Introduction
This manual provides detailed instructions for the safe and effective operation of your Digital Handheld Anemometer. Please read this manual thoroughly before use and keep it for future reference.

Features and Characteristics
- Anti-interference touch buttons
- Wind speed measurement
- Air volume measurement
- Temperature measurement
- Compact and waterproof design
- Current, maximum, and minimum wind speed display
- Low battery indication function
- Backlight display function
- Rechargeable lithium battery with Type-C interface
- Optional automatic power-off function
Setup
Battery Installation and Charging
The anemometer uses a rechargeable lithium battery (Model: 60204, 400mAh). Before initial use, or if the battery is depleted, install and charge the battery.
- Unscrew the screws on the battery cover located on the back of the device.
- Connect the battery, ensuring correct polarity (connect wires of the same color together).
- Replace the battery cover and secure the screws.
- Connect the device to a power source using a Type-C USB cable for charging. A full charge typically takes 2 to 3 hours.

Initial Power On and Automatic Power-Off Setting
- **Power On/Off**: Press and hold the Power On/Off Button (①) for more than 1 second to turn on the device. The screen will fully display upon startup. Briefly press the Power On/Off Button (①) again to turn off the device.
- **Automatic Power-Off Mode**:
- In the power-off state, press and hold the Data Hold and Backlight Button (⑥) for 5 seconds. The main display on the LCD will show the "ON" symbol.
- Release the button, then briefly press the Set Air Volume Area Key and Temperature Unit Switch Button (⑤) to toggle between "ON" (enabling automatic power-off) and "OFF" (disabling automatic power-off).
- After selecting your desired mode, briefly press the Data Hold and Backlight Button (⑥) to enter the power-on state.
- When automatic power-off is enabled, the LCD screen will display the " ⏱ " symbol, indicating that the device will automatically power off after approximately 5 minutes of inactivity. This symbol will not be displayed when automatic power-off is disabled.
Operating Instructions
Familiarize yourself with the device's buttons:

- **① Power On/Off Button**: Turns the device on or off.
- **② Wind Speed/Air Volume Function Switch Button**: Toggles between wind speed and air volume measurement modes.
- **③ Wind Speed Maximum/Minimum/Real-time Value Switch Button**: Cycles through maximum, minimum, and real-time (current) values for wind speed or air volume.
- **④ Wind Speed/Air Volume Unit Switch Button**: Changes measurement units.
- **⑤ Set Air Volume Area Key and Temperature Unit Switch Button**: Used for setting air volume area and switching temperature units.
- **⑥ Data Hold and Backlight Button**: Briefly press for data hold; press and hold for 3 seconds to activate/deactivate backlight.
Measurement Functions
- **Switching Between Wind Speed and Air Volume**: Briefly press Button ② to switch between wind speed and air volume measurement functions.
- **Viewing Max/Min/Real-time Values**: Briefly press Button ③ to cycle through the maximum, minimum, and real-time (current) values of wind speed or air volume.
- **Changing Wind Speed Units**: While in wind speed measurement mode, briefly press Button ④ to switch between units: m/s, km/h, ft/min, knots, and MPH.

The anemometer supports five common wind speed units with their respective measurement ranges. - **Changing Air Volume Units**: While in air volume measurement mode, briefly press Button ④ to switch between units: CFM, CMS, and CMM.
- **Switching Secondary Display Area Units (Air Volume)**: In air volume mode, press and hold Button ④ to switch between secondary display area units: square meters (m²) and square feet (ft²).
- **Changing Temperature Units**: In wind speed mode, briefly press Button ⑤ to toggle between Celsius (°C) and Fahrenheit (°F) for the secondary temperature display.
- **Setting Air Volume Area**:
- In air volume mode, briefly press Button ⑤. The "AREA" symbol will flash on the display.
- Press the "UNIT" button (part of ④) to select the desired digit position (hundreds, tens, units, decimal).
- Press the "MAX MIN" button (part of ③) to adjust the numeric value (0-9).
- After adjusting the area value, briefly press Button ⑤ again to confirm and exit the area setting.
- **Data Hold**: Briefly press Button ⑥ to hold the current measurement data on the display. Press again to release.
- **Backlight Control**: Press and hold Button ⑥ for 3 seconds to activate or deactivate the display backlight.
Maintenance
- **Cleaning**: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- **Storage**: When not in use for extended periods, store the anemometer in a cool, dry place away from direct sunlight and extreme temperatures.
- **Battery Care**: Recharge the battery regularly, even if not in frequent use, to maintain its lifespan. Avoid fully discharging the battery for long periods.
- **Sensor Protection**: Keep the wind impeller free from dust, debris, and obstructions to ensure accurate measurements.
Troubleshooting
If you encounter any issues with your anemometer, please consider the following:
- **Device not powering on**: Ensure the battery is correctly installed and sufficiently charged.
- **Inaccurate readings**: Check if the impeller is obstructed or damaged. Ensure the device is held correctly in the airflow.
- **Display issues**: If the display is dim, activate the backlight (press and hold Button ⑥ for 3 seconds) or recharge the battery.
- **Automatic power-off unexpected**: Verify the automatic power-off setting (refer to "Initial Power On and Automatic Power-Off Setting" in the Setup section).
For persistent problems, please contact customer support with the details outlined in the "Warranty and Support" section.
Specifications
| Parameter | Range | Resolution | Accuracy |
|---|---|---|---|
| Wind Speed Measurement | |||
| m/s | 0.3 ~ 40 | 0.1 | ±5% |
| ft/min | 59 ~ 7874 | 19 | |
| Knots (kt) | 1 ~ 77 | 0.2 | |
| km/h | 2 ~ 144 | 0.3 | |
| mph | 1 ~ 89 | 0.2 | |
| Temperature Range | |||
| °C | -10 ~ 45°C | 0.2 | ±2°C |
| °F | 14 ~ 113°F | 0.36 | ±3.6°F |
| Air Volume Index | |||
| CMM (M³/MIN) | 0 ~ 999900 | 0.001 ~ 100 | 0.001 ~ 9999 |
| CMS (M³/S) | 0 ~ 999900 | 0.001 ~ 100 | 0.001 ~ 9999 |
| CFM (FT³/MIN) | 0 ~ 999900 | 0.001 ~ 100 | 0.001 ~ 9999 |
| Battery | Lithium Battery Model: 60204 (400mAh). Takes 2 to 3 hours to fully charge. | ||
| Operating Temperature | -10°C ~ 45°C (14°F ~ 113°F) | ||
| Relative Humidity | ≤90%RH | ||
| Storage Temperature | -20°C ~ 50°C (-4°F ~ 122°F) | ||
| Current Consumption | Approximately 3mA | ||
| Dimensions | 208.5 x 72 x 35mm (8.2 x 2.83 x 1.37 inches) | ||
| Weight | Approximately 142g (including battery) | ||

User Tips
- For accurate wind speed readings, ensure the impeller is facing directly into the airflow.
- When measuring air volume, accurately setting the area value is crucial for correct calculations.
- The backlight feature is useful in low-light conditions but consumes more battery; use it judiciously.
- Consider using a tripod for stable and continuous wind measurements, especially in outdoor environments.

Warranty and Support
For any problems or concerns, please contact our customer support team for a prompt response. To ensure immediate assistance, please provide the following information:
- Order Number
- Platform of Your Purchase
- Full Model Number (e.g., 5000D)
- Description of the Problem (attaching videos or photos can help us troubleshoot the problems even faster)
Customer Support Email: AFTERSALES1010@HOTMAIL.COM
A PDF version of this user manual is available for download: User Manual (PDF)