MOES PTH-24E 4-in-1 Carbon Monoxide and Combustible Gas Detector

Instruction Manual

1. Introduction

This MOES PTH-24E device is a versatile 4-in-1 detector designed to monitor carbon monoxide (CO) and combustible gases, along with ambient temperature and humidity. Its plug-in design ensures easy installation and immediate operation, providing continuous protection for your home or premises.

Package Contents:

  • PTH-24E Detector × 1
  • Instruction Manual × 1
  • Replaceable Plug × 1 (EU/US/UK depending on region)
Front view of the detector displaying CO, Gas, Temperature, and Humidity, with a breakdown of its functions and sensors.
Front view of the detector displaying CO, Gas, Temperature, and Humidity, with a breakdown of its functions and sensors.

2. Important Safety Information

Please read this manual carefully before installation and use. Keep it for future reference.

  • This device is designed for continuous monitoring of CO and combustible gases. It is not a substitute for proper ventilation and maintenance of fuel-burning appliances.
  • Do not paint the detector. Paint can clog the sensor openings and prevent the unit from functioning properly.
  • Do not block the ventilation openings on the device.
  • Test the alarm regularly as described in the 'Operation' section.
  • In case of an alarm, immediately follow the instructions provided in the 'Alarm Response' section.
Infographic illustrating the hazards of carbon monoxide and combustible gas, including symptoms and risks.
Understanding the hazards of Carbon Monoxide (CO) and Combustible Gas. CO poisoning symptoms include palpitations, headache, coma, and organ damage. Gas leaks can lead to suffocation and dizziness.

3. Setup

3.1 Plug & Play Installation

The MOES PTH-24E detector is designed for simple plug-and-play installation. No complex wiring or setup is required.

  1. Select an appropriate wall outlet for installation. Ensure it is not obstructed and is within a suitable monitoring area (e.g., near fuel-burning appliances, living areas).
  2. Insert the detector directly into the wall outlet. The device will power on automatically.
  3. The display will illuminate, and the device will begin its self-test and initialization process.
Image demonstrating the 'Plug & Play' feature, showing the detector being plugged into a wall outlet.
Simply plug the detector into a standard wall outlet for immediate operation.

3.2 Replacing the Plug

The detector features a replaceable plug to accommodate various socket types.

  1. To remove the current plug, locate the 'Disassembling Button' on the back of the unit.
  2. Press the button and twist the plug (Right Twist to OPEN, Turn Left to LOCK) to detach it.
  3. Align the desired plug type with the connector on the detector and twist it until it locks securely into place.
Detailed view of the product's front and back, labeling components like the display elements, plug, disassembly button, and ventilation.
Detailed view of the product's front and back, showing the replaceable plug mechanism and ventilation.

4. Operation

4.1 Display Overview

The color LCD display provides real-time information:

  • CO PPM: Carbon Monoxide concentration in parts per million.
  • GAS S1: Combustible gas level (indicated by a bar graph, Lv1-4).
  • Temperature: Current ambient temperature (in °C or °F).
  • Humidity: Current relative humidity (in %).
  • Alert Icon: Indicates alarm status.
  • Sound Icon: Indicates if the audible alarm is enabled or muted.

4.2 Key Functions

The device features intuitive buttons for various controls:

Diagram detailing the key functions of the detector's buttons, including temperature unit switching, self-test, brightness adjustment, screen flip, and sound control.
Key functions of the detector's control buttons.
  • Top Button (U icon):
      - Long Press: Switches the temperature unit between Celsius (°C) and Fahrenheit (°F).
  • Middle Button (Light icon):
      - Short Press: Initiates a self-test of the device.
      - Short Press (repeatedly): Adjusts screen brightness through three levels (100%, 50%, 0% - breathing light off).
      - Long Press: Flips the screen display 180 degrees for inverted viewing.
  • Bottom Button (Bell icon):
      - Short Press: Toggles the audible alarm sound on/off (mute/unmute).
Illustration showing the screen inversion feature of the detector.
The screen can be inverted 180 degrees for optimal viewing.

