Gaqqee SK120S

Contents

SK120S Digital Voltage Step-Up/Step-Down Module Instruction Manual

Adjustable Regulated Power Supply Module with Solar Charging Capability

Product Overview

The Gaqqee SK120S is a versatile digital DC buck-boost power supply module designed for precise voltage and current regulation. It features an intuitive 1.8-inch full-view high-brightness true color LCD, customizable color schemes, and 4-way rotation support for optimal viewing. This module integrates MPPT intelligent charging technology, making it suitable for solar charging applications, and offers multi-layer safety protections for secure and stable operation.

SK120S Digital Voltage Step-Up/Step-Down Module with display showing 12.00V, 5.000A, 60.00W, and various icons.

Figure 1: SK120S Module with key features highlighted.

Safety Information

WARNING:

  • This product does not have output reverse connection protection. Connecting battery terminals incorrectly may damage the device.
  • Battery charging requires specialized knowledge; non-professionals should not attempt direct charging to prevent fire or explosion.
  • This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Package Contents

  • SK120S Module x1

Setup

1. Physical Connections

Connect the input voltage source to the VIN+ and VIN- terminals, and the load or battery to the OUT+ and OUT- terminals. Ensure correct polarity to avoid damage.

Close-up of VIN+ VIN- OUT+ OUT- terminals on the SK120S module.

Figure 2: Input and Output Terminals.

For solar charging, connect the solar panel to the input terminals. An external NTC temperature probe can be connected to the designated interface to support over-temperature protection for battery charging. This will automatically stop charging if the battery temperature exceeds safe limits.

Diagram showing SK120S module connected to a solar panel and an external NTC temperature probe for MPPT solar charging.

Figure 3: MPPT Solar Charging Setup with External Temperature Probe.

2. Remote Control Module (Optional)

The module supports control via an infrared or 433M wireless remote control module. Connect the remote control receiver module to the appropriate port on the SK120S for convenient operation.

SK120S module connected to an infrared remote control module and a 433M wireless remote control module.

Figure 4: Remote Control Module Connections.

3. Network Control (Optional)

For remote monitoring and control, the module can be connected to a network via a WiFi module. This allows for real-time communication, email notifications, and cloud record keeping through a PC host computer or mobile app (Android/iOS).

Diagram showing the SK120S module connected to a WiFi module, router, and controlled via PC and mobile app.

Figure 5: Network Control Setup.

Operating Instructions

1. Button Functions

The SK120S module features 5 buttons and an encoder for intuitive control:

Diagram illustrating the functions of each button and the encoder on the SK120S module.

Figure 6: Universal Button Functions.

  • V-SET Button:
    • Short Press: Set output voltage (CV mode).
    • Long Press: Quickly recall data set M1.
  • SW Button:
    • Short Press: Enter quick settings.
    • Long Press: Enable four-way screen rotation.
  • I-SET Button:
    • Short Press: Set output current (CC mode).
    • Long Press: Enter or exit the data group settings UI.
  • Encoder Button:
    • Short Press: Shift cursor/selection.
    • Long Press: Lock the button.
  • ON/OFF Button:
    • Short Press: Turn power output on/off.
    • Long Press: Shut down the device.

2. Display and Navigation

The 1.8-inch LCD provides a clear view of parameters. Long pressing the SW button on the main UI allows for 360° screen rotation, enabling comfortable viewing from any angle.

Four views of the SK120S display rotated at 90-degree intervals, demonstrating 360-degree rotation capability.

Figure 7: 360° Display Rotation.

3. Basic Operation Demonstration

Watch this video for a quick demonstration of setting voltage, current, resetting parameters, and using the remote control.

Play video
Watch video online

Video 1: SK120S Basic Operation and Remote Control Demo.

  • Setting Voltage/Current: Use the V-SET and I-SET buttons, then adjust with the encoder.
  • Resetting Data: Navigate to the appropriate interface and use the encoder to reset capacity, energy, or runtime.
  • Data Set Parameters: Long press I-SET to enter the data group settings UI.
  • System Parameters: Navigate through the menu using the encoder.
  • Remote Control Operation: Use the remote to power on/off, adjust settings, and quickly recall data sets (Shift + Number keys).

Maintenance

To ensure the longevity and optimal performance of your SK120S module, follow these general maintenance guidelines:

  • Keep the module clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Avoid exposing the module to extreme temperatures, humidity, or direct sunlight.
  • Ensure proper ventilation around the module during operation to prevent overheating.
  • Regularly check all connections for tightness and ensure no wires are frayed or damaged.
  • Store the module in a dry, cool place when not in use.

Troubleshooting

The SK120S module is equipped with multi-layer safety protections to ensure stable operation. If you encounter issues, check the display for any error indicators related to these protections:

Diagram showing various protection features: LVP (under-voltage), OVP (over-voltage), OCP (over-current), OPP (over-power), OTP (over-temp), OHP (over-time out), OAH (over-capacity), OWH (over-energy).

Figure 8: Multi-Layer Safety Protections.

Protection TypeDescriptionPossible Cause / Action
LVPUnder-voltage protectionInput voltage too low. Check input power source.
OVPOver-voltage protectionOutput voltage exceeds set limit. Adjust output voltage or OVP setting.
OCPOver-current protectionOutput current exceeds set limit. Reduce load or adjust OCP setting.
OPPOver-power protectionOutput power exceeds set limit. Reduce load or adjust OPP setting.
OTPOver-temperature protectionInternal temperature too high. Ensure proper ventilation.
OHPOver-time out protectionOperation time exceeds set limit. Reset timer or adjust OHP setting.
OAHOver-capacity protectionOutput capacity exceeds set limit. Reset capacity counter or adjust OAH setting.
OWHOver-energy protectionOutput energy exceeds set limit. Reset energy counter or adjust OWH setting.

If the module does not power on or respond, check all power connections and ensure the input voltage is within the specified range.

Specifications

ParameterValue
Product NameDigital DC Step-Down Power Supply
Input Voltage6.000-36.00V
Output Current0-7.000A
Output Voltage0~40.00V
Output Power120W
Voltage Resolution0.01V
Stored Data Sets10 sets
Display Size1.8-inch LCD
Conversion EfficiencyApprox. 88%
Voltage Accuracy±0.5% + 1 digit
Current Accuracy±0.5% + 3 digits
Current Resolution0.001A
Number of Buttons5
BuzzerYes
Soft StartYes
Typical Output Ripplevpp-150mV
MPPT FunctionSupports MPPT solar charging
Package Dimensions (L x W x H)12 cm x 8 cm x 5 cm
Package Weight0.138 kg

User Tips

  • Always be mindful of the maximum permissible current (7A) to prevent damage to the module.
  • The bright and clear LCD screen makes settings easy to navigate.
  • Utilize the intelligent features, such as MPPT for solar charging, to optimize performance.
  • For detailed parameter adjustments, refer to the data group settings UI.
  • Consider using the remote control for convenience, especially when the module is in a hard-to-reach location.

Warranty and Support

For warranty information and technical support, please contact the seller or refer to the official product page where you purchased the item.

An additional user manual in PDF format is available for download: User Manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.