prepared panel cutout.
- Secure the device firmly within the panel.
3.3 Wiring
Refer to the terminal diagram below for correct wiring connections.
- Connect input signals to the corresponding channel terminals according to the signal type (current, voltage, thermocouple, or RTD).
- Connect RS485 communication lines if integration with a control system is required.
3.4 Precautions during Setup
- Ensure correct wiring before powering on to prevent damage to internal circuits.
- Do not exceed the specified input range for each signal type.
- Use shielded cables for low-level signals (mV, thermocouples, RTDs) to minimize electromagnetic interference.
4. Operation
4.1 Initial Power-On and Configuration
- Power on the device after verifying correct wiring.
- Use the front keypad to enter the configuration menu.
- Set input type, measurement range, alarm thresholds, sampling interval, and communication parameters as required.
- Configure relay outputs and analog retransmission outputs if needed.
4.2 Data Display and Navigation
- The main screen displays real-time values for all active channels.
- Use the navigation keys on the front panel to switch between overview, bar graph, real-time curve, and historical trend display modes.
4.3 Data Export
- Insert a compatible USB flash drive (1-32 GB, FAT format recommended) into the USB port.
- Follow on-screen prompts to export recorded data.
5. Storage and Maintenance
- Keep the device in a dry, dust-free environment when not in use.
- Avoid exposure to corrosive gases or excessive vibration.
- Clean the front panel with a soft, slightly damp cloth. Do not use organic solvents.
- Periodically inspect terminal connections to ensure reliable contact.
- Disconnect power before performing maintenance or rewiring.
6. Troubleshooting
6.1 Common Issues and Solutions
- Device not powering on: Verify that the power supply matches the rated voltage and that all power connections are secure.
- Incorrect readings: Check input signal wiring for proper connection and ensure that the input type and measurement range are correctly configured in the settings. Confirm that shielded cables are used for low-level signals to prevent interference.
- Data export failure: Ensure the USB flash drive is compatible (1-32 GB) and formatted to FAT. Try a different USB drive if issues persist.
- Communication errors: Verify RS485 wiring and communication parameters (e.g., baud rate, parity) are correctly set and match the control system.
7. User Tips
- For industrial applications, installing the recorder in a control cabinet can help ensure reliable real-time data capture and protect the device from environmental factors.
8. Safety Warnings
WARNING! Risk of Electric Shock.
- This device operates at hazardous voltage levels (220 VAC).
- Installation and maintenance must be performed by qualified personnel only.
- Ensure proper grounding of the equipment to reduce the risk of electric shock and electromagnetic interference.
- Do not operate the device in explosive or flammable atmospheres unless additional certified protection measures are implemented.
- Keep out of reach of children.
- This product must be disposed of in accordance with the Waste Electrical and Electronic Equipment (WEEE) Directive. Do not dispose of with household waste.
Note: This warning information is for reference only. Final warning language must comply with the official language requirements of the destination country.
9. Support and Documentation
For further assistance or detailed technical inquiries, please contact the seller or refer to the comprehensive user manual available in PDF format.
A detailed user manual (PDF) is available for download: View User Manual (PDF)