1. Safety Information
Warning: To avoid danger of suffocation, keep this bag away from babies and children. Do not use this bag in cribs, beds, carriages, or play pens. This bag is not a toy.
General Precautions
- After receiving the product, please have an electrical professional perform the operation.
- Connect the equipment in accordance with the wiring diagram specifications.
- According to the instructions, adjust the equipment parameters.
- Do not place the device near flammable materials.
- Ensure adequate ventilation during operation.
- Disconnect from power and store properly when not in use for extended periods.
2. Product Overview
The TOMZN TOQ9-63/2P is a compact, PC-grade dual-power automatic transfer switch (ATS) designed for household AC distribution systems (50/60Hz, 10-80A). It automatically switches the load to a backup power supply when the main power supply fails and switches back when the main power is restored. This model features a slim design, reducing size and weight compared to previous generations.
Key Features and Characteristics:
- Millisecond Switching: Utilizes an excitation-type electromagnetic drive mechanism for extremely fast transfer, typically less than 50ms, ensuring uninterrupted power.
- Automatic Operation: Automatically transfers load to backup power upon main power failure and retransfers to main power when restored.
- Dual Interlock Mechanism: Incorporates mechanical and electrical interlocks to prevent simultaneous closure of both power sources.
- Voltage Detection: Includes under/over-voltage detection. For AC 220V, it transfers if voltage is below 175V or above 275V.
- Visual Indicators: Features illuminated indicators for Normal Power Source (I), Alternate Power Source (II), and Load ON for clear operational status.
- Modular Design: Compact unit with same-side terminal configuration for simplified wiring, mounting, and maintenance.
- Arc-Extinguishing System: Integrated system splits arcs into multiple series segments within the arc chute, enhancing safety and durability.
- Durable Construction: Encased in fire-resistant housing (UL94 V-0 rated) with conformal-coated PCBs (IPC-CC-830B compliant) for flame resistance and environmental durability.
- Industrial Silver Contacts: Improves service life and conductive performance.
Figure 1: Front view of the TOQ9-63/2P ATS with indicators and controls.
Figure 2: Perspective view of the TOQ9-63/2P ATS.
Figure 3: Industrial silver contacts for enhanced durability and conductivity.
3. Specifications
Key Technical Parameters
| Parameter | Value |
|---|---|
| Brand | TOMZN |
| Model Number | TOQ9-63/2P |
| Type | Mini Circuit Breaker, Dual Power Automatic Transfer Switch |
| Poles Number | 2P |
| Rated Current (In) | 63A |
| Rated Voltage (Ue) | AC220V (L+N 220-240V) |
| Rated Insulation Voltage (Ui) | 690V |
| Rated Impulse Withstand Voltage (Uimp) | 8kV |
| Rated Frequency | 50/60Hz |
| Transfer Action Time | <50ms (typically 20ms) |
| Mechanical Life | ≥5000 Times |
| Electrical Life | ≥1500 Times |
| Utilization Category | AC-31B |
| Rated Short-Circuit Current (Iq) | 50kA |
| Short Circuit Protection Device (Fuse) | RT 16-00-63A |
| Rated Control Voltage (Us) | AC220V 50Hz (Normal working conditions: 85%Us-110%Us) |
| Auxiliary Circuit | AC220V 50Hz le=5A |
| Operational Ambient Temperature | -5°C to +40°C (24-hour average +35°C) |
| Storage Temperature | -25°C to +55°C (transient peaks up to +70°C within 24 hours) |
| Installation Altitude | ≤2,000 meters above sea level |
| Relative Humidity | ≤50% at +40°C (up to 90% at +20°C) |
| Pollution Degree | 3 |
| Enclosure Rating | IP30 |
Dimensions
Figure 4: Dimension Diagram (Approx. 110mm H x 50mm W x 78mm D).
Figure 5: Side view with printed specifications.
4. Setup and Installation
Installation should only be performed by a qualified electrical professional.
Mounting Method
The TOQ9-63/2P is designed for 35mm standard DIN rail installation. It can be directly installed on household lighting distribution boxes.
Figure 6: 35mm Standard DIN Rail Installation.
Wiring Instructions
Connect the equipment in accordance with the wiring diagram specifications. Ensure all connections are secure.
- When power line input through the L and N, please screw down to penetrate the insulating layer of the power lines.
