1. Introduction
The MESTEK EMF02R is a digital high-frequency electromagnetic radiometer designed for accurate detection of various electromagnetic radiation types, including electric field radiation and high-frequency radiation from base stations. This instrument features sound and light alarms and a large VA color screen display for clear readings.
1.1. Safety and Security Information
- Read all instructions carefully before using the instrument.
- Ensure the instrument is not damaged before use.
- Store the instrument in a cool, dry place within specified temperature and humidity ranges.
- Discontinue use immediately if any anomaly or damage is observed.
- Avoid direct sunlight, high temperatures, and high humidity environments.
- Clean the instrument with a clean, moist cloth. Do not use corrosive solvents or abrasives.
- Keep away from live contacts or wires during measurement to prevent electric shock.
2. Package Contents
Please check the box for the following items:
- 1 x MESTEK EMF02R High Frequency Radiation Detector
- 1 x USB Type-C Charging Cable
- 1 x Product Manual (this document)
- 1 x Cloth Bag

3. Device Layout

3.1. Components
- Induction Probe: Top part of the device for signal detection (X, Y, Z axes).
- Display Screen: VA reverse display color screen for readings.
- Function Keys: Buttons for various operations.
- Charging Indicator Light: LED to show charging status.
- Type-C Charging Port: For connecting the USB Type-C charging cable.
3.2. Function Keys

| Symbol | Description |
|---|---|
| ⏻ | Power button (On/Off) |
| SEL | Function conversion key (E-field, H-field) |
| AVG/MAX | Average and maximum value conversion keys |
| HOLD | Data lock key |
| 🔔 | Ring tone on/off key (Buzzer) |
| RF | High frequency signal conversion key |
4. Setup
4.1. Charging the Device
The EMF02R is powered by a built-in 18650/2000mAh/3.7V lithium battery. Before first use, or when the battery indicator shows low power, charge the device.

- Connect the supplied USB Type-C cable to the charging port on the bottom of the device and to a 5V/1A USB power adapter (not included).
- Ensure the charging environment is well-ventilated and allows for heat dissipation.
- The charging indicator light will be red during charging.
- When fully charged (approximately 4 hours), the indicator light will turn green.
- The instrument will automatically shut down during charging and cannot be operated. It can be used normally once charging is complete and the cable is disconnected.
- If the battery indicator on the screen flashes, it indicates low battery; please charge the instrument as soon as possible.
5. Operating Instructions
5.1. Power On/Off
- To Power On: Long press the ⏻ (Power) button.
- To Power Off: Long press the ⏻ (Power) button again.
5.2. Measurement Modes

- RF (High Frequency) Measurement:
Short press the RF button. The screen will display "RF". This mode measures high-frequency signal radiation from base stations between 30MHz and 8GHz. - E-field (Electric Field) Measurement:
Short press the SEL key until "E-field" is displayed. This mode measures the electric field radiation values of electrical equipment. - H-field (Magnetic Field) Measurement:
Short press the SEL key until "H-field" is displayed. This mode measures electromagnetic field radiation. Short press SEL again to convert the measurement units between mG (MilliGauss) and uT (Micro Tesla).
5.3. Data Lock (HOLD)
- Short press the HOLD button to lock the current reading on the screen.
- Press HOLD again to unlock and resume real-time measurement.
5.4. Average (AVG) and Maximum (MAX) Values
- Short press the AVG/MAX button to cycle through displaying the average value (AVG) and the maximum value (MAX) detected during the measurement session.
5.5. Buzzer (Ring Tone)
- Short press the 🔔 (Buzzer) button to turn the audible alarm on or off.
- When the alarm sounds (audible and analog display reaches yellow/red area), it indicates excessive radiation. Take protective measures or move away from the source.
- Long press the 🔔 (Buzzer) button to switch between Celsius (℃) and Fahrenheit (℉) for temperature display.
5.6. Automatic Shutdown
- The instrument features an automatic shutdown function after approximately 15 minutes of inactivity to conserve battery.
- To Cancel Automatic Shutdown: While the unit is powered off, press and hold the HOLD button, then press the ⏻ (Power) button. Release both keys when the screen lights up and the auto shutdown symbol (a small clock icon) in the upper left corner of the display disappears.
- To restore the auto shutdown function, power off the device and power it on normally.
6. Screen Display

