MYOslim 6500W 15T RF Body Shaping Machine

Contents

MYOslim 6500W 15T RF Body Shaping Machine User Manual

Muscle Stimulation, Slimming, Weight Loss, and Body Shaping Device

1. Product Overview

The MYOslim 6500W 15T RF Body Shaping Machine is a professional-grade device designed for body contouring, muscle stimulation, and fat reduction. It utilizes high-intensity focused electromagnetic energy and advanced RF roller technology to enhance body shaping and promote muscle gain without invasive procedures.

MYOslim 6500W 15T RF Body Shaping Machine
Front view of the MYOslim 6500W 15T RF Body Shaping Machine.
MYOslim 6500W 15T RF Body Shaping Machine with screen displaying settings
The machine features a touch screen interface for function selection and parameter adjustment.
Left side view of the MYOslim 6500W 15T RF Body Shaping Machine
Left side view of the MYOslim machine.
Right side view of the MYOslim 6500W 15T RF Body Shaping Machine
Right side view of the MYOslim machine.
Back view of the MYOslim 6500W 15T RF Body Shaping Machine showing power and handle connections
Back view of the MYOslim machine with power input and handle connections.
Demonstration of the MYOslim 6500W 15T RF Body Shaping Machine in use, highlighting its features and application.

2. Safety Information

2.1 General Safety Matters

  • Crucial: Remember not to start without water. Operating the device without sufficient water can cause severe damage to the treatment gun.
  • This operating system contains precision instruments. Do not attempt to move the machine over long distances.
  • Before transporting, ensure all water is drained from the instrument. Use the original shock-absorbing packaging to prevent optical system misalignment and energy output issues.

2.2 Electrical Safety

  • The device uses a single-phase 220V power supply with a maximum output current of no more than 5A.
  • To extend the machine's service life and reduce the impact of grid fluctuations, use a 1000W stable power supply.

2.3 Operation Safety

  • It is forbidden to place reflective materials (e.g., watches, mirrors, jewelry) in the treatment room during operation.
  • Keep the light guide system clean at all times. Ensure condensate does not contaminate the light guide system.

2.4 System Safety Device

  • This product strictly adheres to (E light) enterprise standards for safe use.
  • Always fill with water before starting to prevent damage to the treatment gun.
  • Check the circuit for safety immediately after power on and continuously throughout the operation.
  • Before treating skin, always perform a test by 'hitting and firing two empty guns' first.

3. Setup and Installation

3.1 Water Installation

  1. Use only pure water or distilled water. Do NOT use mineral water or tap water, as these can damage the water circulation refrigeration system over time.
  2. When adding water, open the overflow hole. Continue adding water until it flows out of the overflow hole, indicating the instrument is full.
  3. After the initial water fill, turn on the machine and operate it for 2-3 minutes to ensure proper circulation and refrigeration.

3.2 Water Change Frequency

  • For frequent use, it is recommended to change the water every 15 days.
  • For infrequent use, change the water once a month.

4. Operating Instructions

4.1 Startup and Interface Navigation

  1. Startup Screen: Upon powering on, the device will display a 'WELCOME' screen. You can access background settings from here.
  2. Function Selection: The main interface allows you to select various treatment modes such as Hair Removal, Skin Rejuvenation, Pigmentation, Vascular Therapy, and Acne Therapy. The device may have two different styles of operation interfaces (A and B).
  3. Language Settings: The instrument supports multiple languages including Simplified Chinese, English, Traditional Chinese, Portuguese, Vietnamese, and Korean. This can be adjusted in the background parameter settings.
  4. Password Protected Settings: Some background parameter settings (e.g., total light output count, working mode, interface style) require a password (050128) provided by the manufacturer.

4.2 Treatment Modes and Parameters

The device features an advanced RF Roller technology that rotates 360 degrees, heating up quickly to burn fat and restore body shape. It also helps improve muscle definition for a more toned and sculpted look.