- The device works with L+N 220-240V 50-60Hz.
- Integrated power sampling lines eliminate the need for external control wiring, enabling automatic transfer functionality upon completion of main circuit connections.
Figure 7: Easy Wiring Diagram. Connect Backup Power Supply (L, N), Common Power Supply (L, N), and Load.
Video 1: Demonstration of the TOMZN ATS installation and operation in a panel.
5. Operating Instructions
The TOQ9-63/2P offers both automatic and manual operation modes.
Mode Selection
Figure 8: Manual Handle and Manual/Automatic Switch.
- Manual Mode: To manually operate the switch, the mode selector must first be set to the "Manual" position. You can then use the manual handle to switch between Source I and Source II.
- Automatic Mode: Set the toggle switch to the "Auto" position. In this mode, the device will automatically switch between power sources based on availability and voltage conditions.
Automatic Switching Logic
- When the main power supply (Source I) of the circuit fails (e.g., phase loss, voltage below 175V, or above 275V for AC 220V systems), the equipment will immediately switch to the backup power supply (Source II), provided Source II voltage is within the acceptable range (187V-253V).
- After the regular power supply (Source I) returns to normal (within 187V-253V range), the switch automatically retransfers to Source I after a 30-second delay.
Figure 9: Automatic switching after power off in less than 50ms.
6. Maintenance
Before performing any maintenance or inspection, all external power sources must be disconnected. Work must be carried out exclusively by qualified personnel.
Inspection Schedule
- Initial Inspection: Within six months after installation.
- Subsequent Inspections: At least annually. In demanding conditions, increase the frequency of maintenance and inspection.
Maintenance Items
- Promptly remove dust and dirt to prevent malfunctions.
- Visually inspect the electrical contact areas for deformation or damage. Clean off any metal particles and arc marks from the contact surfaces and surrounding areas.
- Rust, oxidation, or dust accumulation on contact surfaces may cause poor electrical contact. Manually operate the ATS several times and measure contact resistance if necessary.
- If the ATS has been slightly dampened or remains idle for an extended period, it must be dried before energizing. After removing dust and contaminants, measure the insulation resistance using a 500V megohmmeter (megger) between Normal/Standby/Load terminals, across poles, and between all live parts and mounting rails. The ATS shall only be energized when insulation resistance measures no lower than 10MΩ.
7. Troubleshooting
While the TOMZN TOQ9-63/2P is designed for reliable operation, here are some common issues and troubleshooting steps:
- No Automatic Transfer:
- Ensure the switch is set to the "Auto" position.
- Verify that both Source I and Source II are providing power within the specified voltage ranges.
- Check for any loose wiring connections.
- Poor Electrical Contact:
- Dust, dirt, rust, or oxidation on contact surfaces can cause poor electrical contact. Refer to the maintenance section for cleaning procedures.
- Manually operate the switch several times to help clear minor contact issues.
- Device Not Responding:
- Ensure all power sources are connected and active.
- If the device has been exposed to damp conditions or idle for a long time, ensure it is thoroughly dried before re-energizing.
- Perform an insulation resistance test as described in the maintenance section.
For persistent issues, consult a qualified electrical professional.
8. User Tips
- Space-Saving Design: The slim model is ideal for installations where space is a concern, fitting well into standard distribution boxes.
- Household Use: The 63A current rating is generally sufficient for typical household loads, providing reliable power transfer.
- Inspect Upon Arrival: Always inspect the product and its packaging upon receipt for any damage, especially the DIN rail clip, which is essential for secure mounting.
- Professional Installation: For safety and optimal performance, always have a qualified electrician install the ATS.
9. Applicable Regulations and Harmonized Standards
This product complies with the following directives:
- Low Voltage Directive (LVD) 2014/35/EU
- Electromagnetic Compatibility (EMC) Directive 2014/30/EU
- Restriction of the Use of Certain Hazardous Substances (RoHS) Directive 2011/65/EU
- CE Certified
For detailed compliance documentation, including the EU Declaration of Conformity, please contact TOMZN customer support.
10. Warranty and Support
For warranty information, technical support, or to inquire about replacement parts, please contact the TOMZN Official Store or your authorized dealer. Ensure you have your product model number (TOQ9-63/2P) and purchase details available when seeking support.
11. Additional Resources
A detailed user manual in PDF format is available for download: