1. General Information
The MYOSlim Neo Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
1.1 Indications for Use
The EMS Body Sculpt is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of a fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.4 Description of the Device
The EMSZERO enables a simple and effective treatment process. You can easily perform this by adjusting the digital energy selection treatment plan or diagnostic procedure. Any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.
1.5 Contraindications
Do not use this device if any of the following apply:
- Wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during the menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
2. Safety Precautions and Warnings
Precautions to observe before using the device:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest intensity level and then increase it sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Try to eat after one hour after the operation.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
The main unit features a display screen, EMS handles, and an On/OFF button on the front. The rear panel includes the handle connection ports, a main power switch, and a power plug input.
Note: The handle can only be used by the original machine and cannot be used interchangeably.
3.2 Handle Types
The device comes with various handles and optional accessories:
- Standard Handles (2 pieces)
- Cushion (optional accessory)
Image: Cushion handle, an optional accessory for specific treatment areas.
3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host Machine | 1 set | ![]() |
| 2 | Handles (various types) | 2-4 (depending on model) | ![]() |
| 3 | Belts (8*80CM, 8*90CM, 8*100CM) | 3 | |
| 4 | Power cable | 1 | |
| 5 | Electronic manual | 1 copy |
4. Device Installation and Setup
Follow these steps to install and set up your MYOSlim Neo machine:
4.1 Install the Handle Bracket
- Using a screwdriver, install the handle brackets on both sides of the main unit.
4.2 Handle Film Application
- Apply the black film to the working part of the handle.
4.3 Installing the Handle
- Align the handle with the hole on the machine and fasten the clip.
- Lock the key ring to secure the handle.
4.4 Connect Power
- Connect one end of the power cord to the machine and plug the other end into the socket.
- Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.
4.5 Powering On/Off
- Press on the back switch: Locate the manual switch on the rear panel and move it to the "I" (on) position.
- Press the front switch: Single-click the power button on the front panel to turn on the machine.
- To turn off, long-press the power button on the front panel.
Video: Demonstrates connecting the power cord, turning on the machine, adjusting settings on the touch screen, and attaching handles to the body for treatment.
5. Basic Device Operation
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "I" (on) position.
- Press the power button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays various items and functions:
- Navigation controls (List, Pattern, Records)
- Channels selector
- Stop therapy button
- Start/pause therapy button
- Setting up therapy parameters (Time, Energy, Frequency)
5.4 Unit Settings
The machine offers two main operating modes, Mode 1 and Mode 2, each with adjustable parameters.
Mode 1 Operation:
The operation interface of Mode 1 allows you to adjust the part, age, and gender where the machine needs to be used. You can adjust these settings according to your specific needs. The frequency range for Mode 1 is 5-60Hz.
To begin, select Mode 1. You can then adjust the part of the body for treatment (e.g., abdomen, buttocks), the age group, and gender. After setting these parameters, click the start button.
Mode 2 Operation:
In Mode 2, you can adjust the energy to your needs and the energy size according to your own body system. The frequency range for Mode 2 is 30-100Hz.
Select Mode 2. You can then adjust the energy percentage (e.g., 20%, 30%), the frequency (e.g., 60Hz, 110Hz, 140Hz), and the time (e.g., 30 minutes). This mode also features 3 different periods of frequency for free adjustment.
Note on Adjustments:
- Adjust the corresponding intensity/stage frequency/time according to different customer needs. Click the start/pause work button to enter the operation work.
- If the customer requests to pause, they can click the start/pause work button to pause the work.
- After the work is completed, you can directly click the return key to return.
6. Therapy
6.1 Preparing the Therapy
- Communicate with patients.
- Ensure good health.
- Stay hydrated.
- Wear appropriate clothing.
- Avoid eating in large quantities.
- Be familiar with the treatment process.
- Avoid drinking alcohol.
6.2 Placing the Handle
The handles should be placed securely on the target body part using the provided straps. Ensure a snug fit for effective treatment.
- Belly: Use a strap to tie the large handle to the abdomen.
- Buttock: Secure the handle to the buttock area with a strap.
- Arm: Attach the handle to the arm using a strap.
- Thigh: Use a strap to tie the small handle to the thigh.
- Calf: Secure the small handle to the calf with a strap.
- Arse (Pelvic Floor Muscles): The cushion handle is specifically designed for repairing pelvic floor muscles.
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
6. Maintenance
6.1 Daily Inspection
Regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
6.2 Cleaning
6.2.1 Cleaning the Surface of the Device
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. The logo of the machine is painted by a silk screen printing process. The rest of the parts are painted with a spray painting technique. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.
6.2.2 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
6.3 Fuse Replacement
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. When replacing the fuse, to prevent electric shock, please turn off the power and unplug the power plug.
6.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, the relative humidity should not be greater than 93%, and it is not allowed to be placed in harmful gases, around flammable, explosive substances, and corrosive gases.
Transportation: The instrument under the packaging condition is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, it should prevent severe vibration and shock, and should not be affected by moisture, and should not be mixed with flammable and corrosive substances. Specific requirements are specified in the order contract.
7. Troubleshooting
Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection | Reseat the handle |
8. Technical Specifications
| Attribute | Value |
|---|---|
| Model | E-10 |
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Technology | HIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting |
| Product Name | Body Sculpt Machine, E HIEMT Body Slimming Sculpting Machine |
| Power Supply | Alternating Current |
| Voltage | AC220V/50Hz AC110V/60Hz (50-1000V AC) |
| Power Output | 0-6500W |
| Frequency | 0-200HZ (5-200HZ) |
| Screen Size | 10.4 inches |
| Material | ABS & TPR |
| Certification | CE, RoHS |
| Handles | 4/5 handles (depending on model) |
| Usage Time | Three times a week, 30-40 minutes each time. |
| Language | English, Spanish, Portuguese, Chinese, French, Russian and other 8 languages |
| Origin | Mainland China |
8.1 Electromagnetic Compatibility (EMC)
The device has undergone Radiated Electromagnetic Field Immunity Testing according to IEC 61000-4-3:2020 standards. The test level was 30V/m with 80% AM, 1kHz Modulation. The test setup involved a 7x4x3 meter chamber with the Equipment Under Test (EUT) and support, monitored by a camera in a contro room. This ensures the device's stable operation in various electromagnetic environments.
9. Warranty and Support
9.1 Warranty Card
The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance.
The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates may incur appropriate fees. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year.
Free warranty service is not provided for the following user's failures caused by personal reasons:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this instruction manual.
For detailed warranty information and to record maintenance, please refer to the full user manual (PDF) available at: User manual (PDF)
9.2 After-sales Service
After the warranty period has expired, please contact the manufacturer directly to provide paid after-sales service. To repair the machine, you must contact the company's business department or dealer, and do not repair it without authorization. Any unpacking without consent will not be guaranteed by our company.
After-sales service includes video technical support and online support.
10. User Tips
While no specific user reviews or Q&A were provided for this manual, general tips for using body sculpting machines often include:
- Consistency is Key: For best results, adhere to the recommended usage schedule (e.g., three times a week, 30-40 minutes each time).
- Stay Hydrated: Drink plenty of water before and after sessions to support your body's metabolic processes.
- Listen to Your Body: Start with lower intensity and gradually increase as your body adapts. If you experience discomfort, reduce the intensity or stop the session.
- Proper Placement: Ensure handles are securely and correctly placed on the target areas as shown in the therapy section to maximize effectiveness and safety.
- Combine with Healthy Lifestyle: For optimal fat reduction and muscle building, combine device usage with a balanced diet and regular exercise.
11. Manufacturer