JUNCTEK PLS500

Contents

JUNCTEK PLS500 Dual Channel Pulse PWM Signal Generator

User Manual

1. Product Overview

The PLS500 Pulse Signal Generator is a high-precision, multi-functional signal generation device featuring a wide frequency range (1 Hz-500 kHz) and fine step adjustment. It supports dual-channel independent or synchronized operation and is widely applicable in precision testing, motor control, pulse modulation, and related fields. The device is capable of flexibly generating pulse signals with adjustable frequency, duty cycle, phase, and dead time, providing stable and reliable performance for demanding applications.

Front view of the PLS500 Pulse Signal Generator
Figure 1: Front view of the PLS500 Pulse Signal Generator.
Diagram highlighting core performance features of the PLS500
Figure 2: Core performance features including high-frequency precision, duty cycle, phase control, and ultra-fast rise time.
Video 1: A short product demonstration of the PLS500 Pulse Signal Generator.

2. Setup

2.1 Package Contents

Verify that all items are present in the package:

  • PLS500 Main Unit × 1
  • Quick Start Guide × 1
  • 2-pin Green Terminal × 1
  • 3-pin Green Terminal × 1
Image showing the package contents of the PLS500
Figure 3: Package contents including the main unit, quick start guide, and green terminals.

2.2 Wiring Diagram

Connect the power supply and output terminals as shown in the diagram below. Ensure correct polarity for the input voltage.

Wiring diagram for the PLS500 Pulse Signal Generator
Figure 4: Wiring diagram showing input (DC5V~25V) and output terminals (OUT1, GND, OUT2).

2.3 Power Supply Requirements

Ensure the input voltage remains within DC 5-25 V. Exceeding this range may damage the device. Do not reverse the input polarity when the power supply is disconnected, as this may damage internal circuitry.

The device supports two power supply modes:

  • Internal Power Supply: Output voltage is adjustable from 5-24 V. This mode is for signal output only and does not support load-driving.
  • External Power Supply: Output voltage follows the input voltage (approximately 0.4 V lower) and provides limited load capability.
Diagram showing no-load and load mode output capabilities
Figure 5: Illustration of no-load mode (adjustable 5-24V output) and load mode (output voltage requires no adjustment, capable of driving loads).

3. Operating Instructions

3.1 Key and Control Description

The PLS500 features an intuitive interface with a rotary encoder and several buttons:

  • Rotary Encoder (with push function): Used to adjust values, select parameters, and confirm settings.
  • M Key: Short press to recall parameters; short press again to save parameters.
  • UP / DOWN Keys: Move up or down to select the parameter to be adjusted.
  • SET Key: Enter the system settings menu.
  • LEFT / RIGHT Keys: Move the cursor left or right to select the digit position. Short press to switch frequency units between Hz and kHz.
  • MOD Key: Switch between interfaces: PWM Interface → PWM Sync Interface (Normal/Complementary) → CH1 Pulse Interface → CH2 Pulse Interface.
  • OUT Key: Turn output ON or OFF. ON indicates output enabled; OFF indicates output disabled. Long press to lock the keypad.
Diagram detailing operational experience with the 1.8-inch color display, encoder knob, and MOD/OUT keys
Figure 6: Operational controls including the 1.8-inch color display, encoder knob, and function buttons.

3.2 PWM Interface (Independent Channels)

In this mode, CH1 and CH2 can be configured independently.

  • Frequency Setting: Short press the rotary encoder to select the parameter. Use UP/DOWN keys to select CH1/CH2 frequency. Use LEFT/RIGHT keys to position the cursor, rotate the encoder to adjust the value, then short press again to confirm.
  • Duty Cycle Setting: Follow the same procedure as frequency setting to adjust CH1/CH2 duty cycle.
  • Output Voltage Adjustment (Internal Power Mode): Select the output voltage parameter and adjust the voltage value using the rotary encoder.
  • Output Control: Short press the OUT key to enable or disable signal output.

3.3 PWM Synchronization Interface

Short press the MOD key repeatedly to switch to the PWM synchronization interface. In this interface, CH1 and CH2 operate synchronously with identical frequency and duty cycle. Both Normal Mode and Complementary Mode are supported.

3.3.1 Normal Mode

Adjust frequency, duty cycle, output voltage, and phase angle using the rotary encoder and navigation keys as described in section 3.2.

3.3.2 Complementary Mode

Adjust frequency, duty cycle, output voltage, and dead time using the rotary encoder and navigation keys. Dead time can be set from 0-91 ns (7 ns step) or 0.1-20.0 µs (0.1 µs step).

