1. Introduction
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your SLyric Professional Diode Laser Hair Removal Machine. This advanced device is designed for permanent hair removal, skin whitening, and skin rejuvenation, utilizing Alexandrite Ice Platinum Laser technology with multiple wavelengths. Please read this manual thoroughly before operating the machine and keep it for future reference.
2. Safety Information
Operating a professional laser epilator requires adherence to strict safety protocols to prevent injury to both the operator and the client. Always ensure the following:
- Only trained and certified professionals should operate this equipment.
- Wear appropriate laser safety eyewear during operation.
- Ensure the treatment area is clean and free of any topical creams or lotions.
- Do not operate the machine if any part is damaged or malfunctioning.
- Keep the device away from water and extreme temperatures.
- Familiarize yourself with the emergency stop switch location and function.
For a comprehensive understanding of safety procedures, please refer to the full user manual available from the seller.
Important Note: The full user manual (PDF) is available. For detailed safety guidelines and operational procedures, please contact the seller directly.
3. Product Overview
The SLyric Professional Diode Laser Hair Removal Machine is a high-power device featuring a user-friendly interface and an ergonomic handpiece. It incorporates advanced cooling systems for comfortable and effective treatments.
3.1 Components
- Main Unit with Touch Screen Display
- Laser Handpiece
- Handpiece Holder
- Power Cable
- Key Switch
- Emergency Stop Switch
3.2 Visual Reference




4. Specifications
| Attribute | Value |
|---|---|
| Brand Name | SLyric |
| Item Type | Epilator |
| Epilator Type | Laser |
| Power Type | Electric |
| Power Source | Electric |
| Voltage | 220V (110V options available) |
| Use Area | BODY |
| Product Name | 808 Laser Diode Hair Removal Machine |
| Key Word | diode laser 755 808 1064 |
| Wavelength | 808nm / 755nm / 1064nm (3 wave) |
| Cooling System | Air + Water Cooling + Semiconductor |
| Feature | Permanent painless hair removal, Whitening, Skin Rejuvenation |
| Application | For Commercial, Beauty Center & Clinic |
| Certification | CE, RoHS |
| Origin | Mainland China |
| High-concerned chemical | None |
5. Setup
Before operating the SLyric Diode Laser Machine, ensure proper setup:
- Unpacking: Carefully remove all components from the packaging. Inspect for any damage during transit.
- Placement: Place the main unit on a stable, flat surface in a well-ventilated area. Ensure adequate space around the machine for air circulation.
- Handpiece Connection: Connect the laser handpiece securely to the designated port on the main unit. Ensure the connection is firm to prevent leakage or malfunction.
- Power Connection: Connect the power cable to the machine and then to a suitable electrical outlet (ensure voltage matches machine requirements, either 110V or 220V depending on your model).
- Water Filling (if applicable): If your model requires water cooling, follow the instructions in the comprehensive manual to fill the water tank with distilled water.
- Key Insertion: Insert the key into the key switch and turn it to the 'ON' position.
- Emergency Stop: Ensure the emergency stop button is disengaged (pulled out).
6. Operating Instructions
The SLyric Diode Laser Machine features an intuitive touch screen interface for easy operation. The following steps outline the general operating procedure:
- Power On: Turn the key switch to the 'ON' position. The machine will power up, and the touch screen display will activate.
- System Initialization: Allow the system to initialize. The screen will display the main operating interface.
- Select Treatment Area: On the touch screen, select the desired treatment area (e.g., body, face) from the anatomical diagrams.
- Adjust Parameters: Based on the client's skin type, hair color, and treatment area, adjust the following parameters on the screen: Fluence (energy density), Pulse Width, and Frequency. The system may offer recommended settings.
- Prepare Handpiece: Remove the handpiece from its holder. Ensure the cooling tip is clean and cold.
- Start Treatment: Press the 'Start' button on the screen to enable the laser.
- Apply Handpiece: Place the handpiece firmly against the skin in the treatment area.
- Deliver Pulses: Press the trigger button on the handpiece to deliver laser pulses. Move the handpiece smoothly across the treatment area.
- Monitor Cooling: The handpiece features an advanced cooling system (Alexandrite Ice Platinum) to ensure client comfort. Monitor the cooling effect during treatment.
- Pause/Stop: To pause treatment, release the handpiece trigger. To stop the session, press the 'Stop' button on the screen. In case of emergency, press the red emergency stop switch.
- Power Off: After completing all treatments, turn the key switch to the 'OFF' position and disconnect the power cable.
6.1 Operation Demonstration
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your SLyric Diode Laser Machine.
- Cleaning: Regularly clean the exterior of the machine and the handpiece with a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Handpiece Care: After each use, clean the handpiece tip thoroughly. Ensure no gel or debris remains.
- Water System: If applicable, regularly check and replace the distilled water in the cooling system as per the full manual's recommendations.
- Filter Cleaning: Periodically clean or replace air filters to ensure efficient cooling. Refer to the full manual for specific instructions.
- Storage: When not in use, store the machine in a clean, dry environment, away from direct sunlight and extreme temperatures. Place the handpiece securely in its holder.
8. Troubleshooting
If you encounter any issues with your SLyric Diode Laser Machine, refer to the following common troubleshooting steps:
- Machine Not Powering On:
- Check if the power cable is securely connected.
- Ensure the key switch is in the 'ON' position.
- Verify that the emergency stop button is disengaged.
- Check the power outlet for functionality.
- Laser Not Firing:
- Ensure the 'Start' button on the screen has been pressed.
- Check if the handpiece is properly connected.
- Verify that the parameters are set correctly and within safe operating ranges.
- Ensure the handpiece is in firm contact with the skin.
- Insufficient Cooling:
- Check the water level in the cooling system (if applicable).
- Ensure air vents are not obstructed.
- Contact support if the issue persists.
For more complex issues or if troubleshooting steps do not resolve the problem, please contact customer support.
9. User Tips
To maximize the effectiveness and safety of your laser hair removal treatments, consider these tips:
- Skin Preparation: Ensure the treatment area is shaved, clean, and dry before each session. Avoid waxing or plucking hair for several weeks prior to treatment, as the laser targets the hair follicle.
- Cooling Gel: Apply a thin layer of cooling gel to the treatment area to enhance comfort and optimize laser penetration.
- Patch Test: Always perform a patch test on a small, inconspicuous area of skin before a full treatment to assess skin reaction and determine optimal settings.
- Post-Treatment Care: Advise clients to avoid direct sun exposure and use sunscreen on treated areas. Soothing lotions can be applied if needed.
- Consistent Sessions: Multiple sessions are required for permanent hair reduction, typically spaced several weeks apart, to target hair in different growth cycles.
10. Warranty and Support
Your SLyric Professional Diode Laser Hair Removal Machine comes with comprehensive support services:
- After-sales Service: Free spare parts, online support, and video technical support are provided.
- Our Service: Enjoy 24 hours online service and instructional operation video training.
- Language: The system supports English by default, with options for customized languages.
For any warranty claims or technical assistance, please contact the seller or manufacturer directly with your product model and purchase details.