1. Introduction
This manual describes the assembly, installation, operation, and troubleshooting of the Y&H Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
1.1. Product Overview
The Y&H Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.
The inverter supports battery-free operation and is compatible with 48V lead-acid and lithium batteries. It includes an MPPT 120A solar charger and offers both on-grid and off-grid capabilities.

Image: Y&H 6.2KW 48V Hybrid Solar Inverter highlighting PV Input Voltage (60-500V), DC Battery Voltage (48V), MPPT Charging Current (120A), and AC Input/Output (220V).
1.2. Key Features
- Pure sine wave inverter output.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Auto restart while AC is recovering.
- Overload, Over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- RS485 communication for BMS and charging current adjustment based on battery demand.
- Can operate with or without batteries.
- Intelligent fan speed adjustment based on temperature, load, and charging current.
- Built-in MPPT with an operating voltage range of 55V-450V and open circuit voltage of 500Voc.
- RGB lamp indicating inverter status with different colors.
- WIFI remote monitoring (optional).
- Offline upgrade function via COM port.
- Grid-connected capability.
- Built-in anti-dust kit for harsh environments.
- Enhanced user experience in battery-free mode when powering loads.
- Equipped with lithium battery activation function.

Image: Y&H 6.2KW Hybrid Solar Inverter (Upgraded) highlighting 7 Core Upgrades including Offline COMM Port, PV Input 18A-27A (6200W), No Phone Charging Interference, One-Click LCD Display, Wi-Fi App, Bigger PV Load Without Battery, and Low Current Mains Charging.
1.3. Basic System Architecture
The inverter/charger can power various appliances in home or office environments, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners. A typical setup includes the solar inverter, solar panels (PV modules), a battery bank (optional), and a generator or utility connection.

Image: Diagram illustrating the Hybrid Power System, showing connections between Solar Power, Solar Inverter, Generator/Utility, External Battery Packs, and Home Appliances.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Please strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

Image: Icons representing comprehensive protection features: Short Circuit, Over-Load, Over Voltage, Over-Temperature, Over Current, Backfill, Under Voltage, and Over Charge Protection.
3. Setup (Installation)
3.1. Unpacking and Inspection
Before installation, inspect the unit. Ensure nothing inside the package is damaged. The package should contain:
- The unit x 1
- User manual x 1
3.2. Preparation
Before connecting all lines, remove the screws under the machine and remove the bottom cover plate.3.3. Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Ensure other objects and surfaces are left with enough space from the machine to ensure adequate heat dissipation and room to remove wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M6 screws.

Image: Y&H Inverter with dimensions (50cm/19.68in height, 41.5cm/16.34in width) and a Solar Battery. Text describes Battery-Free Operation: Inverter can supply power to loads directly from PV array or AC grid without a connected battery. For Li-ion batteries in sleep mode, a dual-trigger mechanism activates it via mains power or photovoltaic power.
3.4. Port Introduction
Familiarize yourself with the inverter's ports and indicators:
- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- Main output
- Second output
- Battery input
- PV input
- Anti dust kit
- Battery communication/RS-485 port
- WIFI communication/RS-232 port

Image: Diagram showing the front and bottom views of the inverter with numbered labels for each port and indicator, corresponding to the list above.
3.5. Battery Connection
CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. Refer to the table below for typical amperage for fuse or breaker size.
WARNING! All wiring must be performed by qualified personnel. Use appropriate cables for battery connection to reduce risk of injury.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.2KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps for battery connection:
- Remove 18 mm of insulation sleeve for positive and negative conductors.
- Suggest using bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram.
- Insert the battery wires flatly into the inverter's battery connectors. Ensure bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and inverter/charger, and that conductors are tightly screwed into the battery terminals.
WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
3.6. AC Input/Output Connection
CAUTION!! Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent. Recommended AC breaker specs: 32A for 4.2KW and 50A for 6.2KW.
CAUTION!! There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel. Use appropriate cables for AC input connection.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 4.2KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps for AC input/output connection:
- Before making AC input/output connections, open the DC protector or disconnector first.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to polarities indicated on the terminal block and tighten the terminal screws. (L→LINE (brown or black), N→Neutral (blue))
- WARNING: Be sure that the AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to polarities indicated on the terminal block and tighten terminal screws. (L→LINE (brown or black), N→Neutral (blue))
- Ensure the wires are securely connected.
