MYOSLIM M22

Contents

MYOSLIM M22 Multifunctional Laser Beauty Machine User Manual

Model: M22

Thank you for choosing the MYOSLIM M22 Multifunctional Laser Beauty Machine. This manual provides essential information for safe and effective operation.

1. Introduction to the M22 System

The MYOSLIM M22 is an advanced aesthetic device combining multiple technologies for comprehensive skin treatment. It integrates OPT (Optimal Pulse Technology), ND YAG Laser, and E-Light functionalities to address a wide range of skin concerns including hair removal, skin rejuvenation, acne treatment, dark spot and wrinkle removal, tattoo removal, and anti-aging.

2 in 1 Multifunctional M22 OPT + ND YAG Laser Beauty Machine with icons for various treatments.
Figure 1: Multifunctional M22 System Overview

Key Advantages:

  • Non-invasive and non-ablative treatment for skin.
  • Superior performance and patient comfort with no downtime.
  • Significantly less energy required than conventional lasers and IPLs.
  • Quick and easy handpiece installation.
  • Pain-free skin contact technology.
  • Upper and lower double switch, adapting to different operator habits.
  • State-of-the-art design.
  • Modularized assembly technique for easy maintenance.
Advantages of the M22 machine, including non-invasive treatment, superior performance, quick handpiece installation, pain-free technology, double switch, state-of-the-art design, and modularized assembly.
Figure 2: M22 System Advantages

2. Safety Information

Always read and understand all instructions before using the M22 machine. Failure to follow safety guidelines may result in injury or damage to the device.

2.1 General Safety Precautions

  • Ensure the machine is placed on a stable, level surface.
  • Keep the treatment area clean and free of obstructions.
  • Only trained and certified professionals should operate this equipment.
  • Wear appropriate protective eyewear during all laser and IPL treatments.
  • Ensure the patient also wears protective eyewear.
  • Do not operate the machine if any part is damaged or malfunctioning.
  • Keep out of reach of unauthorized personnel.

2.2 Electrical Safety

  • Connect the machine to a grounded power outlet with the correct voltage (110V or 220V depending on model).
  • Do not use extension cords or adapters unless absolutely necessary and rated for the machine's power requirements.
  • Unplug the machine before cleaning or maintenance.

3. Setup and Assembly

Follow these steps to set up your M22 machine:

  1. Unpacking: Carefully remove all components from the packaging. Inspect for any signs of damage.
  2. Placement: Position the main unit on a sturdy, flat surface in a well-ventilated area. Ensure adequate space around the machine for air circulation, especially at the rear where exhaust fans are located.
  3. Power Connection: Connect the power cord to the machine and then to a suitable grounded electrical outlet.
  4. Handpiece Connection: Connect the IPL and ND YAG handpieces to their respective ports on the front of the machine. Ensure connections are secure.
Main view of the M22 machine with two handpieces connected.
Figure 3: M22 Machine with Handpieces Connected
Rear view of the M22 machine showing connections and warning labels.
Figure 4: Rear Panel Connections
  1. Filter/Tip Installation: For IPL treatments, select the appropriate filter (e.g., 420nm for acne, 690nm for dark hair removal) and insert it into the IPL handpiece. For ND YAG laser treatments, attach the correct tip (e.g., 532nm, 1064nm, 1320nm) to the laser handpiece.
M22 with a case of various IPL filters (420-1200nm, 530-1200nm, 560-1200nm, 640-1200nm, 690-1200nm).
Figure 5: IPL Filters for Different Wavelengths
Close-up of IPL handle with filters and Laser handle with different tips (532nm, 1064/532nm, 1064nm, 1320nm).
Figure 6: IPL Filters and Laser Tips

For a visual guide on handpiece and filter installation, please refer to the product demonstration video:

Video 1: M22 Product Demonstration (shows filter installation and general operation)

For detailed instructions, please consult the User Manual (PDF).

4. Operating Instructions

4.1 General Operation

  1. Power On: Press the main power switch on the machine. The display screen will light up.
  2. Select Treatment Mode: Navigate the touchscreen interface to select the desired treatment mode (e.g., IPL, ND YAG, MMFU).
  3. Parameter Adjustment: Adjust the energy, pulse width, frequency, and other parameters according to the specific treatment protocol and patient's skin type.
  4. Apply Gel: Apply a thin layer of coupling gel to the treatment area.
  5. Perform Treatment: Place the handpiece firmly on the skin and activate the laser/IPL/ultrasound pulses as per the selected mode.
  6. Power Off: After treatment, turn off the machine using the main power switch.

