1. General Information
The EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
1.1 Indications for Use
The Myoslim EMS Body Sculpt machine is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.4 Description of the Device
The EMS Body Sculpt enables a simple and effective treatment process that you can easily perform by adjusting the digital energy selection treatment plan or diagnostic procedure. Additionally, any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.
1.5 Contraindications
Do NOT use this device if any of the following apply:
- Wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patient.
- Patients with infectious diseases.
- Pregnant women, lactating women, menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
2. Safety Precautions and Warnings
Precautions before use:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Set to the lowest level initially, then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation, and try to eat after one hour after the operation.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
Front view of the instrument:
Note: The handle can only be used by the original machine and cannot be used interchangeably.
Magnetic thin handle plug:
3.2 Handle
3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| 3 | 7*100CM Belt | 2 | |
| 4 | Power cable | 1 | |
| 5 | Electronic manual | 1 copy |
4. Device Installation
-
Handle Film
Stick the black film to the working part of the handle.
-
Installing the Handle
Align the hole and fasten the clip. Lock the key ring when done.
-
Connect Power
Connect one end of the power cord to the machine and the other end to the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
-
Press on the Back Switch
Turn the power on (light on) or off (light not on) using the switch on the back.
-
Press the Front Switch
Single-click to power on. Long press to power off.
5. Basic Device Operation
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:
5.3.1 Setting the Therapy by Controls
Mode 1: The operation interface of mode 1 allows you to select the user part, gender, age, and other detailed questions and energy. The frequency of mode one is 5-60Hz.
Mode 2: Mode 2 allows you to select a more detailed energy level and adjust it according to your own situation. The frequency of mode two is 30-100Hz.
5.4 Unit Settings
The device offers various settings for customization:
- Language settings: Adjust the display language.
- Sound adjustment: Control the device's sound output.
- Bright adjustment: Adjust screen brightness for optimal visibility.
- Set date time: Configure the current date and time.
- System adjustment: Access system-level configurations.
- Technician: Access advanced settings, typically password-protected.
6. Therapy
6.1 Preparing the Therapy
- Communicate with patients.
- Ensure good health.
- Stay hydrated.
- Wear appropriate clothing.
- Avoid eating in large quantities.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol.
6.2 Placing the Handle
The handles can be placed on various body parts using the provided belts for targeted treatment.
7. Maintenance and Repair
7.1 Maintenance
- Daily inspection: Regularly inspect instruments and components. Ensure the power socket has a reliable connection to the ground. Check if the power cord is damaged before use; if so, stop using the instrument.
- Cleaning: Clean the instrument regularly to ensure sanitation. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off.
- Replacing the fuse: When replacing the fuse, turn off the power and unplug the power plug to prevent electric shock.
7.2 Repair
After purchasing the instrument, fill in the warranty card and send it to the manufacturer or agent for warranty. A free warranty is provided for one year from the purchase date for product quality problems (warranty limited to the instrument host, excluding accessories and consumables). After the warranty period, contact the manufacturer for paid after-sales service. Do not repair the machine without authorization.
8. Troubleshooting
8.6 Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | The power plug is not inserted into the socket Power switch not on Power fuse failure |
Check the power Check the power switch Replace the fuse |
| Handle not working | Check the handle for loose connection | Reseat the handle |
9. Specifications
Technical Parameters
| Name | Value |
|---|---|
| Model | E-11 |
| Input power supply | AC110V-220V 50/60Hz |
| Output maximum power | 0-6000W |
| Frequency | 5-200HZ |
| Screen size | 7.0 inches |
| Machine color | White |
9.1 Electromagnetic Compatibility (EMC)
Radiated Electromagnetic Field Immunity Test:
- Port: Enclosure
- Basic Standard: IEC 61000-4-3:2020
- Test Level: 30V/m with 80% AM. 1kHz Modulation.
- Standard require: A
- Tester: Sam Liu
- Temperature: 25°C
- Humidity: 54%
Test Equipment:
| Description | Manufacturer | Model | Identifier | Cal. Date | Cal. Due |
|---|---|---|---|---|---|
| Signal Generator | IFA | 2023B | N/A | 15/03/2022 | 14/03/2023 |
| Power Amplifier | AR | 150W1000 | N/A | 15/03/2022 | 14/03/2023 |
| Power Antenna | AR | 25S1G4A | N/A | 15/03/2022 | 14/03/2023 |
Block Diagram of Test Setup:
10. Warranty and Support
The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) if it has an intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates may incur appropriate fees. If the instrument breaks and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping cost. After six months, the buyer bears all shipping costs.
Free warranty service is not provided for failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
11. Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
User Tips
- For optimal results, ensure the operating environment is clean, well-lit, and has good ventilation.
- Always remove metal jewelry before using the device.
- Start with the lowest intensity level and gradually increase it based on your comfort and skin tolerance.
- Stay hydrated and wear appropriate clothing during therapy sessions.
- The device is designed for non-invasive body sculpting, offering a comfortable experience with short recovery times.
- Utilize the touch-controlled display to easily adjust settings and monitor your treatment progress.
- Regular use, combined with a healthy lifestyle, can help achieve significant muscle building and fat reduction.