1. Introduction
This PowMr Hybrid Solar Inverter is a multi-function inverter/charger, combining the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display and user-configurable button operations for settings such as battery charging current, AC/solar charger priority, and acceptable input voltage, making it adaptable for various applications.
1.1 Key Features
- Pure sine wave inverter output.
- Configurable input voltage range for home appliances and personal computers via LCD setting.
- Configurable battery charging current based on applications via LCD setting.
- Configurable AC/Solar Charger priority via LCD setting.
- Compatible with mains voltage or generator power.
- Automatic restart while AC is recovering.
- Overload, over temperature, and short circuit protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Supports parallel operation for up to 9 units.
1.2 Basic System Architecture
The inverter/charger is designed to integrate into a complete solar energy system. A typical setup includes:
- Generator or Utility: Provides backup or supplemental power.
- PV Modules: Solar panels for generating electricity.
- Inverter/Charger: The core unit managing power flow.
- External Battery Packs: For energy storage.
- Home Appliances: Various loads such as lights, fans, refrigerators, and air conditioners.

2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable sizes. It is very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool, causing sparks or short circuits in batteries or other electrical parts, which could lead to an explosion.
- Please strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- A 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations for installing this inverter.
- NEVER cause AC output and DC input to be short-circuited. Do NOT connect to the mains when DC input short circuits.
- Warning: Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Setup (Installation)
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit for any damage. The package should contain the following items:
- One (1) Inverter unit
- One (1) User manual
- One (1) Parallel communication cable
- Two (2) Male MC4 connectors & Two (2) Female MC4 connectors
- One (1) Current sharing cable
- Two (2) Expansion screws
- One (1) Battery fuse
3.2 Preparation
Before making any connections, remove the bottom cover of the inverter by unscrewing the five retaining screws.
3.3 Mounting the Unit
When selecting a mounting location, consider the following:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install the inverter at eye level for easy readability of the LCD display.
- Ensure proper air circulation for heat dissipation: allow approximately 20 cm clearance to the sides and 50 cm above and below the unit.
- The ambient temperature should be between -10°C and 50°C for optimal operation.
- The recommended installation position is vertically on a wall.
- Keep other objects and surfaces clear to guarantee sufficient heat dissipation and space for wiring.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing three screws. Use M6*80mm expansion bolts for suspending and securing the equipment from above. Use M4 or M5 screws to secure the equipment from below inside the terminal cover.
3.4 Battery Connection
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION: Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for battery connection. To reduce the risk of injury, use the proper recommended cable and terminal size.
| Rated Capacity | Typical Amperage | Battery Capacity | Wire Size | Cable (mm²) | Terminal D(mm) | Terminal L(mm) | Torque Value |
|---|---|---|---|---|---|---|---|
| 11KW | 228A | 250Ah | 1*3/0AWG | 85 | 8.4 | 54 | 5 Nm |
CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between the battery and inverter.
Follow these steps for battery connection:
- Assemble battery ring terminals based on recommended cable and terminal size.
- Insert the battery wires flatly into the inverter's battery connectors. Ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and the inverter/charger, and ensure conductors are tightly screwed into the battery terminals.

3.5 AC Input/Output Connection
WARNING: Be sure that the AC power source is disconnected before attempting to hardwire it to the unit.
All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for AC input connection. To reduce the risk of injury, use the proper recommended cable size.
| Rated Capacity | Gauge | Torque Value |
|---|---|---|
| 11KW | 8 AWG | 1.4~1.6 Nm |
CAUTION:
- Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be disconnected for maintenance and fully protected from over-current. The recommended breaker spec is 63A for a 48V system.
- There are two terminal blocks marked "IN" and "OUT". Do NOT mis-connect input and output connectors.
- Appliances such as air conditioners require at least 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter/charger may trigger an overload fault and cut off output, but internal damage to the air conditioner may still occur.
Follow these steps to implement AC input/output connection:
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten the phase L and N conductors by 3mm.
- Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Ensure the PE protective conductor (Ground) is connected first.
