When operating this product, please read the instrument manual carefully first.

1. General Information

The MYOslim Hi-EMT Body Sculpt Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions. This process promotes muscle growth and reshapes the internal structure of muscles. Additionally, it triggers significant fat breakdown through intense muscle contractions, releasing fatty acids from triglycerides and metabolizing them over several weeks.

Advanced HI-EMT Technology

The EMS Body Sculpt series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.

MYOslim machine highlighting key specifications

The MYOslim machine features two therapies in a single procedure (EMS+RF) with a highest output working frequency of 200Hz+, 6500W high power output, and 15 Tesla high energy.

Touch-Controlled Display

The touch-controlled display simplifies device operation, offering clear visibility of information from various positions. The brightness is adjustable for different lighting conditions, and the screen guides you through the entire treatment process.

Real-time Monitoring and Guidance

During treatment, the display shows remaining time, utilized channels, treatment methods, applied types, attachments, and other necessary information for real-time monitoring and guidance.

Upgradeability

The EMS Body Sculpt series offers flexible upgrade options to meet future therapeutic needs.

Indications for Use

  • Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
  • Strengthening, toning, and firming of buttocks, thighs, and calves.
  • Improvement of muscle tone and firmness, for strengthening muscles in arms.

Operating Environment

The operating environment is crucial for the device's effectiveness and safety:

  • Clean and Hygienic Environment: Ensure the environment is clean to prevent contamination. Regular cleaning and disinfection of equipment and accessories are essential.
  • Appropriate Temperature and Humidity: Maintain temperature and humidity within the manufacturer's specified range. Extreme conditions can affect performance.
  • Adequate Lighting: Provide sufficient lighting for clear and correct operation, especially for precise procedures.
  • Good Ventilation: Ensure adequate air circulation to prevent harmful gas accumulation.

Patient Profile

This machine is suitable for adults seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies.

Description of the Device

The EMS Body Sculpt allows for easy adjustment of digital energy selection, treatment plans, or diagnostic procedures. Parameters can be manually adjusted via the touchscreen. You can also create tailored treatment plans by configuring age group and gender.

Contraindications

  • Wounds on the skin (avoiding wounds when using).
  • Patients with heart disease (e.g., arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Major surgery patients, diabetic patients.
  • Having any metal in the body.
  • People with cerebrovascular disease (stroke patients).

Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

2. Important Safety Instructions

DANGER

Risk of electric shock. Do not open the device casing. No user-serviceable parts inside. Refer servicing to qualified personnel only.

CAUTION

  • This device is for adult use only. Do not use on minors or individuals without a health clearance certificate.
  • Do not use if you have metal implants, heart disease, cancer, diabetes, or are pregnant/lactating/menstruating.
  • Remove all metal jewelry before operation. Avoid contact with open wounds.
  • Do not use on a full stomach. Allow at least 1 hour after meals and refrain from eating/drinking during and 1 hour post-treatment.
  • Never replace the treatment handle while the device is powered on. Always turn off the power and calibrate the handle before replacement.
  • Keep away from strong electromagnetic sources. Do not daisy-chain multiple devices on a single power outlet.
  • This product is intended to be used in dry areas only.

SAVE THESE INSTRUCTIONS

The CE symbol indicates "European Conformity", declaring conformity with all relevant EU health, safety, and environmental protection regulations.

3. Setup and Basic Operation

3.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

3.2 Device Start Up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

3.3 Navigation Controls

Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays various items and functions for easy operation.

3.4 Unit Settings

The machine's settings interface allows adjusting brightness, sound, and language options. The interface is simplified for easy operation. You only need to set the energy, frequency, and RF, then click start.

Video demonstrating the MYOslim machine's operation, including handle application and interface navigation.

4.1 Preparing the Therapy

  1. Communicate with patients.
  2. Ensure good health.
  3. Stay hydrated.
  4. Wear appropriate clothing.
  5. Avoid eating in large quantities.
  6. Familiarize yourself with the treatment process.
  7. Avoid drinking alcohol.

4.2 Placing the Handle

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. The machine can be equipped with various handles for different body areas:

  • Flat Handles: Suitable for flat areas such as the abdomen and hips.
  • Curved Handles: Suitable for curved body parts like the arms, legs, and side waist.
  • Cushion Handle: Used for specific areas like the pelvic floor.
Cushion handle attachment for the MYOslim machine

Image of the cushion handle attachment.