CAUTION: Appliances like air conditioners require 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter/charger may trigger an overload fault to protect the appliance, but damage can still occur.
3.7. PV Connection
CAUTION: Before connecting to PV modules, install a DC circuit breaker separately between the inverter and PV modules.
WARNING! Use appropriate cable for PV module connection to ensure system safety and efficient operation.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 4.2KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection
When selecting PV modules, consider these parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| IMax.PV | 27A | |
PV Module Wire Connection
Follow these steps for PV module connection:
- Remove 10 mm of insulation sleeve for positive and negative conductors.
- Suggest using bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
3.8. Final Assembly
After connecting all wirings, replace the bottom cover by screwing two screws.
3.9. Communication Connection
Wi-Fi Cloud Communication (Optional)
Use the supplied communication cable to connect the inverter and Wi-Fi module. Download the APP from the APP store and refer to the "Wi-Fi Plug Quick Installation Guideline" to set up the network and register. The inverter status will be shown on the mobile phone APP or computer webpage.
GPRS Cloud Communication (Optional)
Use the supplied communication cable to connect the inverter and GPRS module, and then apply external power to the GPRS module. Download the APP from the APP store and refer to the "GPRS RTU Quick Installation Guideline" to set up the network and register. The inverter status will be shown on the mobile phone APP or computer webpage.
Battery Communication and Setting of Lithium Battery
The communication between the battery and the inverter can be realized through the battery communication interface, allowing the inverter and the lithium battery to exchange information (Baud rate: 9600).
If using a lithium battery, only lithium batteries matched with BMS communication protocol are allowed.
- Connect the battery according to the recommended battery cable specifications.
- Insert the ring terminal of the battery cable into the inverter's battery connector flatly, ensuring bolts are tightened with a torque of 2-3 Nm. Verify correct polarities.
- Connect one side of the RJ45 cable to the BMS communication port of the inverter.
- Insert the other side of the RJ45 cable into the RS485 communication port on the lithium battery.
NOTE: If you choose a lithium battery, ensure to connect the battery and inverter with the BMS communication cable, and select the battery type as "LIB-485" mode.
The inverter BMS port's PIN definition:
| Pin number | Port definitions |
|---|---|
| 1 | RS485B |
| 2 | RS485A |
| 3 | NG |
| 4 | NG |
| 5 | NG |
| 6 | NG |
| 7 | RS485A |
| 8 | RS485B |
To communicate with the lithium battery BMS, press and hold the "ENTER" button, then set the battery type as "LIB-485" in program 05. Then select the matching battery protocol in Program 43.
CAUTION: When the battery type is set to "LIB-485", setting items 12, 13, and 29 are displayed in percentage.
4. Operation
4.1. Power ON/OFF
Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2. Operation and Display Panel
The operation and display panel on the front of the inverter includes three indicators, four function keys, and an LCD display, showing operating status and input/output power information.
LED Indicators
| Indicator | Color | State | Message |
|---|---|---|---|
| INV/AC | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3. LCD Display Icons
The LCD displays various icons to indicate the inverter's status and information:
Input Source Information
- AC Input Icon: Indicates the AC input is connected.
- PV Input Icon: Indicates the PV input is connected.
- Input Voltage/Frequency/PV Voltage/Charger Current/Charger Power/Battery Voltage: Displays numerical values for these parameters.
Configuration Program and Fault Information
- Setting Programs Icon: Indicates the setting programs.
- Warning and Fault Codes Icon: Indicates warning and fault codes.
- Warning: Flashing with warning code.
- Fault: Lighting with fault code.
Output Information
- Output Voltage/Frequency/Load Percent/Load in VA/Load in Watt/Discharging Current: Displays numerical values for these parameters.
Battery Information
- Battery Icon: Indicates battery status.
Load Information
- Overload Icon: Indicates overload.
Mode Operation Information
- Mains Connection Icon: Indicates unit connects to the mains.
- PV Panel Connection Icon: Indicates unit connects to the PV panel.
- AC Bypass Icon: Indicates load is supplied by utility power.
- Utility Charger Circuit Icon: Indicates the utility charger circuit is working.
- DC/AC Inverter Circuit Icon: Indicates the DC/AC inverter circuit is working.
Mute Operation
- Mute Icon: Indicates unit alarm is disabled.
4.4. LCD Setting
To enter setting mode, press and hold the "ENTER" button for 3 seconds. Use the "UP" or "DOWN" buttons to select programs, then "ENTER" to confirm or "ESC" to exit.