Wiring Order: Ground (yellow-green); L (brown or black); N (blue)

3.6 PV Connection
All wiring must be performed by qualified personnel. It is crucial for system safety and efficient operation to use appropriate cables for PV module connection. To reduce the risk of injury, use the proper recommended cable size.
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
When choosing the right PV module, consider the following:
- The open circuit voltage (Voc) of the PV modules must not exceed the maximum PV array open circuit voltage of the inverter (500Vdc).
- The maximum supply voltage of the PV modules should be close to the optimal PV access voltage range of the inverter (360-430V) for best performance.
- If one PV module cannot meet this requirement, connect multiple PV modules in series.
| Parameter | Value |
|---|---|
| PV Charging Mode | Dual MPPT |
| MAX. PV Input Power | 2*7500W |
| MPPT Tracking Range | 90~500Vdc |
| Operating Voltage | 360~430V |
| MAX. PV Input Voltage | 500Vdc |
| PV Max Input Current | 27A/27A |
| MAX. PV Charging Current | 150A |
Follow these steps to implement PV module connection:
- Check the input voltage of the PV array modules. This system uses two strings of PV array. Ensure the maximum current load of each PV input connector is 27A/27A.
- Disconnect the circuit breaker and switch off the DC switch.
- Assemble the provided PV connectors with PV modules.
Components for PV connectors and Tools:
- Female connector housing
- Female terminal
- Male connector housing
- Male terminal
- Wire stripper, crimping tool, and spanner
Connector Assembly Process:
- Strip 10mm of insulation from both ends of the cable, being careful not to nick conductors.
- Insert the stripped cable into the male terminal and crimp it.
- Insert the assembled cable into the male connector housing and push the sealing ring into place.
- Repeat for female terminals and housings.
- Use two spanners to tightly screw the pressure dome onto the female and male connectors to ensure a secure and waterproof connection.
- Check the correct polarity of the wire from the PV modules and PV input connectors. Connect the positive pole (+) of the connection wire to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection wire to the negative pole (-) of the PV input connector.

3.7 Final Assembly
After connecting all wirings, install the bottom cover back by screwing the five screws.
3.8 Parallel Function Installation (Appendix I)
The PowMr Hybrid Solar Inverter supports parallel operation for up to 9 units, allowing for a total output of up to 55.8kW. This enables the creation of high-power energy systems for single-phase 230V or three-phase 400V configurations.
WARNING: Do not connect the current sharing cable between inverters that are in different phases. This may damage the inverters.
WARNING: Ensure all inverters share the same battery bank. Otherwise, the inverters will transfer to fault mode.
NOTE: For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the sides and 50 cm above and below each unit. Ensure all units are installed at the same level.
CAUTION: Install a breaker at the battery and AC input side to ensure the inverter can be securely disconnected for maintenance and fully protected from over-current.
Recommended Battery Capacity for Parallel Units (11KW model):
| Inverter Parallel Numbers | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
|---|---|---|---|---|---|---|---|---|
| Battery Capacity for 11KW | 500AH | 750AH | 1000AH | 1250AH | 1500AH | 1750AH | 2000AH | 2250AH |
Wiring Connection for Parallel Operation:
The cables of each inverter need to be connected together. Use a connector or bus-bar as a joint to connect the battery cables together, and then connect to the battery terminal. The cable size used from the joint to the battery should be X times the cable size in the tables above, where "X" indicates the number of inverters connected in parallel. The same principle applies to AC input and output wiring.
WARNING: Ensure all output N wires of each inverter are connected at all times. Otherwise, it will cause an inverter fault (error code #72).
PV Connection for Parallel Operation:
NOTE: Each inverter should be connected to an independent photovoltaic array. Multiple inverters must not share the same photovoltaic array, as this may cause irreversible damage to the inverters. Each inverter needs to be connected to two photovoltaic input terminals, with each terminal connected to a separate photovoltaic array.

4. Operation
4.1 Power ON/OFF
Once the unit is properly installed and the batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
Steps to Start Up:
Connect the battery (voltage needs to be beyond 46V) or AC (AC input range depends on the output mode). Then, you can start up the inverter.
