YIHUA 948D-IV

Contents

YIHUA 948D-IV Multi-functional Precision Soldering Station

Model: 948D-IV | 5-in-1 & ESD-Safe

1. Introduction

This manual provides detailed instructions for the safe and effective use of your YIHUA 948D-IV Multi-functional Precision Soldering Station. Please read it carefully before operation and keep it for future reference.

YIHUA 948D-IV 5-in-1 Multi-functional Precision Soldering Station with all its components laid out.

Figure 1: Overview of the YIHUA 948D-IV 5-in-1 Precision Rework Station and its included tools.

Video 1: Product demonstration showing the setup and various functions of the YIHUA 948D-IV station.

I. Applications

  1. Integrated with precision hot air pencil rework station, hot tweezer soldering station, micro soldering station, desoldering station and suction pen, this station is suitable for desoldering and soldering applications of various through-hole and SMD components such as SOIC, CHIP, QFP, PLCC, BGA packages and more. The product is also suitable to be used on small components on the mobile phone circuit boards, in-line sockets, transformer, LCD screens, IC chips, in-line pins and more.
  2. The unit's applications include heat shrinking, drying, paint removal, glue removal, defrosting, pre-heating, glue soldering, and more.

2. Important Safety Guidelines

CAUTION!!! WARNING!!!

Strictly follow the basic safety guidelines and precautions when using the product.

  • To provide continued protection against risk of electric shock, connect to properly grounded outlets only.
  • Do not immerse in water.
  • Hot Surface. Avoid Contact.
  • Shock Hazard. To provide continued protection against electric shock disconnect from the power supply when not in use.
  • Place the hot air gun and soldering iron on their respective stand when not in use.
  • HOUSEHOLD AND INDOOR USE ONLY.
  • To prevent electric shock, unplug before replace the fuse and other service.
  • Replace only with same type and rating of fuse.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • The soldering iron and desoldering iron is only to be used with the power supply unit provided with the appliance.
  • If the SUPPLY CORD is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Any servicing should be performed by an authorized service representative AND that the product has no user serviceable parts.
  • To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. Store indoors. Read instruction manual before using.
  • A fire may result if the appliance is not used with care, therefore:
    • be careful when using the appliance in places where there are combustible materials; do not apply to the same place for a long time;
    • do not use in presence of an explosive atmosphere be aware that heat may be conducted to combustible materials that are out of sight,
    • place the appliance on its stand after use and allow it to cool down before storage do not leave the appliance unattended when it is switched on.
  • WARNING: Extreme care should be taken when stripping paint. The peelings, residue and vapors of paint may contain lead, which is poisonous. Any pre-1977 paint may contain lead and paint applied to homes prior to 1950 is likely to contain lead. Once deposited on surfaces, hand to mouth contact can result in the ingestion of lead. Exposure to even low levels of lead can cause irreversible brain and nervous system damage; young and unborn children are particularly vulnerable.
  • Before beginning any paint removal process you should determine whether the paint you are removing contains lead. This can be done by your local health department or by a professional who uses a paint analyzer to check the lead content of the paint to be removed.
  • LEAD-BASED PAINT SHOULD ONLY BE REMOVED BY A PROFESSIONAL AND SHOULD NOT BE REMOVED USING A HEAT GUN.
  • Persons removing paint should follow these guidelines:
    • Move the work piece outdoors. If this is not possible, keep the work area well ventilated. Open the windows and put an exhaust fan in one of them. Be sure the fan is moving the air from inside to outside.
    • Remove or cover any carpets, rugs, furniture, clothing, cooking utensils and air ducts.
    • Place drop cloths in the work area to catch any paint chips or peelings. Wear protective clothing such as extra work shirts, overalls and hats.
    • Work in one room at a time. Furnishings should be removed or placed in the center of the room and covered. Work areas should be sealed off from the rest of the dwelling by sealing doorways with drop cloths.
    • Children, pregnant or potentially pregnant women and nursing mothers should not be present in the work area until the work is done and all clean up is complete.
    • Wear a dust respirator mask or a dual filter (dust and fume) respirator mask which has been approved by the Occupational Safety and Health Administration (OSHA), the National Institute of Safety and Health (NIOSH), or the United States Bureau of Mines. These masks and replaceable filters are readily available at major hardware stores. Be sure the mask fits. Beards and facial hair may keep masks from sealing properly. Change filters often. DISPOSABLE PAPER MASKS ARE NOT ADEQUATE.
    • Use caution when operating the heat gun. Keep the heat gun moving as excessive heat will generate fumes which can be inhaled by the operator.
    • Keep food and drink out of the work area. Wash hands, arms and face and rinse mouth before eating or drinking. Do not smoke or chew gum or tobacco in the work area.
    • Clean up all removed paint and dust by wet mopping the floors. Use a wet cloth to clean all walls, sills and any other surface where paint or dust is clinging, DO NOT SWEEP, DRY DUST OR VACUUM. Use a high phosphate detergent or trisodium phosphate (TSP) to wash and mop areas.
    • At the end of each work session put the paint chips and debris in a double plastic bag, close it with tape or twist ties and dispose of properly.
    • Remove protective clothing and work shoes in the work area to avoid carrying dust into the rest of the dwelling. Wash work clothes separately. Wipe shoes off with a wet rag that is then washed with the work clothes. Wash hair and body thoroughly with soap and water.
  • To ensure personal safety, please turn off the power switch after work is completed; When not in use for an extended period, please unplug the power cord!!!
  • Do not install nozzle when the hot air gun is turned on, the heat pipe and the nozzle must be cooling. Then installed the other nozzle.
  • The soldering iron should only be used for soldering. Do not hit the soldering iron against the work surface to remove flux residues (Can be cleaned by the cleaning device of the product), as doing so may seriously damage the soldering iron.
  • Soldering produces fumes, ensure there is adequate ventilation.
  • After used, remember that cooling the unit, the handle should be placed on the handle holder.
  • Longer detachable power-supply cords are available and may be used if care is exercised in their use.
  • If a long detachable power-supply cord is used: 1) The marked electrical rating of the detachable power-supply cord or extension cord should be at least as great as the electrical rating of the appliance 2) The extension cord should be a grounding type 3-wire cord; 3) The longer cord should be arranged so that it will not drape over the countertop or tabletop where it can be tripped over, snagged, or pulled on unintentionally (especially by children).
  • A short power-supply cord (or short detachable power-supply cord) is provided to reduce the risks resulting from becoming entangled in or tripping over a longer cord.

3. Setup Instructions

1. Before Use

  1. Place the suction pen, desoldering gun, hot air gun and soldering iron onto their respective holder.
  2. Connect the hot air gun, hot tweezer, soldering iron, desoldering gun, vacuum pump and suction pen's vacuum pump.
  3. Secure the cable guide and pull down the cable tie. Insert the cable to the slot of the cable guide and pull up the cable tie. The cable will be securely fastened.
  4. Connect the power cord to an electrical socket and turn ON the master power switch.
Back panel connections of the YIHUA 948D-IV station.

Figure 2: Detailed view of the station's back panel connections for various tools and power.

2. Installing and Changing Heating Element

Attach the heating element to the soldering iron and place the soldering iron tip into the hole. Once in place, apply pressure to secure the heating element (1-1). Slot the soldering iron tip into the V-shaped groove and lift the soldering iron to separate the heating element (1-2).

Diagram showing installation and removal of soldering iron heating element.

Figure 3: Illustration of heating element installation and removal for the soldering iron.

Note: When installing, the heating element must be fully inserted to the handpiece.

CAUTION: Upon the first use of the soldering iron tip, when the iron is just hot enough to melt solder, coat the soldering iron tip and desoldering nozzle with a layer of solder (the use of rosin core solder is recommended), then set the temperature to your desired temperature. This can prevent the soldering iron tips and desoldering nozzle from oxidization.

4. Operating Instructions

III. Operation

Diagram showing the 5-in-1 functions of the YIHUA 948D-IV station.

Figure 4: The YIHUA 948D-IV is a 5-in-1 multi-function professional welding station, including Soldering Tweezer, Hot Air Gun, Soldering Iron, Suction Tin Gun, and Suction Pen.

Hot Air Rework Station

  • Manual Mode: Turn ON the power switch, press the hot air gun switch, then press and hold the stand-by button on the hot air gun handle to start the hot air gun. This is to prevent accidental activation and improve safety.
  • Automatic Mode: Turn ON the power switch, then press the hot air gun switch to start the hot air gun.
  • When the temperature has stabilized, press and hold the hot air rework station's temperature increase and decrease button for approximately 2 seconds and then enter the measured temperature by pressing the hot air rework station's temperature increase or decrease button. Once done entering, press the hot air rework station's temperature increase and decrease button simultaneously to confirm.

Hot Tweezer Soldering Station

  • Press and hold the hot tweezer soldering station's power button for about 1 second. Once the temperature has stabilized, the station is ready for use.
  • When the temperature has stabilized, press and hold the hot tweezer station's temperature increase and decrease button for approximately 2 seconds and then press the temperature decrease button to select Heating Element A or temperature increase button to select Heating Element B. Press the hot tweezer station's temperature increase or decrease button to enter the measured temperature. Once done entering, press the hot tweezer station's temperature increase and decrease button simultaneously to confirm.

Precision Soldering Station

  • Press and hold the Precision Soldering station's power button for about 1 second. Once the temperature has stabilized, the station is ready for use.
  • When the temperature has stabilized, press and hold the Precision Soldering station's temperature increase and decrease button for approximately 2 seconds and then enter the measured temperature by pressing the Precision Soldering station's temperature increase or decrease button. Once done entering, press the temperature increase and decrease button simultaneously to confirm.

Desoldering Station

  • Basic Operations: Pht - "Pht" is an indication that the desoldering station is pre-heating. The vacuum pump will not be activated when this code is active. Press and hold the desoldering station's power button for about one second. When the desoldering gun is pre-heating, the vacuum pump will not be activated; once the pre-heating is complete, the station is ready for use.
  • While desoldering, position the desoldering gun vertically on the solder joint that needs to be desoldered. Once the solder on top/ at the bottom has melted, press the desoldering gun's trigger to desolder the joint.
  • If there is remaining solder residue inside the holes of the circuit board, please apply additional solder and then repeat the desoldering procedure.
  • If the component pin is adhered to the inside of the printed circuit board's hole and the solder cannot be removed. Reapply solder to the joint and then melt the solder using the desoldering nozzle. Gently move the desoldering nozzle back and forth to nudge the component's pin, until it is no longer in contact with the hole. Then, press the desoldering trigger to remove the solder completely.

Suction Pen

  • Press the suction pen's power button to lift the chip.
Image showing the strong power suction feature of the station with various suction cup sizes and applications.

Figure 5: The strong power suction feature is ideal for removing ICs and other components, with various suction cup sizes available.

IV. Functions

Temperature Calibration

The station features a temperature calibration function. This function should be used when:

  • Replacing the heating element
  • Replacing the circuit board
  • Replacing other internal components of the machine
  • The surrounding environment has changed.

°C/°F Free Switching

The unit allows for easy switching between Celsius and Fahrenheit temperature displays.

Stand-by Mode

The station includes a stand-by mode for convenience and energy saving:

  • Hot Tweezer & Precision Soldering Station: Stand-by Timer can be set 1-10 Mins.
  • Suction Gun Sleep and Standby Function: 10-30 Mins can be set.

When the station(s) has entered stand-by mode, press their respective power button to restart the station. When in sleep mode, press the desoldering gun's trigger to wake the desoldering station. When in sleep mode, pick up the respective handpiece(s) to wake the hot tweezer soldering station or precision soldering station.