| Symbol | Description | Unit | Meaning |
|---|---|---|---|
| ⏻ | Power | Power On/Off indicator | |
| 🔋 | Battery Indicator | Battery level status | |
| ⏰ | Automatic shutdown | Auto power-off active | |
| ███ | Simulated display | Analog bar graph of radiation level | |
| AVG | Average value | Average reading | |
| MAX | Maximum value | Peak reading | |
| HOLD | Data locking | Reading is frozen | |
| RF | Radio frequency | High-frequency measurement mode | |
| H-field | Magnetic field | Magnetic field measurement mode | |
| E-field | Electric field | Electric field measurement mode | |
| uT | Micro Teslas | uT | Unit for magnetic field strength |
| mG | MilliGauss | mG | Unit for magnetic field strength |
| V/m | Volts per meter | V/m | Unit for electric field strength |
| uW/cm² | Microwatt/square centimeter | uW/cm² | Unit for power density |
| ℃ | Celsius | ℃ | Temperature unit |
| ℉ | Fahrenheit degree | ℉ | Temperature unit |
| % | Percentage | % | Relative Humidity unit |
| 🔔 | Ringtones | Buzzer status |
6.1. Radiation Level Interpretation (Analog Display)

| Unit | Green (Low) | Yellow (Medium) | Red (High) |
|---|---|---|---|
| uW/cm² | 0.0 - 39.9 | 40 - 99.9 | 100 - 9999 |
| V/m | 0 - 39 | 40 - 399 | 400 - 999 |
| mG | 0.0 - 3.9 | 4.0 - 39.9 | 40.0 - 199.9 |
| uT | 0.00 - 0.39 | 0.40 - 3.99 | 4.00 - 19.99 |
7. Maintenance
7.1. Cleaning
- Ensure the device is powered off and disconnected from any power source before cleaning.
- Wipe the instrument with a clean, moist cloth.
- Do not use corrosive solvents, abrasive cleaners, or immerse the device in water.
7.2. Storage
- Store the instrument in a cool, dry place.
- Keep within the specified storage temperature and humidity range: -10~60℃ / 0~80% RH.
- Use the provided cloth bag for protection when not in use.
8. Troubleshooting
- Device not turning on: Ensure the battery is charged. Connect to a charger for at least 30 minutes.
- Low battery indication: If the battery icon flashes, charge the device immediately.
- Instrument shuts down during charging: This is normal behavior; the device cannot be operated while charging.
- No readings/Erratic readings: Ensure the induction probe is clear of obstructions. Try restarting the device.
- Alarm sounds frequently: This indicates high radiation levels. Refer to the "Radiation Level Interpretation" table (Section 6.1) and take appropriate protective measures or move away from the source.
9. Specifications

| Parameter | Value |
|---|---|
| Working Height | 2000m |
| Measurement Method | Electromagnetic induction, RF radio frequency receiving sensor |
| Display Screen | VA reverse color screen |
| Maximum Display | 9999 |
| Sampling Rate | About 0.4 seconds |
| Measuring Range | V/m: 0~999 / uT: 0.00~19.99 / mG: 0.0~199.9 / uW/cm²: 0.0~9999 |
| Test Bandwidth | 30MHz~8GHz |
| Resolving Power | V/m: 1 / uT: 0.01 / mG: 0.1 / uW/cm²: 0.1 / 0.1℃ / 0.2℉ / 1%RH |
| Alarm Method | Sound, simulation bar |
| Automatic Shutdown | About 15 minutes |
| Working Current | Approximately 50mA |
| Charging Interface | USB Type-C |
| USB Charging | 5V/1A |
| Power Source | Built-in 18650 / 2000mA / 3.7V lithium battery |
| Charging Time | About 4 hours |
| Temperature Measurement Range | 0~50℃ |
| Humidity Measurement Range | 0~90% RH |
| Working Temperature and Humidity | 0~50℃ / 0~90% RH |
| Storage Temperature and Humidity | -10~60℃ / 0~80% RH |
| Size | 204 x 63 x 32mm |
| Weight | Approximately 220g |
10. User Tips
- For best results, perform measurements in different orientations (rotate the device) to capture radiation from various angles, especially when using the triaxial probe.
- When investigating potential radiation sources, move the device slowly towards the suspected source to pinpoint the area of highest emission.
- Always observe the analog bar graph and the numerical display together for a comprehensive understanding of radiation levels.
- Keep the device charged to ensure it's ready for use, especially for prolonged monitoring sessions.
11. Warranty and Support
For detailed warranty information, technical support, and service inquiries, please refer to the official product documentation or contact your point of purchase. A PDF version of the user manual may be available for download at the seller's website or via the provided link: View User Manual (PDF).