MYOSLIM EMS Body Sculpt

Contents

MYOSLIM EMS Body Sculpt Machine User Manual

Model: EMS Body Sculpt

1. General Information

The MYOSLIM EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions. This technology promotes muscle growth and reshapes the internal structure of muscles. Additionally, it triggers significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

Advanced HI-EMT Technology

The EMS Body Sculpt series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.

Touch-Controlled Display

The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.

Real-time Monitoring and Guidance

Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.

Upgradeability

As your therapeutic needs evolve, the EMS Body Sculpt series offers flexible upgrade options to meet your future treatment requirements.

Indications for Use

The EMS Body Sculpt is intended for:

  1. Improvement of abdominal tone, strengthening of the abdominal muscles, development of a fitter abdomen.
  2. Strengthening, toning, and firming of buttocks, thighs, and calves.
  3. Improvement of muscle tone and firmness, for strengthening muscles in arms.

2. Important Safety Instructions

DANGER

Risk of electric shock. Do not open the device casing. No user-serviceable parts inside. Refer servicing to qualified personnel only.

CAUTION

  • This device is for adult use only. Do not use on minors or individuals without a health clearance certificate.
  • Do not use if you have metal implants, heart disease (such as those with arrhythmias), especially those with pacemakers.
  • Remove all metal jewelry before operation. Avoid contact with open wounds.
  • Do not use on a full stomach. Allow at least 1 hour after meals and refrain from eating/drinking during and 1 hour post-treatment.
  • Never replace the treatment handle while the device is powered on. Always turn off the power and calibrate the handle before replacement.
  • Keep away from strong electromagnetic sources. Do not daisy-chain multiple devices on a single power outlet.
  • This product is intended to be used in dry areas only.

Contraindications

  • Wounds on the skin (or avoiding wounds when using);
  • Patients with heart disease (such as those with arrhythmias), especially those with pacemakers;
  • Cancer patients;
  • Patients with infectious diseases;
  • Pregnant women, lactating women, menstrual period;
  • Major surgery patients, diabetic patients;
  • Having any metal in the body;
  • People with cerebrovascular disease (stroke patients).

Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

CE Mark: This symbol stands for "European Conformity", which declares conformity with all relevant EU health, safety and environmental protection regulations.

3. Setup and Initial Operation

Operating Environment

The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.

  • Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
  • Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
  • Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
  • Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
  • Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
  • Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.

Device Start-up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

EMS Body Sculpt machine with two large handles for body, abdomen, buttocks and two smaller handles for arms, thighs.
The EMS Body Sculpt machine comes with two large handles for body, abdomen, and buttocks, and two smaller handles for arms and thighs.

4. Operating the Machine

Preparing for Therapy

  1. Communicate with patients.
  2. Ensure good health.
  3. Stay hydrated.
  4. Wear appropriate clothing.
  5. Avoid eating in large quantities.
  6. Familiarize yourself with the treatment process.
  7. Avoid drinking alcohol.

Placing the Handle

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.

Diagram showing handle placement for various body parts: Belly, Buttock, Arm, Thigh, Calf, and Arse.
Proper handle placement for different body areas: Belly, Buttock, Arm, Thigh, Calf, and Arse.

Setting the Therapy by Controls

Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

Close-up of the EMS Body Sculpt machine's touch screen interface showing treatment parameters and controls.
The touch screen interface allows for setting treatment parameters such as intensity and time.

The main controls include:

  • Navigation controls: For moving through menus.
  • Channels selector: To choose which handles are active.
  • Stop therapy: To immediately halt the treatment.
  • Start/pause therapy: To begin or temporarily stop the treatment.
  • Setting up therapy parameters: Adjust intensity, frequency, and duration.

Unit Settings

The machine offers various settings for customization:

  1. Mode 1 Operation: The operation interface of mode 1 allows you to set the handle operation time according to customer needs. Take out the handle from the handle frame before operation, and use the belt to fix the handle to the operating part required by the customer. The frequency of mode one is 5-60Hz. Adjust the corresponding intensity according to customer needs and click start/stop.
  2. Mode 2 Operation: The operation interface of mode 2 allows for setting three different periods of frequency, which can be freely adjusted. The frequency of mode two is 30-100Hz. Adjust the corresponding intensity/stage frequency/time according to customer needs, click the start/pause button to enter the operation work.
  3. Language Settings: Select your preferred language from the available options.
  4. Sound Adjustment: Control the device's sound volume.
  5. Brightness Adjustment: Adjust the screen brightness for optimal visibility.
  6. Set Date/Time: Configure the current date and time.
  7. System Adjustment: Access system-level settings (may require a password).
  8. Technician Access: For authorized technicians to perform advanced diagnostics and maintenance (requires password).