4. Maintenance

4.1 Daily Inspection

Regularly inspect instruments and components. Check if the power socket has a reliable connection to the ground. Verify that the power cord is not damaged before use, and stop using the instrument if it is damaged.

4.2 Cleaning

  • Device Surface: The machine's logo is silk-screen printed, and other parts are spray-painted. Wipe the surface with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents.
  • Accessories: Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak accessories in alcohol-based detergent; wipe with pure cotton material.

4.3 Fuse Replacement

The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse.

4.4 Storage and Transportation

  • Storage: Store the instrument in its original packaging box in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, and relative humidity should not exceed 93%. Avoid storing near flammable, explosive, or corrosive gases.
  • Transportation: The instrument, in its packaging, is suitable for road, railway, air, and water transportation. During loading and unloading, prevent severe vibration and shock. Protect from moisture and avoid contact with flammable and corrosive substances. Specific requirements are detailed in the order contract.

5. Troubleshooting

Fault Phenomenon Causes Exclusions and Workarounds
Device not working
  • Power plug is not inserted into the socket
  • Power switch not on
  • Power fuse failure
  • Check the power
  • Check the power switch
  • Replace the fuse
Handle not working Check the handle for loose connection Reseat the handle

6. Specifications

General Product Properties

  • Brand Name: MYOSLIM
  • Item Type: Epilator
  • Epilator Type: Photoepilators
  • Power Type: Electric
  • Power Source: Electric
  • Voltage: 110V / 220V
  • Use Areas: Bikini, Body, Underarm, Legs/Arms, Hands, Abdomen, Buttocks
  • Origin: Mainland China
  • Certification: CE, RoHS
  • High-concerned chemical: None
  • Handles: 2/4/5 handles optional

Functions

  • Shape
  • Slimming
  • Body shaping
  • Muscle building
  • Decellulisation
  • Skin tightening
  • Buttock Lifting
  • Cellulite reduction function (EM)

Package Information

  • Weight: 21.0 kg
  • Length: 25 cm
  • Width: 28 cm
  • Height: 29 cm
  • Processing Time: 7 days

Electromagnetic Compatibility (EMC)

Radiated Electromagnetic Field Immunity Test:

  • Port: Enclosure
  • Basic Standard: IEC 61000-4-3:2020
  • Test Level: 30V/m with 80% AM. 1kHz Modulation.
  • Standard Requirement: A
  • Tester: Sam Liu
  • Temperature: 25°C
  • Humidity: 54%

Test Equipment:

Description Manufacturer Model Identifier Cal. Date Cal. Due
Signal Generator IFA 2023B N/A 15/03/2022 14/03/2023
Power Amplifier AR 150W1000 N/A 15/03/2022 14/03/2023
Power Antenna AR 25S1G4A N/A 15/03/2022 14/03/2023

Block Diagram of Test Setup:

Block diagram of the electromagnetic compatibility test setup for the MYOslim machine.

Diagram illustrating the 7x4x3 chamber setup for EMC testing, including Power Amp, Signal Generator, EUT & Support, and Control Room components.

7. User Tips

  • Always ensure the skin is clean and dry before applying the handles for optimal contact and effectiveness.
  • Start with lower intensity settings and gradually increase as comfort allows.
  • Consistency is key for best results; follow the recommended treatment schedule.
  • Stay hydrated throughout your treatment period to support muscle function and overall well-being.
  • Consult the full user manual (PDF) for detailed instructions and personalized treatment plans.

8. Warranty and Support

Warranty Card Information

The machine can be replaced with a new one within 7 days from the date of purchase (with receipt) if it has an intact appearance. The main machine is guaranteed for one year (excluding fragile parts and other non-warranty scope or expired warranty period). Maintenance and updates are available, with appropriate fees charged. If the instrument breaks and needs repair, the buyer bears the return shipping cost within six months of purchase, and the seller bears the shipping cost. After six months, the buyer bears all shipping costs.

Warranty Exclusions

Free warranty service is not provided for failures caused by personal reasons, including:

  • Faults caused by unauthorized disassembly and modification of this product.
  • Faults caused by accidental fall.
  • Failure caused by lack of reasonable maintenance.
  • Failure to operate according to the correct instructions in the instruction manual.

Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

Additional Resources

A detailed user manual in PDF format is available for download. Please refer to this document for comprehensive instructions and further details: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.