- Mains Power On: Connect to normal AC power, press the switch. The system will automatically turn on. If AC output power priority is set, after a delay, the panel will display "AC mode" indicating successful startup.
- Battery Boot: Connect to the battery, press the power-on button. The system will automatically turn on. After a delay, the panel will display "battery mode" indicating successful startup.
Shutdown Steps:
When the system is in battery mode or AC mode output, press the switch again to turn off the system.
4.2 Operation and Display Panel
The front panel of the inverter features an LCD display, three indicators, and four function keys to show operating status and input/output power information.
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
| LED Indicator | Color | Status | Message |
|---|---|---|---|
| AC/INV | Green | Solid On Flashing | Output is powered by utility in Line mode. Output is powered by battery or PV in battery mode. |
| CHG | Yellow | Solid On Flashing | Battery is fully charged. Battery is charging. |
| FAULT | Red | Solid On Flashing | Fault occurs in the inverter. Warning condition occurs in the inverter. |
4.3 LCD Display Icons
The LCD display provides detailed information about the inverter's status. Information is cycled by pressing the "UP" or "DOWN" keys.
- Input Source Information: Icons indicate AC input, 1st PV panel input, and 2nd PV panel input.
- Digital Display Information: Shows input voltage, input frequency, battery voltage, PV1 voltage, PV2 voltage, charger current, output voltage, output frequency, load percentage, load in VA, load in Watt, PV1 charger power, PV2 charger power, DC discharging current.
- Middle Display: Indicates setting programs, warning, and fault codes.
- Battery Information: Displays battery level (0-24%, 25-49%, 50-74%, 75-100%) and charging status.
- Load Information: Indicates overload status and load level (0-25%, 25-50%, 50-75%, 75-100%).
- Mode Operation Information: Icons show if the unit is connected to mains, PV1, solar charger is working, or DC/AC inverter circuit is working.
- Mute Operation: Indicates if the unit alarm is disabled.
4.4 LCD Settings
To enter the setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to select programs, and "ENTER" to confirm or "ESC" to exit.
Key configurable settings include:
- Output Source Priority: Solar first, SBU priority (Solar -> Battery -> Utility), or Utility first.
- Maximum Charging Current: Configures total charging current for solar and utility chargers (10A to max, 10A increments).
- AC Input Voltage Range: Configurable for appliances (90-280VAC) or UPS (170-280VAC).
- Battery Type: AGM, Flooded, User-Defined, LIA-protocol compatible, Pylontech, Techfine, Growatt.
- Auto Restart: For overload or over temperature conditions.
- ECO Function: Temporarily stops operation when load is low in battery mode.
- Output Frequency: 50Hz/60Hz.
- Output Voltage: 220V/230V/240V.
- Solar Energy Feed to Grid: Enable/Disable.
- Time Settings: Minute, Hour, Day, Month, Year.
- Dual Output Settings: Functional voltage point, functional SOC point, battery voltage receiver, battery SOC receiver, discharge time.
4.5 Communication Interfaces
The inverter is equipped with multiple communication interfaces for enhanced system integration and monitoring.

- RS232: For communication with host computers or monitoring devices, enabling remote parameter configuration and data retrieval. Use a dedicated RJ45-to-DB9 communication cable (purchased separately).
- BMS/RS485: Integrated port for communication with lithium battery systems for battery data acquisition and charge/discharge management.
- Parallel Connection: Interface for connecting multiple inverters in parallel.
4.6 Dry Contact Signal
A dry contact (3A/250VAC) is available on the rear panel. It can be used to deliver a signal to an external device when the battery voltage reaches a warning level. This supports remote control of external devices and is widely used in scenarios such as alarms, temperature control, and generator linkage (supports generators with remote start/stop functionality).
| Unit Status | Condition | NC & C | |
|---|---|---|---|
| Power Off | Unit is off and no output is powered. | Close | |
| Power On | Output is powered from battery or solar (Normal mode) | Battery voltage < Low DC warning voltage | Open |
| Battery voltage > Float charging voltage | Close | ||
| Output is powered from battery or solar (Solar first mode) | Battery voltage < Solar to AC voltage | Open | |
| Battery voltage > AC to DC voltage | Close |

5. Maintenance
5.1 Battery Equalization
The equalization function in the charge controller reverses the buildup of negative chemical effects like stratification (where acid concentration is greater at the bottom of the battery). Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, reduces the overall capacity of the battery. Therefore, it is recommended to equalize the battery periodically.