4.3 Demonstration Video

Watch this video for a visual guide on the detector's features and operation:

A video demonstrating the detector's alarm function, plug-and-play setup, brightness adjustment, screen rotation, and real-time gas detection.

5. Alarm System

The detector provides four levels of visual and audible alarms to indicate varying concentrations of CO and combustible gases. The audible alarm is greater than 85dB.

Diagram illustrating the four levels of visual and audible alarms (Safety, Attention, Warning, Danger) with corresponding CO PPM and Gas LFL ranges.
Four distinct levels of visual and audible alarms for CO and combustible gas detection.
Alarm Levels and Indicators
LevelCO ConcentrationCombustible Gas (LEL)Visual IndicatorAudible Alarm
Safety0-50 PPM< 5% LFL (Lv1)Green indicator lightNone
Attention51-100 PPM5% < Lv2 < 8% LFLYellow indicator light flashes slowlyAudible alarm (slow)
Warning101-150 PPM8% < Lv3 < 15% LFLOrange indicator light flashes fastAudible alarm (fast)
Danger150-999 PPM≥ 15% LFL (Lv4)Red indicator light flashes fastFast audible alarm

5.1 Alarm Response

If the alarm sounds:

  1. Immediately move to fresh air outdoors or open all doors and windows to ventilate the area.
  2. Turn off all fuel-burning appliances.
  3. Call your gas supplier or fire department.
  4. Do not re-enter the premises until the alarm has stopped and the area has been deemed safe by professionals.

6. Maintenance

6.1 Cleaning

  • Clean the exterior of the detector regularly with a soft, damp cloth.
  • Do not use cleaning agents, solvents, or abrasive materials, as these can damage the sensors or casing.
  • Ensure the ventilation openings are free from dust and debris.

6.2 Testing

Perform a self-test weekly by short-pressing the middle (light icon) button to ensure the alarm and display are functioning correctly.

7. Troubleshooting

If you experience issues with your detector, please refer to the full user manual (PDF) for detailed troubleshooting steps or contact customer support.

Common Issues:

  • No display/power: Ensure the detector is securely plugged into a live outlet.
  • False alarms: Ensure the detector is not placed near sources of high humidity, steam, or strong chemical fumes.
  • Alarm not sounding during self-test: Contact customer support.

8. Specifications

FeatureDetail
Model NumberPTH-24E
Gas Type DetectedCarbon Monoxide (CO), Combustible Gas
CO Detection Range0~999 PPM (±10%)
CO Sound Alarm Range (Default)51 PPM
Combustible Gas Detection RangeGAS Lv1-4 (Lv4 = 15% LEL)
GAS Sound Alarm RangeGAS Lv2 ≥ 5% LEL
Temperature Detection Range-10°C~50°C (±1.5°C) / 14°F~122°F (±2.7°F)
Humidity Detection Range0%~95% RH (±5%)
Input Voltage100-220V 50/60Hz
Plug TypeReplaceable (EU, US, UK options available)
Screen2.0' 320*240 IPS Color LCD
Shell MaterialFlame Retardant ABS Plastic
Work Temperature-10°C~50°C / 14°F~122°F
Alarm Sound Level>85dbs
Product Size (with plug)105mm (H) x 55mm (D) x 52mm (W)
CertificationsUL, CE
Battery IncludedNo
Is Smart DeviceNo
Diagram showing the dimensions of the detector.
Dimensions of the MOES PTH-24E detector.

9. Warranty and Support

9.1 Warranty Information

This product comes with a manufacturer's warranty. Please refer to the warranty card included in your package or the official MOES website for detailed terms and conditions regarding warranty coverage and duration.

9.2 Customer Support

For technical assistance, troubleshooting, or any inquiries regarding your MOES PTH-24E detector, please contact MOES customer support through their official channels. Contact information can typically be found on the product packaging or the official MOES website.

© 2024 MOES. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.