4.2 MMFU (Macro & Micro Focused Ultrasound) Treatment

The MMFU technology uses high-energy focused ultrasound to target specific skin layers, promoting collagen regeneration and fat cell destruction. It features both micro-focused ultrasound for facial applications and macro-focused ultrasound for body applications.

Diagram illustrating Picosecond Laser Treatment Theory, showing ultra-short pulses shattering melanin.
Figure 7: Picosecond Laser Treatment Theory
MMFU Working Principle diagram showing transducer, aperture diaphragm, geometric focal length, and high energy focusing region.
Figure 8: MMFU Working Principle
Diagram comparing MMFU facial application (micro-focused ultrasound) with body application (macro-focused ultrasound), showing different penetration depths and cartridge sizes.
Figure 9: MMFU Facial vs. Body Application

4.2.1 Facial Treatment Areas & Probes

The M22 offers specialized probes for facial treatments:

  • 1.5 mm Probe (Toning): Targets the epidermis to improve superficial fine lines, skin tone, skin texture, and fine pores.
  • 2.0 mm Probe (Wrinkle Erasing): World's original probe specializing in eyes and deep lines such as forehead, neck, and crow's feet. (Unique ultra-thin probe with Clexis patented technology, 5.5Mhz 2.0mm)
  • 3.0 mm Probe (Tightening): Aims at the dermis to stimulate continuous regeneration of collagen.
  • 4.5 mm Probe (Lifting): Acts on the SAMA fascia layer to tighten the muscle bottom and achieve firmness.
Quartet facial treatment Probe with powerful effect, showing 1.5mm, 2.0mm, 3.0mm, and 4.5mm probes and their functions.
Figure 10: Facial Treatment Probes
Diagram showing MMFU Mechanical effect + heat effect + Cavitation effect on collagen regeneration.
Figure 11: MMFU Effects on Collagen
Facial effects showing before and after images for age reduction.
Figure 12: Facial Treatment Results
MF2 5.5MHz Patented technology for 2.0mm eye probe.
Figure 13: MF2 5.5MHz Eye Probe Technology
MF2 Global original probe for eye treatment, showing before and after images.
Figure 14: MF2 Eye Probe Application

4.2.2 Body Treatment Areas & Probes

MMFU macro-focused ultrasound targets fat cells, destroying them at approximately 50°C without harming surrounding tissues. This helps in body contouring and fat dissolving.

Diagram showing MMFU Mechanical effect + heat effect + Cavitation effect for fat cell destruction.
Figure 15: MMFU Effects on Fat Cells

Exclusive 6.0mm and 9.0mm probes are designed for body treatments, offering wider application range and effective local precision sculpture. A 6.0mm probe is particularly effective for improving double chin.

Body effect diagram showing before and after results for fat reduction and contouring.
Figure 16: Body Treatment Effects

Common body treatment sites include:

Body treatment site diagram highlighting Chest, Armpit, Arm, Abdomen, Thigh, Calf, Ankle, Back, and Both sides of waist.
Figure 17: Body Treatment Areas

Facial treatment areas include:

Facial treatment area diagram highlighting Forehead Wrinkle, Eyebrow, Cheek, Jowl Line, Wrinkle Lifting, Skin Tone Improvement, V-line Forming, Double Chin, and Neck Wrinkle.
Figure 18: Facial Treatment Areas

4.2.3 Treatment Parameters and Cautions

Always ensure the patient wears protective eyewear during facial treatments. For multi-level nursing, treatments should progress from shallow to deep. If repeating treatments, use horizontal and vertical composite methods as instructed.