2 in 1 Inner Ball Roller Machine for body slimming
The 2-in-1 Inner Ball Roller Machine combines micro-vibration and RF for skin tightening, cellulite reduction, pain relief, and body contouring.
RF Roller handles for body and face/neck
The RF roller heats up quickly and rotates 360 degrees for effective fat burning and body shaping. Includes both body and face/neck rollers.
Product display showing big wheel and small wheel rollers
The device comes with a 'Big Wheel' for body treatment and a 'Small Wheel' for face and neck areas.
Lighting effect of the big wheel and small wheel rollers during use
The rollers feature a lighting effect when in use, indicating activation.
Roller ball material for face/neck and body rollers
Close-up of the roller ball material for both face/neck and body rollers.
Diagram illustrating the working principle of the roller and its effects
Roller Working Principle: The inner ball roller machine is a non-invasive mechanical combination of micro + infrared treatment. It generates micro-vibration by rolling silicone balls 360 degrees, exerting pressure on the skin. This creates a 'pulsation compression' effect, stimulating deep muscle contractions and promoting muscle gain. It reshapes contours, tones muscles, improves oxygen, eliminates pain, drains toxins, and enhances blood circulation.

4.2.1 Hair Removal Operation

  • Pulse Width: Refers to the working time of the first strong pulse.
  • Pulse Interval: Refers to the time interval between the first and second pulse.
  • Number of Pulses: A greater number of pulses increases the depth of light on the skin, used for deeper problems.
  • Refrigeration Adjustment: Adjusts the cooling temperature of the bald head (5 levels). More blue snowflakes indicate stronger refrigeration; no blue snowflakes means refrigeration is off.
  • Energy Adjustment: It is recommended to start at an energy glazing of 15. Adjust by 2-3 units at a time, in consultation with the customer. Avoid high-energy skin burns; use the skin's thermal sensation as a guide.
  • Default Settings: Pulse width, interval, and number of pulses are recommended to be set to default data.
  • Hair Removal Course: Typically one course involves 4-6 treatments, 2-3 times every 28 days, for obvious results. Hair may become slightly curly or burnt.
  • During epilation, a slight tingling sensation and a faint burning odor may be experienced in treated areas (e.g., armpit, hairline, extremities). This is normal.

4.2.2 Skin Rejuvenation Operation

  • Course: One course typically involves 4-6 treatments, 2-3 times every 3 weeks, for obvious results (face treatment: approximately 30 minutes).
  • Preparation: Deep cleansing, exfoliation, and addressing acne/blackheads.
  • Red Blood and Acne Removal: 1-2 courses, 4-6 treatments, 2-3 times every 3 weeks for obvious results. Symptoms may include redness, which can be alleviated with cold spray or ice packs.
  • Freckle Removal: 1-2 courses (for severe melasma, 2 courses), 4-6 treatments, once every 3-4 weeks. The spot may initially become darker and slightly reddish, then pale and fall off within a week.
  • Post-Treatment Care: Due to individual physical differences, some customers may experience temporary discomfort, small blisters, pigmentation, redness, swelling, and bruises. It is recommended to apply ice packs for 30 minutes after treatment and continue care for 5 days.

4.3 Starting and Stopping Treatment

  1. After selecting the desired treatment mode, press the "Ready" button on the interface. This will trigger the bald head and automatically charge the capacitor.
  2. Once charging is complete, the device enters the treatment state.
  3. To stop treatment and enter standby mode, press the "Standby" key.

4.4 Laser Working Interface (A & B)

The laser working interface displays the current laser mode, frequency, energy, and temperature. It also includes controls for:

  • Light Output Frequency Adjustment: Use the triangle arrows to increase or decrease the frequency. Factory settings are usually optimized; consult the manufacturer for specific details.
  • Light Output Energy Adjustment: Use the triangle arrows to increase or decrease energy. Factory settings are usually optimized; consult the manufacturer for specific details.
  • Temperature Display: Shows the current working environment temperature. A normal display is green; a red thermometer indicates an abnormal temperature.
  • Water Flow Display: Shows the current water flow. A normal display is green; a triangle exclamation mark in the lower right corner of the cup indicates abnormal water flow.
  • Light Count: Click this area to clear the count.
  • Preparation for Light Output: Click this area and press the handle pedal to activate light output.
  • Light Output Standby: Release the handle pedal and click the area to stop the instrument from working.
  • Return: Click this area to return to the previous menu.

5. Maintenance

  • Water Quality: Always use pure or distilled water. Change water every 15 days for frequent use, or monthly for infrequent use.
  • Cleanliness: Keep the light guide system clean at all times. Prevent condensate from contaminating it.
  • Storage: Store the device in a stable environment. If transporting, ensure water is drained and original packaging is used.
  • Software Settings: Avoid changing alarm temperature or water flow switch settings without manufacturer permission.