How to Apply Equalization Function:
You must enable the battery equalization function in monitoring LCD setting program 30 first. Then, you can apply this function by either:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize:
When the set equalization interval (battery equalization cycle) is reached, or equalization is activated immediately, the controller will enter the Equalize stage.

Equalize Charging Time and Timeout:
In the Equalize stage, the controller supplies power to charge the battery until the battery voltage reaches the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the equalization voltage. The battery remains in the Equalize stage until the set battery equalized time is reached.
If the battery equalized time expires and the battery voltage does not rise to the equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the equalization voltage. If the battery voltage is still lower than the equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
6. Troubleshooting
6.1 Faults Descriptions
When a fault occurs, the inverter enters fault mode, the red LED light is continuously on, and the LCD displays a fault code. Refer to the table below for specific fault events and their corresponding actions.
| Fault Code | Fault Event | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | Replace the fan. |
| 02 | Over temperature or NTC is not connected well. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| 03 | Battery voltage is too high. | Check if spec and quantity of batteries meet requirements. |
| 04 | Battery voltage is too low. | Re-charge battery. Replace battery. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Check if wiring is connected well and remove abnormal load. |
| 06/58 | Output abnormal (Inverter voltage below 190Vac or is higher than 260Vac) | Reduce the connected load. Return to repair center. |
| 07 | Overload time out. | Reduce the connected load by switching off some equipment. |
| 08/09/53/57 | Bus voltage is too high / Bus soft start failed / Inverter soft start failed / Current sensor failed. | Return to repair center. |
| 51 | Over currents or surge. | Restart the unit, if the error happens again, please return to repair center. |
| 59 | PV input voltage is beyond these specification. | Reduce the number of PV modules in series. |
| 71 | Firmware version inconsistent. | Return to repair center. |
| 72 | Current sharing fault. | Check if wiring is connected well and remove abnormal load. |
| 80 | CAN fault. | Return to repair center. |
| 81 | Host loss. | Return to repair center. |
| 82 | Synchronization loss. | Return to repair center. |
| 83 | Battery voltage detected different. | Return to repair center. |
| 84 | AC input voltage and frequency detected different. | Return to repair center. |
| 85 | AC output current unbalance. | Return to repair center. |
| 86 | AC output mode setting is different. | Return to repair center. |
6.2 Warning Descriptions
When a warning occurs, the red LED flashes, and the LCD displays an alarm code. The inverter does not enter failure mode but indicates a condition that needs attention.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 02 | Over temperature. | None |
| 03 | Battery is over-charged. | Beep once every second |
| 04 | Low battery. | Beep once every second |
| 07 | Overload. | Beep once every 0.5 second |
| 10 | Output power derating. | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| 16 | High AC input (>280VAC) during BUS soft start. | None |
| E9 | Battery equalization. | None |
| bP | Battery is not connected. | None |
6.3 Code Reference
Related information codes may be displayed on the LCD screen to provide additional operational details.
| Code | Description |
|---|---|
| 60 | If battery status is not allowed to charge and discharge after communication between inverter and battery is successful, code 60 will show to stop charging and discharging battery. |
| 61 | Communication lost. After battery is connected, communication signal is not detected for 1 minute, buzzer will beep. Communication lost occurs after inverter and battery are connected successfully, buzzer beeps immediately. |
| 69 | If battery status is not allowed to charge after communication between inverter and battery is successful, code 69 will show to stop charging battery. |
| 70 | If battery status must charge after communication between inverter and battery is successful, code 70 will show to charge battery. |
| 71 | If battery status is not allowed to discharge after communication between inverter and battery is successful, code 71 will show to stop discharge battery. |
7. Specifications
The following tables provide detailed technical specifications for the PowMr Hybrid Solar Inverters (POW-HVM6.2KP and POW-HVM11KP models).