Detailed settings for various programs (00-45) are available in the PDF manual, covering aspects like output source priority, charging current, AC input voltage range, power saving mode, battery type, auto restart functions, output frequency, output voltage, utility charging current, voltage point settings, lithium battery protocol, delayed grid access, and maximum second load.
4.5. Operating Mode Description
The inverter supports several operating modes:
- Standby Mode: The inverter is not turned on, but can charge the battery without AC output. No output is supplied by the unit, but it can still charge batteries.
- Line Mode: The unit provides output power from the mains and can also charge the battery.
- Battery Mode: The unit provides output power from the battery and solar power.
- Grid-Tie Operation: When working in Grid-Tie mode, the unit will flash 3S/times.
4.6. RGB Light (Optional)
- Inverter State: Green light
- Utility State: Blue light
- Failure State: Red light
4.7. Battery Equalization Description
Equalization reverses the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, which can reduce battery capacity. It is recommended to equalize batteries periodically.
How to Apply Equalization Function
Enable the battery equalization function in monitoring LCD setting program 30. Then, apply this function by:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize
In float stage, when the setting equalization interval is reached, or equalization is activated immediately, the controller will enter the Equalize stage.
Equalize Charging Time and Timeout
In Equalize stage, the controller charges the battery until it reaches the equalization voltage. Constant-voltage regulation maintains this voltage. The battery remains in Equalize stage until the set equalized time is reached. If the battery voltage doesn't rise to the equalization voltage point when the time expires, the charge controller extends the time until the voltage is achieved. If the voltage is still low after the timeout, the controller stops equalization and returns to float stage.
4.8. Mains and Lithium Battery Activation Function
- After 90 seconds of mains power connection to the inverter, the machine connects to the mains and starts to work.
- If the inverter is in lithium battery mode (item 05 is Llb or Llb-485), and the mains are connected but the battery is not, the mains activation function is automatically enabled.
5. Maintenance
5.1. Clearance and Maintenance for Anti-Dust Kit
Every inverter comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and activates an internal thermal sensor to adjust internal temperature. This kit prevents dust from entering the inverter, increasing product reliability in harsh environments.
Follow these steps for maintenance:
- Loosen the screw in a counterclockwise direction on the top of the inverter.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- After cleaning, re-assemble the dust-kit back into the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
6. Troubleshooting
6.1. Fault Reference Code
The inverter displays specific fault codes on the LCD to indicate issues. Refer to the table below for common fault codes and their descriptions.
| Fault Code | Fault Event |
|---|---|
| 01 | Fan is locked when inverter is off. |
| 02 | Over temperature |
| 03 | Battery voltage is too high |
| 04 | Battery voltage is too low |
| 05 | Output short circuited or over temperature is detected by internal converter components. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 51 | Over current or surge |
| 52 | Bus voltage is too low |
| 53 | Inverter soft start failed |
| 55 | Over DC voltage in AC output |
| 57 | Current sensor failed |
| 58 | Output voltage is too low |
| 59 | PV voltage is over limitation |
6.2. Warning Indicator
The inverter provides audible alarms and icon flashing for various warning conditions.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| 16 | AC voltage is over limitation | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| 6P | Battery is not connected | None |
6.3. General Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Input voltage is displayed as 0 on the LCD and green LED is flashing. | Input protector is tripped | Check if AC breaker is tripped and AC wiring is connected well. | |
| Mains exist but the unit works in battery mode. | Green LED is flashing. | Insufficient quality of AC power. (Shore or Generator) | 1. Check if AC wires are too thin and/or too long. 2. Check if generator (if applied) is working well or if input voltage range setting is correct. (UPS/Appliance) |
| Green LED is flashing. | Set "Solar First" as the priority of output source. | Change output source priority to Utility first. | |
| When the unit is turned on, internal relay is switched on and off repeatedly. | LCD display and LEDs are flashing | Battery is disconnected. | Check if battery wires are connected well. |
