1. Introduction
The MYOSLIM PHYSIO MAGNETO Electromagnetic Therapy Device utilizes advanced Pulsed Electromagnetic Field Therapy (EMTT) for non-invasive pain relief, musculoskeletal recovery, fat reduction, and body contouring. This device is designed for both clinical and home use, offering a safe and drug-free alternative for various conditions.
Product Overview Video
This video demonstrates the basic operation and features of the PHYSIO MAGNETO device.

The PHYSIO MAGNETO device is designed to resolve pain problems in all areas, providing comfortable electromagnetic transduction therapy.
2. Important Safety Warnings
- Do not use the device on the heart area, head area, or on patients with implants (e.g., pacemakers, metal implants).
- Consult a medical professional before use if you have any pre-existing medical conditions.
- Keep the device out of reach of children.
- Ensure the device is properly grounded during operation.
- Do not operate the device if it is damaged or malfunctioning.
- Avoid direct contact with water or other liquids.
3. Components
The PHYSIO MAGNETO device typically includes the following components:
- Main control unit with HD touchscreen interface.
- Ring-shaped focused energy handle.
- Adjustable positioning bracket (360° telescopic multi-angle adjustable stand).
- Power cable.
- Optional accessories may include 4 RF handles and a pelvic stimulation pad.

Front view of the PHYSIO MAGNETO device, showing the main unit and ring handle.

Side view of the PHYSIO MAGNETO device.

Back view of the PHYSIO MAGNETO device.

Top view of the PHYSIO MAGNETO device.
4. Setup Instructions
The PHYSIO MAGNETO device features a 3-step simple startup process, making it beginner-friendly.
- Unpacking: Carefully remove all components from the packaging.
- Assembly:
- Attach the adjustable positioning bracket to the main unit.
- Connect the ring-shaped focused energy handle to the bracket and the main unit. Ensure all connections are secure.
- Power Connection: Plug the power cable into the device and then into a suitable electrical outlet (50-1000V AC).

The device features an adjustable height and free telescoping stand for optimal positioning.
5. Operating Instructions
The device features an HD touchscreen interface for easy control of modes, energy, and language settings.
5.1. Initial Power On and Settings
- Press the power button to turn on the device.
- The HD touchscreen will display the main interface.
- Language Selection: Navigate to the language settings to choose your preferred language (e.g., English, Chinese, Portuguese, Spanish, Russian, French, Japanese, Korean).
- Brightness/Volume Adjustment: Adjust screen brightness and sound volume as needed.
- Customer Information: Input relevant customer information if required for record-keeping.

The user-friendly interface allows for easy mode selection, energy regulation, and language/brightness/volume adjustment.
5.2. Treatment Parameters
The device offers various modes and adjustable parameters for customized treatment.
- Mode Selection: Choose between different treatment patterns (e.g., Pattern 1, Pattern 2) based on the desired therapy.
- Time Adjustment: Set the treatment duration using the 'Time' controls.
- Energy Regulation: Adjust the energy level (e.g., 0-100Hz) using the 'Energy' controls. The stimulus strength can reach up to 6T.
- Frequency Adjustment: Fine-tune the oscillation frequency (e.g., 5Hz, 10Hz, 27Hz, 31Hz, 50Hz) as per treatment requirements.
5.3. Applying the Ring Handle
The ring handle is designed for versatile application across various body parts.
- Position the ring handle over the target treatment area. The 360° telescopic positioning bracket allows for precise placement without needing to hold the handle manually.
- Ensure the handle is stable and securely positioned.
- Initiate the treatment by pressing the start button on the interface.

The ring handle is suitable for use on all parts of the body, including arms, back, and waist.
6. Detailed Treatment Area Guides
The PHYSIO MAGNETO device can be applied to various parts of the body for pain relief, fat reduction, and skin tightening. Always ensure multi-level nursing is carried out from shallow to deep, and for repeated care, use a horizontal and vertical composite method.

