Thank you for choosing the Portable RF Body Slimming Machine. This manual provides essential information for the correct and safe operation of your device. Please read it thoroughly before use to ensure proper function, prevent damage, and achieve optimal results.
This instrument utilizes advanced radiofrequency (RF) technology for non-invasive fat removal and skin tightening. It works by delivering RF energy to different treatment depths, generating heat that induces apoptosis of adipocytes (fat cells) and stimulates collagen and elastin proliferation. This process helps to eliminate localized fat, improve skin laxity and texture, tighten facial contours, and reduce fine lines.
The treatment is designed to be safe, reliable, and comfortable, with no recovery period or rebound effect, allowing for simultaneous skin tightening and body shaping.
1.1 Key Advantages
- Non-Invasive & Safe: No needles, incisions, or downtime.
- Dual Handles: Dedicated handles for targeted body and facial treatments.
- Accurate & Effective: Precise control over treatment depth and energy.
- Comfortable & Painless: Designed for a comfortable user experience.
- Significant Results: Visible improvements in fat reduction, skin elasticity, and wrinkle reduction.
1.2 Treatment Areas & Benefits
The device is effective for various areas:
- Face: Reduces wrinkles on the forehead, around eye orbits (improving eye bags), lifts cheeks to eliminate nasolabial folds, tightens the lower jaw to eliminate double chin, and firms neck skin.
- Body: Reduces excess fat and cellulite in arms, abdomen, thighs, and buttocks, leading to a more contoured silhouette.





2. Product Overview
The Portable RF Body Slimming Machine is a compact and versatile device designed for professional and personal use. It features a main unit with a display screen and controls, along with two specialized handles for different treatment areas.
2.1 Instrument Appearance





2.2 Product Parameters

The main components include:
- Body Handle: Large probe for body treatments.
- Face Handle: Small probe for facial treatments.
- Display Screen: Touch interface for settings and monitoring.
- Control Buttons: Enter, Return, Energy Regulation knob, Power button, Start/Stop.
- Power Switch: Main power control.
- Power Socket: For connecting the power cord.
- Heat Dissipation Hole: Ensures proper cooling during operation.
- Watering Hole: For adding water (if applicable, refer to specific model instructions).
- Dewatering Hole: For draining water (if applicable).
3. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Type | Portable |
| Hand Instrument | Yes |
| Power Supply | Battery Powered |
| Electronic | No |
| Voltage | 50-1000V AC |
| Material | ABS+Steel |
| Technology | Vacuum+Cavitation+ RF |
| Application | For Commercial, Beauty Center & Click |
| Package Length | 40 cm |
| Package Width | 39 cm |
| Package Height | 46 cm |
| Package Weight | 15.0 kg |
4. Safety Information
Please read and adhere to all safety instructions to prevent injury or damage to the device.
4.1 Handling Safety
- This is a precision instrument. Avoid moving it long distances. If transportation is necessary, use the original shock-absorbing packaging to prevent damage to the optical system and energy output.
- Do not disassemble the instrument or attempt repairs not described in this manual. All maintenance must be performed by qualified personnel approved by the company.
- Do not install or operate the instrument near water sources or with wet hands. Avoid spilling liquids on the instrument.
- Do not place items on the power cord or install the instrument where the power cord can be easily stepped on.
- Always unplug the power cord after use to ensure safety.
- Do not insert any items into the openings of the instrument to prevent fire or electric shock.
4.2 Electrical Safety
- The operating system uses a single-phase 220V power supply with a maximum output current of 10A or less.
- To prolong service life and reduce the impact of power grid fluctuations, it is recommended to use a 3000W voltage regulator.
- Ensure the power supply matches the machine's specifications to prevent malfunction or damage.
- The device must be properly grounded through the three-core power supply for safe operation.
4.3 Operation Safety
- This instrument is intended for beauty salons and commercial use, not for home users. Operation by non-professionals may cause injury.
- Upon receiving the instrument, check all accessories and inspect for damage. Report any transportation damage to the manufacturer immediately.
4.4 Contraindications (Taboo)
- Do not use on areas with large ulcers, pustule-type acne, bedsores, or skin diseases.
- Do not use if suffering from inflammation, hypertension, heart disease, or diabetes.
- For women, facial treatments are generally not affected during menstrual periods, but body treatments should be avoided during pregnancy, lactation, and menstrual periods.
5. Setup
Before operating the device, ensure all components are correctly connected and the machine is ready for use.
5.1 Initial Preparation
- Unpacking: Carefully remove the machine and all accessories from the packaging. Retain the original packaging for future storage or transport.
- Placement: Place the main unit on a stable, flat surface, ensuring adequate ventilation around the heat dissipation holes.
- Handle Connection: Connect the body handle and face handle to their respective jacks on the main unit. Ensure they are securely fastened.
- Power Connection: Connect the power cord to the power socket on the back of the machine, then plug it into a grounded electrical outlet.
- Water Filling (if applicable): If your model requires water, fill it through the watering hole as per specific instructions.
5.2 Pre-Operation Checklist
- Verify all accessories are present and undamaged.
- Ensure the power cord is intact and not chafed.
- Confirm the handles are correctly and securely installed.
- Check that the main power switch is in the OFF position before plugging in.
6. Operation Instructions
Follow these steps to operate the Portable RF Body Slimming Machine.
6.1 Power On
- After connecting all components, turn on the main power switch located at the back of the machine.
- The LCD screen on the panel will light up, indicating the machine is in working state.
6.2 Interface Description and Settings