Note: If the customer requests to pause, they can click the start/pause button to pause the work, and after the work is completed, they can directly click the return key to return.

Video demonstrating the power-on sequence, navigation through the touch screen interface, adjustment of treatment parameters, and application of the handle to a user's arm.

5. Maintenance

Daily Inspection

Regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.

Cleaning

  • Device Surface: Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off. The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean, do not use alcohol-based detergents.
  • Accessories in Contact with Patient: The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole, wipe with pure cotton material.

Fuse Replacement

When replacing the fuse, in order to prevent electric shock, please turn off the power and unplug the power plug. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.

Storage and Transportation

  • Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The ambient temperature should be -10°C ~ 40°C, relative humidity not greater than 93%, and it is not allowed to be placed in harmful gases, around flammable, explosive substances and corrosive gases.
  • Transportation: The instrument under the packaging condition is suitable for road, railway, air and water transportation. During loading, unloading and transportation, it should prevent severe vibration and shock, and should not be affected by moisture, and should not be mixed with flammable and corrosive substances. Specific requirements are specified in the order contract.

6. Troubleshooting

Common Faults and Troubleshooting Methods

Fault PhenomenonCausesExclusions and Workarounds
Device not workingThe power plug is not inserted into the socket
Power switch not on
Power fuse failure
Check the power
Check the power switch
Replace the fuse
Handle not workingCheck the handle for loose connectionReseat the handle

7. Specifications

Product Properties

AttributeValue
Brand NameMYOSLIM
Item TypeEpilator (Photoepilators)
UseBODY
Power TypeFrom mains or battery
Power SourceFrom mains or battery
Voltage220V (available in 110V options)
OriginMainland China
CertificationCE, RoHS
High-concerned chemicalNone
Frequency100-200hz
Muscle contraction>30,000 times
Gross weight68kg
Screen10.4 inch Color Touch Screen
Operation ModeManual Mode + Automatic Mode
Power6500W
Pulse width300us
Feature 1body slimming machine
TechnologyHigh-Intensity Electromagnetic
Standard handles2 big handles + 2 small handles

Radiated Electromagnetic Field Immunity Test

PortEnclosure
Basic StandardIEC 61000-4-3:2020
Test Level30V/m with 80% AM. 1kHz Modulation.
Standard requireA
TesterSam Liu
Temperature25°C
Humidity54%

Test Equipment

DescriptionManufacturerModelIdentifierCal. DateCal. Due
Signal GeneratorIFA2023BN/A15/03/202214/03/2023
Power AmplifierAR150W1000N/A15/03/202214/03/2023
Power AntennaAR25S1G4AN/A15/03/202214/03/2023

Block Diagram of Test Setup

Block diagram of the electromagnetic compatibility test setup for the EMS Body Sculpt machine, showing a 7x4x3 chamber, EUT & Support, Power Amp, Signal Generator, PC Controller, and Control Room with EUT Monitoring via camera.
Block diagram illustrating the setup for electromagnetic compatibility testing, including the chamber dimensions, equipment under test (EUT), and control components.

8. Warranty and Support

Warranty Information

  1. The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance.
  2. The main machine is guaranteed for one year (excluding fragile parts and other non-warranty scope or expired warranty period). Maintenance and updates are available, with appropriate charges for maintenance fees.
  3. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping cost. After six months, the buyer shall bear all shipping costs.
  4. Free warranty service is not provided for user failures caused by personal reasons, including:
    • Faults caused by unauthorized disassembly and modification of this product;
    • Faults caused by accidental fall;
    • Failure caused by lack of reasonable maintenance;
    • Failure to operate according to the correct instructions in this instruction manual.

Term of Use

The continued use of the instrument beyond the service period shall be subject to the approval of the engineer, and the engineer shall conduct a performance test of the instrument periodically in the subsequent use. Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.

Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

For a detailed user manual in PDF format, please refer to the User Manual (PDF).

9. User Tips

  • Always ensure the handles are securely attached before starting any treatment to prevent interruptions or improper application.
  • Start with lower intensity settings and gradually increase as comfort allows, especially when using the machine for the first time or on a new body area.
  • Keep the touch screen clean with a soft, dry cloth to maintain responsiveness and visibility.
  • Regularly check the power cord for any signs of damage to ensure safe operation.