Diagram showing dual-channel independent, synchronous, and complementary modes
Figure 7: Dual-channel operation modes: Independent, Synchronous, and Complementary.
Diagram illustrating precise dead time adjustment
Figure 8: Illustration of precise dead time adjustment in pulse waveforms.

3.4 CH1/CH2 Pulse Interface (Programmable Time Waveform Control)

This interface allows for precise control over pulse timing parameters:

  • T0 Delay Time Setting: Defines the delay from the initial idle state to the first valid pulse output (0.000s-60.000s, min step 0.001s).
  • T1 Positive Pulse Width Setting: Controls the duration of the high-level state (0.000s-60.000s, min step 0.001s).
  • T2 Negative Pulse Width Setting: Controls the duration of the low-level state (0.000s-60.000s, min step 0.001s).
  • Pulse Count (Num) Setting: Set the number of output pulses (1-60,000) or continuous output (∞). For non-continuous output, after setting the pulse count, short press the rotary encoder to remove the cursor. Rotating the encoder will then trigger pulse output.
  • Output Voltage Adjustment (Internal Power Mode): Adjust output voltage as required.
  • Output Control: Short press the OUT key to enable or disable output.

The operation and parameters for CH2 Pulse Interface are identical to CH1.

Diagram explaining T0, T1, T2 programmable time-domain waveform control
Figure 9: T0, T1, T2 parameters for professional timing control.

3.5 System Settings Menu

Press the SET key to enter the system settings menu. Available settings include:

  • Language: Chinese / English selectable.
  • Brightness: Adjustable from 1% to 100%.
  • Auto Screen OFF: Disable or set 1-60 seconds of inactivity before the screen turns off.
  • Vout Power Supply: Configure internal or external power supply mode.
  • PWM Mode: Select Normal or Complementary mode.
  • Lower Frequency: Adjustable within 0-500 kHz.
  • Upper Frequency: Adjustable within 0-500 kHz.
  • Lower Duty: Adjustable within 0%-100%.
  • Upper Duty: Adjustable within 0%-100%.
  • Restore Defaults: Select Yes / No to reset all parameters to factory defaults.

4. Maintenance

To ensure the longevity and optimal performance of your PLS500 Pulse Signal Generator, follow these maintenance guidelines:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Operating Environment: Avoid use in humid environments, high temperatures, or areas with strong electromagnetic interference.

5. Troubleshooting

If you encounter issues with your PLS500, consider the following:

  • No Output: Ensure the OUT key is pressed to enable output (display shows "ON"). Check all wiring connections, especially power supply and output terminals.
  • Incorrect Output: Verify that the frequency, duty cycle, phase, and dead time settings are correctly configured for your application. Check the input voltage is within the specified range.
  • Device Not Powering On: Confirm the power supply is connected correctly and providing DC 5-25V. Check for reversed input polarity.
  • Unresponsive Controls: If the keypad is locked, long press the OUT key to unlock it. If issues persist, try restoring factory defaults via the System Settings menu.
  • Output Protection: Do not short-circuit the output terminals, as this may cause malfunction or safety hazards.

6. Specifications

The following table details the technical specifications of the PLS500 Pulse Signal Generator:

Parameter Item Specification
Output Channel CH1 + CH2
Operating Voltage DC 5-24V
Frequency Range 1Hz-500kHz
Step 1Hz
Frequency Accuracy (1kHz-10kHz) ±0.2‰
Frequency Accuracy (10kHz-50kHz) ±0.4‰
Frequency Accuracy (50kHz-500kHz) ±2‰
Duty Cycle Range 0-100% (0.1% step)
Phase Range 0°-359° (1° step)
Rise Time 10ns
T0 Delay Output Time 00.000s-60.000s (minimum step 0.001s)
T1 Positive Pulse Width 00.000s-60.000s (minimum step 0.001s)
T2 Negative Pulse Width 00.000s-60.000s (minimum step 0.001s)
Pulse Count 1-60000 or ∞ (continuous)
Dead Time 0-91 ns (7 ns step); 0.1-20.0 µs (0.1 µs step)
PWM Mode Normal/Complementary (with dead zone)
Operation Mode Encoder + button
Display 1.8-inch color screen
Product Dimensions 108 × 63 × 24 mm
Hole Size 100 × 56 mm
Product Specifications Table for PLS500
Figure 10: Summary of PLS500 product specifications.

7. User Tips

No specific user tips are available from provided reviews or Q&A content at this time. Please refer to the operating instructions for optimal use.

8. Warranty and Support

For detailed warranty information and technical support, please refer to the official user manual PDF provided by the manufacturer. You can typically find this document on the product's support page or by contacting the seller directly. A digital version of the user manual is available at: PLS500 User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.