6. Troubleshooting

  • Device Not Starting/Working: Check if the device is properly filled with pure/distilled water. Ensure the power supply is stable (1000W recommended).
  • Abnormal Temperature: If the temperature display shows a red thermometer, the working environment temperature is abnormal. Stop operation and allow the device to cool down or check ambient conditions.
  • Abnormal Water Flow: If a triangle exclamation mark appears in the water flow display, there is an issue with water circulation. Check water levels and ensure no blockages.
  • Optical System Issues: If the optical system is out of alignment or energy output is affected, it may be due to improper handling or transportation without original packaging. Contact support.
  • Treatment Gun Damage: Operating without water will burn the treatment gun. Ensure water is always present before starting.

7. Specifications

FeatureSpecification
Power SupplyAlternating Current (AC220V/50Hz or AC110V/60Hz)
Voltage50-1000V AC
MaterialABS
Item TypeMassage & Relaxation
ApplicationCommercial, Beauty Center
TypeDesktop
FunctionsBody contouring, body slimming, body sculpt, muscle build, fat removal, skin tightening, butt lift, muscle stimulation, EMS Cellulite Reductions
LanguageEnglish/Customized
CertificationCE, RoHS
Package Dimensions (L x W x H)60 cm x 51 cm x 52 cm
Package Weight27.05 kg
Max Output Current (220V)5A
Recommended Stable Power Supply1000W

8. Contraindications

Do not use this device if any of the following conditions apply:

  • Photosensitivity.
  • Recent intake of photosensitive foods or drugs (e.g., celery, isotretinoin).
  • Presence of a pacemaker or defibrillator in the body.
  • Damaged skin at the treatment site.
  • Pregnancy, diabetes, heart disease, hypertension, or epilepsy.
  • Skin cancer.
  • Fragile skin recently exposed to the sun.

9. User Tips

  • Ease of Use: The device is designed for easy operation. Detailed instructions and video tutorials are available to guide even beginners.
  • Usage Duration: Follow the recommended usage guidelines, typically 20-45 minutes per session, 2-3 times per week.
  • Prevent Overheating: The device has built-in temperature control. To extend its lifespan, take a 10-minute break after continuous use for more than 30 minutes.
  • Water Purity: Always use pure or distilled water to prevent damage to the internal cooling system.
  • Spot Test: Before performing a full treatment, always conduct a spot test to assess skin reaction and adjust energy levels accordingly.
  • Medical Consultation: If you have any special medical conditions (e.g., pregnancy, heart disease, high blood pressure), consult a doctor before using the device.

10. Frequently Asked Questions (FAQ)

Q1: Is this product covered by a warranty?
A: Yes, we offer a one-year warranty, including free repair or replacement for non-intentional damage.
Q2: How do I use this product? Is it difficult to operate?
A: It's very easy. We provide detailed instructions and video tutorials, making it easy for even beginners.
Q3: How long can I use it daily?
A: We recommend using it as often as recommended in the manual, typically 20-45 minutes per session, 2-3 times per week.
Q4: Will the device overheat? Does it require a break?
A: The device has built-in temperature control. We recommend taking a 10-minute break after continuous use for more than 30 minutes to extend its lifespan.
Q5: Who is it suitable for?
A: It's suitable for most people. If you have any special medical conditions (pregnant women, heart disease, high blood pressure, etc.), please consult a doctor first.

11. Warranty and Support

11.1 Warranty Information

  • The machine is guaranteed for one year from the date of purchase (with the bill). Quality problems within this period will be repaired free of charge.
  • After one year, maintenance fees will be charged.
  • Accessories are guaranteed for three months. Quality problems within this period will be repaired free of charge. After three months, parts maintenance fees will be charged.
  • For items outside the warranty period, maintenance services are available, with charges for spare parts and consumables.

11.2 Warranty Exclusions

No free warranty service is provided for failures caused by personal reasons, including but not limited to:

  • Disassembly or modification of the product without permission.
  • Failure caused by accidental drops or falls.
  • Malfunctions due to lack of reasonable maintenance.
  • Failures resulting from not following the correct instructions in this manual.

11.3 Support

  • Our service includes 24 hours online support.
  • For specific details, password access, or technical assistance, please contact the manufacturer or authorized service provider.

For a detailed PDF version of the user manual, please refer to the official document: User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.