Forehead and Around the Eye Sockets
Diagram showing treatment pattern for forehead and eye sockets.
Figure 19: Forehead and Eye Sockets Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
1.5mm0.1-0.2J1.0-1.5mm1120

Cautions:

  • Do not directly treat the orbital or cervical nerve area.
  • Adjust the dot pitch between 10mm and 15mm before treatment.
  • Ask the patient to close their eyes.
  • When treating the periorbital area and eyebrow line, pull the tip of the probe firmly to the forehead to relieve pain.
Upper Arm
Diagram showing treatment pattern for upper arm.
Figure 20: Upper Arm Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
6.0mm0.8-1.5J1.0-1.5mm275/75
4.5mm0.6-1.0J1.0-1.5mm275/75
3.0mm0.6-0.9J1.0-1.5mm275/75

Cautions:

  • Do not directly treat the nerve area.
  • In multi-level nursing, treatment should be carried out from shallow to deep (e.g., 4.5mm-3.0mm-1.5mm).
  • For treatments repeated twice, use the horizontal and vertical composite method.
Knee
Diagram showing treatment pattern for knee.
Figure 21: Knee Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
6.0mm1.0-2.0J1.0-1.5mm230/30
4.5mm0.6-0.9J1.0-1.5mm230/30
3.0mm0.6-0.8J1.0-1.5mm230/30

Cautions:

  • Do not directly treat the nerve area.
  • In multi-level nursing, treatment should be carried out from shallow to deep (e.g., 4.5mm-3.0mm-1.5mm).
  • For treatments repeated twice, use the horizontal and vertical composite method.
Fine Lines and Deep Wrinkles (Facial)
Diagram showing treatment pattern for fine lines and deep wrinkles on the face.
Figure 22: Fine Lines and Deep Wrinkles Treatment Pattern
AreaProbeEnergyDot PitchRepeatNumber of Shots
Forehead2.0mm0.1-0.2J1.4-1.5mm190
Around the eyes2.0mm0.1-0.2J1.4-1.5mm1100
Around the mouth2.0mm0.1-0.2J1.4-1.5mm180

Cautions:

  • Do not directly treat the supraorbital or cervical nerve area.
  • Adjust the point spacing between 10mm and 15mm before treatment.
  • Patient should close their eyes when treating the orbital area.
  • Pull the tip of the probe firmly to the forehead and output energy to relieve pain.
  • For treatments repeated once, apply the processing mode as instructed.
Jaw and Neck
Diagram showing treatment pattern for jaw and neck.
Figure 23: Jaw and Neck Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
4.5mm0.5-0.8J1.0-1.5mm1135
3.0mm0.3-0.5J1.0-1.5mm1135
1.5mm0.1-0.2J1.0-1.5mm165

Cautions:

  • Do not directly treat the marginal mandibular nerve area.
  • Do not apply too much pressure on the neck to prevent impermeability during treatment.
  • In multi-level nursing, treatment should be carried out from deep to shallow.
  • For treatments repeated once, apply the processing mode as instructed.
Chest and Shoulder
Diagram showing treatment pattern for chest and shoulder.
Figure 24: Chest and Shoulder Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
4.5mm0.2-0.4J1.0-1.5mm1120
3.0mm0.2-0.4J1.0-1.5mm1120
1.5mm0.1-0.2J1.0-1.5mm140

Cautions:

  • Do not directly treat the clavicle, breast tissue, or breast implant area.
  • In multi-level nursing, treatment should be carried out from deep to superficial (e.g., 4.5mm-3.0mm-1.5mm).
  • For treatments repeated once, apply the processing mode as instructed.
Waist
Diagram showing treatment pattern for waist.
Figure 25: Waist Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
13.0mm0.8-1.3J1.0-1.5mm3300/300
9.0mm0.8-1.5J1.0-1.5mm3300/300
6.0mm0.6-1.2J1.0-1.5mm3300/300

Cautions:

  • Do not directly treat the PSIS (Posterior Superior Iliac Spine) or the pelvic area.
  • In multi-level nursing, treatment should be carried out from deep to superficial.
  • For treatments repeated 3 times, use the horizontal and vertical compound method.
Armpit
Diagram showing treatment pattern for armpit.
Figure 26: Armpit Treatment Pattern
ProbeEnergyDot PitchRepeatNumber of Shots
6.0mm0.6-0.9J1.0-1.5mm220/20
4.5mm0.5-0.8J1.0-1.5mm220/20
3.0mm0.5-0.8J1.0-1.5mm220/20

Cautions:

  • Do not directly treat breast tissue or the ulnar nerve.
  • In multi-level nursing, treatment should be carried out from deep to superficial.
  • For treatments repeated twice, use the horizontal and vertical composite method.

5. Maintenance and Care

Proper maintenance ensures the longevity and optimal performance of your M22 machine.