| Fault code 07 | Overload error. The inverter is overload 110% and time is up. | Reduce the connected load by switching off some equipment. | |
| Fault code 05 | Output short circuited. | Check if wiring is connected well and remove abnormal load. | |
| Fault code 02 | Temperature of internal converter component is over 120°C. Internal temperature of inverter component is over 100°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. | |
| Buzzer beeps continuously and red LED is on. | Fault code 03 | Battery is over-charged. The battery voltage is too high. | Return to repair center. Check if spec and quantity of batteries are meet requirements. |
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06/58 | Output abnormal (Inverter voltage below than 190Vac or is higher than 260Vac) | 1. Reduce the connected load. 2. Return to repair center | |
| Fault code 08/09/53/57 | Internal components failed. | Return to repair center. | |
| Fault code 51 | Over current or surge. | Restart the unit, if the error happens again, please return to repair center. | |
| Fault code 52 | Bus voltage is too low. | ||
| Fault code 55 | Output voltage is unbalanced. |
7. Specifications
7.1. Table 1 Line Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±7V (UPS); 90Vac±7V (Appliances) | |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliance) | |
| High Loss Voltage | 280Vac±7V | |
| High Loss Return Voltage | 270Vac±7V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.2. Table 2 Inverter Mode Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Rated Output Power | 4.2KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 93% | |
| Overload Protection | 3s@≥150% load; 30s@101%~150% load | |
| Surge Capacity | 2* rated power for 3 seconds | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| Low DC Warning Voltage @load < 50% | 22.0Vdc | 44.0Vdc |
| Low DC Warning Voltage @load ≥ 50% | 21.0Vdc | 42.0Vdc |
| Low DC Warning Return Voltage @load < 50% | 22.5Vdc | 45.0Vdc |
| Low DC Warning Return Voltage @load ≥ 50% | 22.0Vdc | 44.0Vdc |
| Low DC Cut-off Voltage @load < 50% | 20.5Vdc | 41.0Vdc |
| Low DC Cut-off Voltage @load ≥ 50% | 20.0Vdc | 40.0Vdc |
| High DC Recovery Voltage | 32Vdc | 62Vdc |
| High DC Cut-off Voltage | 33Vdc | 63Vdc |
| No Load Power Consumption | 25W | 50W |
| Saving Mode Power Consumption | < 10W | < 15W |
7.3. Table 3 Two Load Output Power
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Full Load | 4200W | 6200W |
| Maximum Main Load | 4200W | 6200W |
| Second Load Range | 840W~2940W | 1240W~4340W |
| Main Load Cut Off Voltage | 22VDC | 44VDC |
| Main Load Return Voltage | 26VDC | 52VDC |
7.4. Table 4 Charge Mode Specifications
| Utility Charging Mode | 4.2KW | 6.2KW |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 100Amp (@VI/P=230Vac) | |
| Bulk Charging Flooded Battery Voltage | 29.2 | 58.4 |
| AGM / Gel Battery | 28.2 | 56.4 |
| Floating Charging Voltage | 27Vdc / 54Vdc (depending on model) | |
| MPPT Solar Charging Mode | ||
| Max. PV Array Power | 6200W | 8000W |
| Nominal PV Voltage | 240Vdc | 360Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 120Amp | |
7.5. Table 5 General Specifications
| INVERTER MODEL | 4.2KW | 6.2KW |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C~60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 423×344×112 | |
| Net Weight, kg | 7.2 | 8.2 |
7.6. Appendix: Approximate Back-up Time Table
The backup time depends on the quality, age, and type of battery. Battery specifications may vary by manufacturer.
| Model | Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|---|
| 4.2KW | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 | |
| 3600 | 25 | 60 | |
| 4200 | 22 | 53 | |
| 6.2KW | 500 | 613 | 1288 |
| 1000 | 268 | 613 | |
| 1500 | 158 | 402 | |
| 2000 | 111 | 271 | |
| 2500 | 90 | 215 | |
| 3200 | 76 | 182 | |
| 3500 | 65 | 141 | |
| 4000 | 50 | 112 | |
| 4500 | 44 | 100 | |
| 5000 | 40 | 90 | |
| 6200 | 36 | 80 |
8. User Tips
- Always confirm the correct voltage requirements for your specific setup with the seller or a qualified electrician before purchasing and installation to ensure compatibility and optimal performance.
- Ensure the product packaging is intact upon arrival. Proper packaging helps protect the inverter during transit, minimizing the risk of damage.
- For complex wiring diagrams or specific setup instructions not fully detailed in this manual, refer to the official PDF user manual available from the seller.
9. Warranty and Support
This product is covered by a manufacturer's warranty. For warranty claims, technical support, or service, please contact your local dealer or the service center where the product was purchased. Ensure you retain your proof of purchase for any warranty-related inquiries.
If you encounter persistent issues after following the troubleshooting guide, it is recommended to contact qualified service personnel or return the inverter/charger to the local dealer or service center for maintenance.