Full body treatment areas include back, arm, elbow, waist, knee, and foot.
6.1. Facial Treatment Areas

Facial treatment areas include forehead, eyebrows, cheeks, and jawline for wrinkle reduction, lifting, and skin tone improvement.
6.1.1. Forehead and Around the Eye Sockets
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 1.5mm | 0.1-0.2J | 1.0-1.5mm | 1 | 120 |
Precautions:
- Do not directly treat the orbital or cervical nerve area.
- Adjust the dot pitch between 10mm and 15mm before care.
- Ensure the patient closes their eyes when treating the orbital area.
- When treating the periorbital area and eyebrow line, pull the tip of the probe firmly to the forehead to relieve pain.
6.1.2. Fine Lines and Deep Wrinkles (2.0mm Probe)
| Area | Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|---|
| Forehead | 2.0mm | 0.1-0.2J | 1.4-1.5mm | 1 | 90 |
| Around the eyes | 2.0mm | 0.1-0.2J | 1.4-1.5mm | 1 | 100 |
| Around the mouth | 2.0mm | 0.1-0.2J | 1.4-1.5mm | 1 | 80 |
Precautions:
- Do not directly treat the supraorbital or cervical nerve area.
- Adjust the point spacing between 10mm and 15mm before care.
- Ensure the patient closes their eyes when treating the orbital area.
- Pull the tip of the probe firmly to the forehead and output energy to relieve pain.
- For repeat care, apply the processing mode as instructed.
6.1.3. Jaw and Neck
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 4.5mm | 0.5-0.8J | 1.0-1.5mm | 1 | 135 |
| 3.0mm | 0.3-0.5J | 1.0-1.5mm | 1 | 135 |
| 1.5mm | 0.1-0.2J | 1.0-1.5mm | 1 | 65 |
Precautions:
- Do not directly treat the marginal mandibular nerve area.
- Do not apply too much pressure on the neck to prevent impermeability during care.
- In multi-level nursing, nursing should be carried out from deep to shallow.
- For repeat care, apply the processing mode as instructed.
6.2. Body Treatment Areas
6.2.1. Upper Arm
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 6.0mm | 0.8-1.5J | 1.0-1.5mm | 2 | 75/75 |
| 4.5mm | 0.6-1.0J | 1.0-1.5mm | 2 | 75/75 |
| 3.0mm | 0.6-0.9J | 1.0-1.5mm | 2 | 75/75 |
Precautions:
- Do not directly treat the nerve area.
- In multi-level nursing, nursing should be carried out from shallow to deep (e.g., 4.5mm-3.0mm-1.5mm).
- For repeat care, use the horizontal and vertical composite method as shown in the diagram.
6.2.2. Knee
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 6.0mm | 1.0-2.0J | 1.0-1.5mm | 2 | 30/30 |
| 4.5mm | 0.6-0.9J | 1.0-1.5mm | 2 | 30/30 |
| 3.0mm | 0.6-0.8J | 1.0-1.5mm | 2 | 30/30 |
Precautions:
- Do not directly treat the nerve area.
- In multi-level nursing, nursing should be carried out from shallow to deep (e.g., 4.5mm-3.0mm-1.5mm).
- For repeat care, use the horizontal and vertical composite method as shown in the diagram.
6.2.3. Chest and Shoulder
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 4.5mm | 0.2-0.4J | 1.0-1.5mm | 1 | 120 |
| 3.0mm | 0.2-0.4J | 1.0-1.5mm | 1 | 120 |
| 1.5mm | 0.1-0.2J | 1.0-1.5mm | 1 | 40 |
Precautions:
- Do not directly treat the clavicle, breast tissue, or breast implant area.
- In multi-level nursing, nursing should be carried out from deep to superficial (e.g., 4.5mm-3.0mm-1.5mm).
- For repeat care, apply the processing mode as instructed.
6.2.4. Waist
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 13.0mm | 0.8-1.3J | 1.0-1.5mm | 3 | 300/300 |
| 9.0mm | 0.8-1.5J | 1.0-1.5mm | 3 | 300/300 |
| 6.0mm | 0.6-1.2J | 1.0-1.5mm | 3 | 300/300 |
Precautions:
- Do not directly treat the PSIS (Posterior Superior Iliac Spine) or the pelvic area.
- In multi-level nursing, nursing should be carried out from deep to superficial (e.g., 4.5mm-3.0mm-1.5mm).
- For repeat care (3 times), use the horizontal and vertical compound method as shown in the diagram.
6.2.5. Armpit
| Probe | Energy | Dot Pitch | Repeat | Number of Shots |
|---|---|---|---|---|
| 6.0mm | 0.6-0.9J | 1.0-1.5mm | 2 | 20/20 |
| 4.5mm | 0.5-0.8J | 1.0-1.5mm | 2 | 20/20 |
| 3.0mm | 0.5-0.8J | 1.0-1.5mm | 2 | 20/20 |
Precautions:
- Do not directly treat breast tissue or the ulnar nerve.