  • Cleaning: Regularly clean the exterior of the machine and handpieces with a soft, damp cloth. Avoid abrasive cleaners or solvents.
  • Filter/Tip Cleaning: Clean IPL filters and laser tips after each use according to manufacturer guidelines to ensure optimal light/laser transmission.
  • Cooling System: The machine features double exhaust fans for efficient cooling. Ensure these vents are not blocked to prevent overheating.
Product details showing imported handle, double exhaust fan, and imported machine components.
Figure 27: Internal Components (Double Exhaust Fan)
  • Modular Design: The modularized assembly technique allows for easier maintenance and component replacement if needed.
  • Storage: When not in use, store the machine and handpieces in a clean, dry, and dust-free environment.

6. Troubleshooting

If you encounter any issues with your M22 machine, please refer to the following general guidelines:

  • Machine Not Powering On: Check the power cord connection and ensure the power outlet is functional. Verify the main power switch is in the 'On' position.
  • Handpiece Not Functioning: Ensure the handpiece is securely connected to the machine. Check for any error messages on the display screen.
  • Unusual Noises or Odors: Immediately power off the machine and unplug it. Contact customer support for assistance.
  • Reduced Performance: Ensure filters and tips are clean and correctly installed. Verify that treatment parameters are set appropriately for the desired outcome.

For complex issues or repairs, please contact MYOSLIM customer support. Do not attempt to repair the machine yourself, as this may void your warranty and cause further damage.

7. Specifications

FeatureSpecification
Brand NameMYOSLIM
ModelM22
Item TypeEpilator (Multifunctional Laser Beauty Machine)
Efficacy PrincipleLaser/IPL/Radio Frequency
Voltage110V (or 220V, depending on SKU)
Power TypeElectric
Power SourceElectric
MaterialABS
FunctionalityHair removal, Skin rejuvenation, Acne treatment, Dark spots & wrinkles removal, Inflammation reduction, Red blood streak removal, Tattoo removal, Anti-aging
Number of Lamp Heads5 or more pieces
Epilator TypeLaser
CertificationRoHs, CE
Package Length80 cm
Package Width63 cm
Package Height63 cm
Package Weight68.0 kg

8. User Tips

  • Pre-Treatment Consultation: Always conduct a thorough consultation with clients to assess skin type, concerns, and medical history to determine appropriate treatment parameters and ensure safety.
  • Skin Preparation: Ensure the treatment area is clean, dry, and free of makeup, lotions, or deodorants before applying coupling gel.
  • Consistent Gel Application: Use a generous and even layer of coupling gel to ensure optimal contact between the handpiece and skin, which is crucial for effective energy delivery and patient comfort.
  • Gradual Parameter Adjustment: Start with lower energy settings and gradually increase them based on client comfort and skin reaction.
  • Post-Treatment Care: Advise clients on proper post-treatment care, including sun protection, moisturizing, and avoiding harsh skincare products.

9. Frequently Asked Questions (FAQ)

Q: What is the difference between IPL and Laser treatments?
A: IPL (Intense Pulsed Light) uses a broad spectrum of light, while laser uses a single, focused wavelength. Both are effective for various skin concerns, but lasers are generally more precise for specific targets like tattoo removal, while IPL is versatile for hair removal, pigmentation, and skin rejuvenation.
Q: Is the treatment painful?
A: The M22 machine incorporates pain-free skin contact technology. Most clients report minimal discomfort, often described as a warm sensation or a light snap. Topical anesthetics can be used if necessary.
Q: How many sessions are required for optimal results?
A: The number of sessions varies depending on the treatment area, skin condition, and individual response. Typically, a series of sessions is recommended for best results, with follow-up treatments as needed.
Q: Can this machine be used on all skin types?
A: While advanced machines like the M22 are designed for versatility, certain skin types (especially darker skin tones) may require specific settings or different treatment modalities to minimize risks. Always follow professional guidelines and conduct a patch test.

10. Warranty and Support

The MYOSLIM M22 machine comes with an after-sales service guarantee. We are committed to providing reliable support for your product.

Certificates and awards for the product/brand.
Figure 28: Product Certifications

For any questions, technical assistance, or warranty claims, please contact MYOSLIM customer support through your purchase platform or the official MYOSLIM channels. Please have your product model and purchase date available when contacting support.

Your encouragement is our greatest motivation for progress.

© 2024 MYOSLIM. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.