Menu Options Sequence

  • °C/°F Conversion Buzzer Prompt
  • → Stand-by Timer (Hot Tweezer Soldering Station)
  • → Stand-by Timer (Precision Soldering Station)
  • → Sleep Mode Timer (Desoldering Station)
  • → Stand-by Timer (Desoldering Station)
  • → Sleep Mode Timer (Desoldering Station)
  • → Stand-by Timer (Desoldering Station)
  • →Function Lock
  • →Password Change

5. Maintenance

V. Maintenance & Precautions

Soldering Station

  1. If a layer of oxidization forms on the surface of the soldering iron tip, a misconception can be created that the tip cannot heat up properly to melt the solder and do the tinning. But the actual temperatures of both the heating element and tip are high. In such an instance, please do not increase the temperature value further but use a metal wool ball to remove the oxidization following the steps below:
    1. Set the temperature to 300°C (572°F).
    2. Once the temperature stabilizes, gently rub the soldering iron tip inside the metal wool ball.
    3. When the oxidization is partially removed, continue applying solder onto the soldering iron tip while rubbing it until the tip is completely coated with solder. If the tip is too severely oxidized beyond cleaning, replace it with a new one.
  2. DO NOT use metal files to remove the oxidization on the soldering iron tip. If the soldering iron tip deforms or rusts, replace the soldering iron tip with a new tip.
  3. DO NOT apply excessive force on the soldering iron tip when soldering. This will not only not improve the heat transfer but damage the soldering iron tip instead.
  4. When placing the soldering iron back in the holder to idle after a high-temperature operation, adjust the temperature to 250°C (482°F) or below for idling. Failure to do so and leaving the soldering iron tip to idle on a high-temperature setting will cause the accelerated aging of the heating element and shorten the lifespan of the heating element and soldering iron tip.
  5. After every operation, clean the soldering iron tip, then tin the tip with a new layer of solder to prevent oxidization.

Hot Air Rework Station

  1. Keep the air outlet clear and free of blockages at all times.
  2. The installation of the hot air gun nozzles MUST be carried out ONLY when the nozzle enclosure and nozzle have cooled. Install the nozzle correctly. DO NOT install the nozzle with brute force, pull the edge of the nozzle with tweezers, or over-tighten the screws.
  3. Select the appropriate nozzle based on your operation requirement (temperatures may vary when you use nozzles in different diameters). When using nozzles smaller than the stock nozzles, you MUST use the maximum air volume with a relatively lower temperature setting. Complete this operation in the shortest duration possible to prevent damaging the hot air gun.
  4. Keep a minimum distance of 2mm between the component and the hot air gun's nozzle.
  5. DO NOT allow the hot air to come in direct contact with facial parts and beware of the danger of burn injuries. Upon the first use, the hot air gun may emit white fumes, and the white fume will dissipate in a short while.

NOTE: The station's hot air gun and soldering iron handles use high-strength stainless steel tubes. The station goes through no less than 4 cycles of testing, inspection, and calibration procedures under standard operation conditions. The steel tube may exhibit light bronze color as a result of our quality control efforts. It is normal to have a slightly bronzed steel tube when using a brand-new station; Rest assured for regular usage.

Desoldering Station Cleaning

  1. Cleaning the Desoldering Nozzle and Heating Element:

    CAUTION: The solder in the heating element's inner hole must ONLY be cleaned when completely melted. If the cleaning pin cannot be put through the heating element's inner hole, replace the heating element.

  2. Desoldering Nozzle Replacement: Remove the filter chamber and desoldering nozzle (Reference: Section 5 Cleaning: Filter Chamber and Section 7 Desoldering Nozzle Replacement) and then remove the locking screws to open the handpiece's case. Make sure the wire's correct polarity is noted before removal. Remove the heating element's wire to remove the heating element. Assemble the desoldering gun in the reverse order of the disassembly and calibrate the temperature.
  3. Filter Chamber Cleaning: The filter chamber can only be removed after the desoldering has fully cooled! Press the desoldering gun's trigger and observe the color of the indicator. If the red area is greater than or equal to the blue area, it indicates that you need to clean the desoldering nozzle, heating element, and filter chamber. Replace the respective components inside the filter chamber if any of the following conditions occur:
    • Unable to remove the solder from the spring filter, or the filter has collected more than 2/3 of solder of its capacity - Replace the spring filter.
    • The retainer has hardened and cracked - Replace the retainer.
    • The ceramic filter paper is hardened due to the over-accumulation of solder and flux - Replace the ceramic filter paper.

6. Troubleshooting Guide

VI. Troubleshooting Guide

  1. S-E: This is an indication that the station's sensor module is faulty. You need to replace the heating element (the heating element and the sensor modules). Or the handle has not been connected (Turn OFF the power, connect the handle, then turn ON the station again.)
  2. OCP: This is an indication that the heating element is defective and needs to be replaced.

7. Specifications

FeatureDetail
Model948D V
Rated Voltage Range220V-240V~
Rated Frequency50Hz
Rated Power490W (245 Heating Element), 410W (210 Heating Element)
Control Unit DimensionsL300xW340xH145mm ±10mm
Operating Ambient Temperature0°C~40°C/32°F~104°F
DisplayLED Nixie
Air Delivery (Hot Air Pencil)Pump Blower, 10L/min (Air Outlet Diameter: 4mm)
Temperature Range (Hot Air Pencil)100°C~480°C/212°F~896°F
Temperature Range (Soldering Station)90°C~450°C/194°F~842°F
Soldering Tip to Ground Resistance (Soldering Station)<2 ohms
Temperature Range (Desoldering Station)380°C~480°C/716°F~896°F
Suction Pressure (Desoldering Station)0.05MPa (measured from the nozzle)
Soldering Tip to Ground Resistance (Desoldering Station)<2 ohms
Temperature Range (Hot Tweezer Soldering Station)90°C~450°C/194°F~842°F
Soldering Tip to Ground Resistance (Hot Tweezer Soldering Station)<2 ohms
CertificationCE, RoHS

8. User Tips

  • Always ensure proper ventilation when soldering or desoldering to avoid inhaling fumes.
  • Regularly clean soldering iron tips and desoldering nozzles to maintain optimal performance and extend tool life.
  • Utilize the stand-by mode to save energy and prolong the lifespan of heating elements during breaks in work.
  • For delicate SMD components, use the hot tweezers for precise removal and installation.
  • When using the hot air gun, select the appropriate nozzle size and airflow to prevent damage to surrounding components.

9. Frequently Asked Questions (FAQ)

Q: How do I switch between Celsius and Fahrenheit?

A: Access the menu options and select the °C/°F Conversion setting to toggle between the two units.

Q: What should I do if the soldering iron tip is oxidized?

A: Do not use metal files. Instead, set the temperature to 300°C (572°F), gently rub the tip with a metal wool ball, and apply solder while rubbing until the tip is fully coated. If severely oxidized, replace the tip.

Q: Why is my desoldering station showing "Pht"?

A: "Pht" indicates that the desoldering station is pre-heating. The vacuum pump will not activate until the pre-heating process is complete and the station is ready for use.

Q: The hot air gun is not blowing air. What could be the problem?

A: Check if the hot air gun is properly connected to the station. Ensure the air outlet is clear of blockages. If the issue persists, refer to the troubleshooting section for error codes like "S-E" or "OCP" which might indicate a faulty sensor or heating element.

10. Warranty and Support

Guangzhou Yihua Electronic Equipment Co., Ltd. reserves the right to improve and upgrade products. Product specifications and design are subject to change without notice.

For any support or inquiries, please contact:

  • Address: No.13 ShaJing East Road, YongXing Industrial District, LongGui, GuangCong Road, GuangZhou, GuangDong
  • TEL: +86-20-87470526
  • FAX: +86-20-87470261

This product should not be thrown in the garbage. In accordance with the European directive 2012/19/EU, electronic equipment at the end of their life must be collected & returned to an authorized recycling facility.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.