1. General Information
The Myoslim Desktop RF Body Shaping Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
Advanced HI-EMT Technology
The EMS Body Sculpt series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.
Touch-Controlled Display
The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.
Real-time Monitoring and Guidance
Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.
Upgradeability
As your therapeutic needs evolve, you may wish to upgrade your equipment later on. The EMS Body Sculpt series offers flexible upgrade options to meet your future treatment requirements.
1.1 Indications for Use
EMS Body Sculpt is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
- Strengthening, Toning and Firming of buttocks, thighs and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.5 Contraindications
Do not use the device if any of the following conditions apply:
- Wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patient.
- Patients with infectious diseases.
- Pregnant women, lactating women, menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
2. Safety Precautions and Warnings
Observe the following precautions before using the device:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest intensity level and gradually increase it according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Consume food at least one hour after the operation.
3. Setup and Device Installation
3.1 Front and Rear Panel of the Main Unit
The main unit features a display screen, EMS handles, a roller weight loss handle, and an On/OFF button on the front. The rear panel includes connections for the roller weight loss handle plugs, magnetic thin handle plug, and power plug.
Note: The handle can only be used by the original machine and cannot be used interchangeably.
3.2 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle (EMS) | 2 | ![]() |
| Handle (Roller) | 2 | ![]() |
|
| Cushion (optional accessories) | 1 | ![]() |
|
| 3 | Belts (8*80CM, 8*90CM, 8*100CM) | 3 | ![]() |
| 4 | Power cable | 1 | ![]() |
| 5 | Electronic manual | 1 copy |
3.3 Device Installation Steps
-
Install the handle bracket: Use a screwdriver to install the handle brackets on both sides of the main unit. Ensure they are securely fastened.
Figure 3: Handle Bracket Installation -
Apply handle film: Stick the protective film to the working part of the handles.
Figure 4: Handle Film Application -
Install the handles: Align the holes and fasten the clips to secure the handles. Lock the key ring to complete the installation.
Figure 5: Handle Installation -
Connect power: Connect one end of the power cord to the machine and the other end to a socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.
Figure 6: Power Connection - Press the back switch: Move the manual switch on the rear panel to the "o" position (Power on).
- Press the front switch: Single-click the front button to power on. Long press to power off.
4. Operating Instructions
4.1 Handle Exchange
Warning: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
4.2 Device Start-up/Shut-down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
4.3 Navigation Controls and Therapy Settings
The pre-treatment regimen can be modified via on-screen controls. The treatment interface displays various items and functions:
The display allows selection between EMS and Roller functions, and adjustment of time, energy, and rotation speed. You can also select pre-set patterns.
Setting Therapy by Controls (EMS Mode)
In EMS mode, you can adjust the time and energy levels. The interface shows two patterns, Pattern 1 and Pattern 2, each with adjustable parameters for frequency (F1, F2, F3) and energy.
Note: Adjust the corresponding intensity according to different customer needs to start the operation. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.
Setting Therapy by Controls (Roller Mode)
In Roller mode, you can select between a 'Big wheel' and 'Small wheel' and adjust the rotation speed (FWD/REV) and time.
4.4 Unit Settings
The device allows for various settings adjustments:
- Language Settings: Select your preferred language from the available options.
- Sound Adjustment: Adjust the device's sound volume.
- Brightness Adjustment: Control the display screen's brightness.
- Set Date/Time: Configure the current date and time.
- System Adjustment: Access system-level settings.
- Technician Access: A password-protected section for technical adjustments.
4.5 Preparing for Therapy
- Communicate with patients regarding the procedure.
- Ensure the patient is in good health.
- Ensure the patient is well-hydrated.
- The patient should wear appropriate clothing.
- Avoid eating large quantities before the session.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol before the session.
4.6 Placing the Handle
The EMS handles can be placed on various body parts for treatment. Ensure proper contact with the skin.
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
5. Maintenance
5.1 Daily Inspection
Regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
5.2 Cleaning
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off.
5.3 Replacing the Fuse
When replacing the fuse, to prevent electric shock, please turn off the power and unplug the power plug. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.
5.4 Cleaning of the Surface of the Device
The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.
5.5 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
5.6 Storage
The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, the relative humidity should not be greater than 93%, and it is not allowed to be placed near harmful gases, flammable, explosive substances, and corrosive gases.
6. Troubleshooting
Refer to the table below for common faults and their solutions:
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection | Reseat the handle |
7. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Function | Electromagnetic Sculpting Body Slimming Muscle Build, Fat Removal, weight loss |
| Feature | Hiemt R/F EMSzero body contouring machine |
| Treatment area | Body arm waist abdomen buttocks upper legs |
| Advantage | Non-invasive, EMSzero muscle stimulation Body Sculpt machine |
| Technology | EMS/HIEMT+RF |
| Functions | skin tight, butt lift, muscle build, muscle stimulation |
| Color | Black /white |
| Power Supply | Direct Current |
| Voltage | 50-1000V AC |
| Material | ABS |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Name | E-02 |
| Input power supply | AC110V-220V 50/60Hz |
| Output maximum power | 0-6500W |
| Frequency | 5-200HZ |
| Screen size | 8.0 inches |
| Machine color | White |
| Package Length | 53 cm |
| Package Width | 53 cm |
| Package Height | 63 cm |
| Package Weight | 55.0 kg |
7.1 Electromagnetic Compatibility (EMC) Test
The device has undergone Radiated Electromagnetic Field Immunity Test according to IEC 61000-4-3:2020 standards.
| Parameter | Value |
|---|---|
| Port | Enclosure |
| Basic Standard | IEC 61000-4-3:2020 |
| Test Level | 30V/m with 80% AM, 1kHz Modulation |
| Standard require | A |
| Tester | Sam Liu |
| Temperature | 25°C |
| Humidity | 54% |
Test Equipment
| Description | Manufacturer | Model | Identifier | Cal. Date | Cal. Due |
|---|---|---|---|---|---|
| Signal Generator | IFA | 2023B | N/A | 15/03/2022 | 14/03/2023 |
| Power Amplifier | AR | 150W1000 | N/A | 15/03/2022 | 14/03/2023 |
| Power Antenna | AR | 25S1G4A | N/A | 15/03/2022 | 14/03/2023 |
Block Diagram of Test Setup
8. Warranty and Support
8.1 Warranty Card Information
The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates may incur charges. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping out cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year.
Free warranty service is not provided for the following user's failures caused by personal reasons:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
8.2 Maintenance Record Sheet
| Product Name | Purchase Date |
|---|---|
| Dealer Name | Telephone |
|---|---|
| Dealership Address |
|---|
| Customer Name | Telephone |
|---|---|
| Customer Address |
|---|
| Maintenance Date | Cause of Issue | Maintenance Content |
|---|---|---|
8.3 Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
After-sales Service Provided: Online support, Video technical support, Maintenance and repair service.
9. User Tips
- For optimal results, maintain a consistent treatment schedule and combine with a healthy diet and regular exercise.
- Always start with the lowest intensity setting and gradually increase it to a comfortable level to avoid discomfort or injury.
- Ensure the skin is clean and dry before each session to maximize contact and effectiveness of the handles.
- Hydrate well before and after sessions to support the body's metabolic processes.
- If you experience any unusual pain or discomfort, stop the treatment immediately and consult a healthcare professional.
10. Frequently Asked Questions (FAQ)
- Q: How often should I use the machine?
- A: The frequency of use depends on individual goals and tolerance. It is generally recommended to follow the guidelines provided in the operating instructions or consult with a professional.
- Q: Can I use the machine on my face?
- A: The product description mentions a 'Face & Neck Roller' material, but the primary treatment areas listed are body parts (waist, abdomen, buttocks, arms, thighs, calves). Please refer to the specific handle instructions for appropriate usage areas.
- Q: What is the difference between EMS and Roller modes?
- A: EMS (Electrical Muscle Stimulation) mode focuses on muscle contraction and fat breakdown through electromagnetic waves. Roller mode uses mechanical rolling and pushing to promote blood circulation and reduce subcutaneous fat. Both can be used for body shaping and weight loss.
- Q: Is the treatment painful?
- A: The intensity should be adjusted to a comfortable level. Some muscle soreness or a warm sensation may be experienced, especially for first-time users. If you feel sharp pain, reduce the intensity or stop the treatment.