| Parameter | POW-HVM6.2KP | POW-HVM11KP |
|---|---|---|
| AC Input | ||
| Input Sources | L+N+PE | |
| Rated Input Voltage | 220/230/240VAC | |
| Voltage Range | 90-280VAC±3V (APL Mode); 170-280VAC±3V (UPS Mode) | |
| Frequency | 50Hz/60Hz (Auto Adaptive) | |
| Inverter Output | ||
| Rated Power (Battery Inverter) | 6200W | 11000W |
| Rated Power (Photovoltaic Inverter) | 6500W | 12000W |
| Output Voltage | 220/230/240VAC±5% | |
| Output Frequency | 50Hz/60Hz±0.1% | |
| Waveform | Pure Sine Wave | |
| Transfer Time (Adjustable) | Computers (UPS Mode) 10ms, Appliance (APL Mode) 20ms | |
| Peak Power | 12400VA | 22000VA |
| Overload Capacity | Battery mode: 11s@105%~150%Load; 2s@150%~200%Load; 400ms@>200%Load | |
| Grid-Connected Operation | ||
| Output Voltage | 220/230/240VAC±5% | |
| Feed Into the Grid Voltage Range | 170-265VAC | |
| Feed Into the Grid Frequency Range | 49-51±1Hz / 59-61±1Hz | |
| Nominal Output Current | 27A | 47.8A |
| Power Factor Range | >0.99 | |
| Maximum Conversion Efficiency (DC/AC) | 98% | |
| Battery | ||
| Battery Voltage | 48Vdc | |
| Constant Charging Voltage (Adjustable) | 56.4Vdc | |
| Float Charging Voltage (Adjustable) | 54Vdc | |
| PV Input | ||
| PV Charging Mode | MPPT | Dual MPPT |
| MAX. PV Input Power | 8500W | 7500W/7500W |
| MPPT Tracking Range | 60~500Vdc | 90~500Vdc |
| Operating Voltage | 360~430V | |
| MAX. PV Input Voltage | 500Vdc | |
| PV Max Input Current | 27A | 27A/27A |
| MAX. PV Charging Current | 120A | 150A |
| MAX. AC Charging Current | 100A | 150A |
| MAX. Charging Current | 120A | 150A |
| Display & Interface | ||
| LCD Interface | CAN display running mode/load/input/output, etc. | |
| RS232 | Baud Rate 2400 | |
| Extend the Socket Communication Interface | Lithium Battery BMS Communication Card, WiFi Card, Dry Contact | |
| Parallel Machine Interface | Parallel Machine (network) function | |
| General Specifications | ||
| Operating Temperature | -10°C~50°C | |
| Humidity | 20%~95% (Non-condensing) | |
| Storage Temperature | -15°C~60°C | |
| Altitude | Not Over 1000m, Derating over 1000m, Max 4000m, Refer to IEC62040 | |
| Noise | ≤50db | |
| Standards and Certification | EN-IEC 60335-1, EN IEC 60335-2-29, IEC 62109-1 | |
8. User Tips
- Voltage Compatibility: The inverter is designed for 220V/230V/240V AC output. It is not compatible with 110V systems. Please ensure your electrical system matches these specifications.
- Parallel Operation: When operating multiple inverters in parallel, ensure all battery cables are of the same length to prevent voltage differences that could affect performance.
- Battery Type Selection: Carefully select the correct battery type in the LCD settings (AGM, Flooded, User-Defined, Lithium types) to ensure proper charging and discharge management.
- Air Conditioner Connection: If connecting an air conditioner, verify it has a time-delay function to prevent damage from rapid power cycling.
- Monitoring: Utilize the RS232 or WiFi communication options to monitor your system's performance and adjust settings remotely via a host computer or mobile app.
9. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact the manufacturer directly:
- Company: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Telephone/Fax: +86 755-28219903
- Email: support@powmr.com
- Website: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China