1. Introduction
The MYAMI ES Series Hybrid Solar Inverter is designed for photovoltaic solar power generation systems, converting direct current (DC) into alternating current (AC). This integrated inverter controller offers a compact and efficient solution for off-grid power generation.
Key advantages of the MYAMI ES Series include reduced transportation costs for solar controllers, minimized external installation space, and simplified wiring. These inverters feature a dual LCD display for intuitive monitoring of operational data for both the solar controller and inverter functions.
Available in 3KW, 5KW, and 6KW power options (MY-ES3000B, MY-ES5000B, MY-ES6000B), each model is equipped with a built-in 60A MPPT solar controller for efficient energy tracking and conversion. They support a wide range of battery types, including lead-acid, GEL, AGM, and lithium iron phosphate, with support for up to 96V battery systems. Users can also customize battery settings and charging currents to suit specific application needs.
These hybrid inverters are ideal for off-grid power generation systems, enabling autonomous electricity generation and usage, thereby reducing reliance on the main power grid and offering flexibility in various applications.
2. Safety Instructions
This chapter contains important safety and operational instructions. Please read all instructions and warning marks in this manual before installation and operation. Keep this manual for future reference.
- Only qualified personnel should install and operate this equipment with batteries.
- Never change the factory settings unless you are an expert. Incorrect settings may cause battery damage or fire.
- Ensure the inverter is properly grounded.
- Do not install the inverter on flammable building materials.
- Mount the inverter on a solid surface.
- Install the inverter at eye level for easy reading of the LCD display.
- Allow sufficient air circulation for heat dissipation: reserve at least 25 cm clearance on the back and 30 cm on each side of the equipment.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- It is recommended to install the unit vertically on a wall.
- Ensure other objects and surfaces are positioned as shown in diagrams to allow for sufficient heat dissipation and space for wiring.
- The maximum voltage input of the solar panel is 220V (for 5000W/6000W models) or 230V (for 3000W model).
- The input voltage and battery voltage must be consistent with the inverter's specifications.
- When performing maintenance or cleaning, always disconnect the battery by pulling out the battery cable first.
3. Setup
3.1. Installation of the Equipment
Before selecting the installation location, consider the following points:
- Do not install the inverter on flammable building materials.
- Mount it on a solid surface.
- Install the inverter at a height that allows easy reading of the LCD display.
- For proper heat dissipation, ensure a minimum clearance of 25 cm on the back and 30 cm on each side of the equipment.
- The optimal operating ambient temperature is between 0°C and 55°C.
- Vertical wall mounting is recommended.
- Ensure adequate space around the unit for heat dissipation and wiring access.
3.2. Line Connection Method
Follow the correct wiring sequence for the energy controller:
- First, connect the positive and negative electrodes of the battery.
- Next, connect the positive and negative poles of the DC load.
- Finally, connect the positive and negative electrodes of the solar panel.
Note: The input voltage and battery voltage must be consistent with the inverter's specifications. The maximum input voltage for the solar panel is 230V.
4. Operating Instructions
4.1. Appearance and Display Description
The inverter features a dual LCD display for comprehensive monitoring and control. The main display shows real-time operational data, while the secondary display provides additional details.
4.2. Push-Button Operating Instructions
The inverter is controlled via four buttons located below the LCD display:
- Set up / Back: Used to enter the main menu or go back to the previous screen.
- Flip up button: Used to navigate upwards through menu options or increase values.
- Flip down button: Used to navigate downwards through menu options or decrease values.
- OK button: Used to confirm selections or enter submenus.
4.3. Parameter Setting Operation Procedure
From the default main interface, press the SET key to enter the main menu. Use the DOWN or UP keys to view submenus. Press the OK key to enter a submenu.
Battery Type Setting:
- There are 4 built-in battery types to choose from. Users can also add custom battery types.
- After selecting the battery type, click Enter to set the required voltage.
Charging Current Setting:
- The charging current setting range varies with different products. Refer to the "Parameter Table" for details.
DC Output Setting:
- Click to select to turn on or off the DC load.
Language Setting:
- Available in Chinese and English.
Restore Factory Settings:
- If you need to clear all records, you can restore them to factory settings.
5. Maintenance
Regular maintenance ensures the longevity and optimal performance of your MYAMI Hybrid Solar Inverter.
- Cleaning: Keep the inverter clean and free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Ventilation: Ensure that the ventilation openings are not blocked to allow proper airflow for cooling.
- Connections: Periodically check all electrical connections (battery, solar panel, AC input/output) to ensure they are secure and free from corrosion.
- Battery Disconnection: When performing any service, maintenance, or cleaning, always disconnect the battery by pulling out the battery cable first to prevent electrical hazards.
- Environmental Conditions: Ensure the inverter operates within the specified ambient temperature range (0°C to 55°C) and avoid exposure to excessive moisture or direct sunlight.
6. Troubleshooting
The inverter is equipped with multiple protection features and displays error codes on the LCD screen to indicate specific issues. Refer to the table below for common error codes and their descriptions:
| Error Code | Description |
|---|---|
| E01 | Short circuit function prompt |
| E02 | Input undervoltage prompt |
| E03 | Over temperature protection prompt |
| E04 | Overload protection prompt |
| E05 | Input overvoltage prompt |
| E06 | Pre-stage power overload prompt |
If you encounter any of these error codes, first check the corresponding system component (e.g., wiring for short circuit, battery voltage for undervoltage, load for overload). If the issue persists after basic checks, contact customer support.
7. Specifications
The MYAMI ES Series Hybrid Solar Inverter comes in various power options with specific dimensions and electrical characteristics.
| Attribute | MY-ES3000B | MY-ES5000B | MY-ES6000B |
|---|---|---|---|
| Product Name | Hybrid Solar Inverter | ||
| Output Type | SINGLE | ||
| Is Smart Device | Yes | ||
| EU LVD Voltage | High voltage: Above 50Vac or 75Vdc | ||
| Rated Power | 3000W | 5000W | 6000W |
| MPPT Charging Current | 60A | ||
| Battery Input Voltage | 12V/24V/48V/60V/72V/96V | 24V/48V/60V/72V/96V | DC 24V/48V/60V/72V |
| Size (L*W*H) | 39.3*33*10.5cm | 39.3*39*10.5cm | 39.3*39*10.5cm |
| Weight | 7.3kg | 9.18kg | 9.18kg |
| MPPT Efficiency | 97%-99% | ||
| Protection | Short circuit, overload, overvoltage, overtemperature | ||
| Display screen | Dual LCD Displays | ||
| Cooling | Smart fan cooling | ||
Package Dimensions:
- Length: 53 cm
- Width: 53 cm
- Height: 23 cm
- Weight: 12.0 kg
8. Warranty and Support
The MYAMI ES Series Hybrid Solar Inverter comes with a one-year free warranty. During this period, if any damage or failure occurs, the machine will be provided with free maintenance and replacement of parts. The warranty may be voided if damage is caused by faulty operation, negligence, unauthorized modification, or failure to install according to the provided instructions.
For technical support, warranty claims, or any inquiries, please contact MYAMi Official Store directly. You can also refer to the User Manual (PDF) for additional details.
9. User Tips
9.1. Determining Battery Needs for a 3000W Inverter
To size your battery bank for a 3000W inverter, consider your daily electricity consumption and desired backup duration. A simplified calculation involves:
- Calculate Daily Power Consumption (Wh): Sum the power consumption of all devices (Rated Power x Hours of Use). For example, 3000W used for 1 hour = 3000Wh/day.
- Determine Backup Days: Multiply daily consumption by the number of backup days needed.
- Account for Depth of Discharge (DOD): Divide the result from step 2 by your maximum desired DOD (e.g., if DOD is 50%, divide by 0.5).
- Consider Temperature Efficiency: Batteries are less efficient at lower temperatures; factor this into your calculation.
- Calculate Battery Pack Capacity (Ah): Connect batteries to achieve your system voltage (12V, 24V, 48V, etc.). Divide the result from step 4 by the required battery voltage.
- Determine Number of Batteries: If you need a 1050Ah battery pack using 12V 105Ah batteries, you would need 10 batteries (1050Ah / 105Ah = 10).
For complex calculations or personalized recommendations, contact MYAMI directly for customized assistance. The Solar Inverter supports 12V, 24V, 48V, 60V, 72V, and 96V battery systems.
9.2. What a 3000 Watt Solar Inverter Can Run
A 3000-watt inverter can power various devices as long as their combined power demand does not exceed 3000 watts. Always check the rated power of your appliances, usually found on their labels.
Typically, large inverters can handle a 15-20% overload for short periods. Therefore, a 3000W inverter is generally suitable for operating loads totaling approximately 2400-2500 watts continuously.
Common appliances a 3000W inverter can comfortably power include:
- Lighting loads
- Refrigerators
- Microwaves
- Coffee machines
- Charging mobile phones and laptops
Always verify the specific power ratings of your equipment, as they can vary.