- Select Handle: On the main screen, click the icon in the lower left corner to select the body handle (large probe) operation, or click the icon to select the face handle (small probe) operation.
- Enter Operation Interface: After selecting the desired handle, press the 'Enter' key to access the specific operation interface for that handle.
- Adjust Energy: Use the instrument's knob or on-screen controls to adjust the energy level. It is recommended to start testing around 80 and adjust based on the customer's comfort. If the energy is set to 90 and no heat is felt, adjust the output energy percentage to 80% or 100%.
- Cooling Temperature: Adjust the cooling temperature. The maximum cooling can be set to 30 degrees. If the energy is high (e.g., 120) and the customer still doesn't feel hot, 30 degrees of refrigeration can be chosen.
- Set Time: Adjust the treatment time as required.
- Start Operation: After setting all parameters, tap 'Start' to begin the treatment.
- Pause/Stop: During operation, you can press 'Pause' to temporarily stop or 'Stop' to end the session.
- Return to Home: After completing a treatment, press the handle screen to return to the previous screen, then tap 'Esc' to return to the home screen to select another treatment area or handle.
6.3 Treatment Process
- Preparation Stage:
- Choose Care Project: Select the appropriate treatment area and method based on the customer's needs.
- Customer File Registration: Record customer information, take before photos, and confirm treatment items.
- Treatment Site Planning: Develop a focused treatment plan for the specific skin concerns.
- Introduce Plan: Explain the nursing plan, potential reactions, and post-treatment care to the customer.
- Tool Preparation: Gather all necessary items for the operation.
- Clean Treatment Site: Thoroughly clean and dry the skin. Disinfect the beautician's hands and the instrument's head. Remove all metal products (rings, watches, necklaces) from the customer.
- Operation: Apply a suitable conductive gel to the treatment area. Perform the treatment according to the selected parameters and technique.
7. Maintenance
Proper maintenance ensures the longevity and optimal performance of your device.
- Cleaning: Regularly clean the device's exterior and handles with a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Handle Care: Ensure the handles are clean and free from gel residue after each use. Store them properly in their designated holders.
- Storage: When not in use, store the machine in a cool, dry place, away from direct sunlight and moisture. If storing for an extended period, use the original packaging.
- Water System (if applicable): If your model uses a water cooling system, regularly check and replenish the water level. Follow instructions for draining and refilling to prevent algae buildup or system blockages.
8. Troubleshooting
Refer to the table below for common issues and their solutions.
| Fault Phenomenon | Cause | Exclusions and Solutions |
|---|---|---|
| Equipment not working |
|
|
| Handle not working |
|
|
If the problem persists after attempting these solutions, please contact customer support.
9. User Tips
- Consistent Use: For best results, adhere to a consistent treatment schedule as recommended by a professional or the device guidelines.
- Hydration: Maintain good hydration before and after treatments to support skin health and fat metabolism.
- Diet & Exercise: Complement treatments with a balanced diet and regular exercise for enhanced and lasting results.
- Skin Sensitivity: Always perform a patch test on a small area of skin before full treatment to check for any adverse reactions.
- Professional Guidance: If you are new to RF treatments, consider consulting with a professional beautician for personalized advice and initial sessions.
10. Warranty & Support
The manufacturer provides a warranty for this product under specific conditions. Please refer to the warranty card included with your purchase for full details.
10.1 Warranty Exclusions
Free warranty service will not be provided for failures caused by:
- Unauthorized disassembly or modification of the product.
- Inadvertent falls or impacts.
- Lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this manual.
10.2 After-sales Service
Our service includes 24-hour online support, video technical support, and online training for operation. We also provide free spare parts when necessary.