- In multi-level nursing, nursing should be carried out from deep to superficial (e.g., 4.5mm-3.0mm-1.5mm).
- For repeat care, use the horizontal and vertical composite method as shown in the diagram.
7. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Device Name | Physio Magneto Electromagnetic Transduction Therapy Machine |
| Handle Type | Ring-Shaped Focused Energy Handle |
| Power Supply | Alternating Current |
| Voltage | 50-1000V AC |
| Oscillation Frequency | Up to 100Hz (Adjustable) |
| Penetration Depth | Up to 18cm (Targets Deep Tissues/Bones) |
| Target Conditions | Musculoskeletal Disorders, Chronic Pain, Sports Injuries |
| Cooling System | Intelligent Variable-Frequency Air Cooling (Zero Leak Risk) |
| Positioning Bracket | 360° Telescopic Multi-Angle Adjustable Stand |
| Operation Steps | 3-Step Simple Startup (Beginner-Friendly) |
| Interface | HD Touchscreen (Mode/Energy/Language Adjustment) |
| Safety Profile | Non-Systematic Therapy (Minimal Side Effects, Non-Addictive) |
| Maintenance Cost | Zero Maintenance (No Fluid Change Required) |
| Applicable Users | Chronic Pain Patients, Athletes, Post-Surgery Recipients |
| Curative Effect | Reduces Pain/Swelling, Improves Mobility & Tissue Regeneration |
| Material | ABS |
| Size (Device) | 36*28*64cm |
| Weight (Device) | 18.5KG |
| Origin | Mainland China |
| Certification | CE, RoHS |
8. Maintenance
The PHYSIO MAGNETO device is designed for zero maintenance, requiring no fluid changes due to its intelligent variable-frequency air cooling system.
- Cleaning: Wipe the device and handles with a soft, dry cloth after each use. For disinfection, use a mild, non-abrasive disinfectant.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Inspection: Periodically inspect the power cable and connections for any signs of wear or damage.
9. Troubleshooting
If you encounter any issues with your PHYSIO MAGNETO device, please refer to the following common troubleshooting steps:
- Device Not Powering On:
- Ensure the power cable is securely connected to both the device and the power outlet.
- Check if the power outlet is functional by plugging in another appliance.
- Verify the power switch on the device is in the 'ON' position.
- No Output from Handle:
- Ensure the handle is correctly attached to the main unit.
- Check the selected mode and energy settings on the touchscreen. Increase energy if necessary.
- Verify that the treatment has been started on the interface.
- Screen Unresponsive:
- Restart the device by turning it off and on again.
- If the issue persists, contact customer support.
For any issues not covered here, please contact customer support for assistance.
10. User Tips
- Start Low, Go Slow: When beginning a new treatment, start with lower energy settings and gradually increase them as your comfort level allows.
- Consistent Application: For best results, maintain a consistent treatment schedule as recommended by a professional or as outlined in the treatment guides.
- Hydration: Ensure adequate hydration before and after treatments to support tissue regeneration and overall well-being.
- Proper Positioning: Utilize the adjustable stand to position the handle precisely, allowing for hands-free operation and optimal focus on the treatment area.
- Listen to Your Body: If you experience any discomfort or unusual sensations, reduce the energy level or stop the treatment immediately.
11. Warranty and Support
The MYOSLIM PHYSIO MAGNETO device comes with a comprehensive warranty and dedicated customer support.
11.1. Warranty Information
The product is backed by a service commitment that aims to provide sincere service for a lifetime. Your encouragement is the greatest motivation for our progress.
The device is CE and RoHS certified, ensuring compliance with international safety and quality standards.
11.2. Customer Support
For any questions, technical assistance, or warranty claims, please contact your vendor or refer to the official product website for support channels.
12. Additional Resources
For a more detailed guide and further documentation, please refer to the official user manual PDF: