1. Product Overview
The HLK-LD2452 is a high-precision multi-target recognition sensor designed for human target positioning and tracking within an area. It utilizes FMCW (Frequency Modulated Continuous Wave) technology to achieve real-time distance, angle, and speed measurement of targets.
This module is primarily applied in indoor environments such as smart homes, offices, and hotels for positioning and tracking multiple human bodies. It can detect up to 3 targets simultaneously.
Figure 1: HLK-LD2452 Radar Module Top View
Figure 2: HLK-LD2452 Radar Module Bottom View
Video 1: Animation demonstrating the HLK-LD2452 radar chip in operation.
2. Specifications
The HLK-LD2452 sensor features an AIoT millimeter wave radar chip, a high-performance one-transmitter two-receiver microstrip antenna, a low-cost MCU, and peripheral auxiliary circuits. The intelligent algorithm firmware uses advanced signal processing technology proprietary to FMCW waveform and millimeter wave radar chips.
2.1. Key Characteristics
- Frequency Band: 24 GHz ISM
- Integration: Intelligent millimeter wave radar single-chip with intelligent algorithm firmware
- Functionality: Accurate target positioning and tracking
- Size: Ultra-small module (23 mm x 42 mm)
- Environmental Temperature: -40°C to 85°C
- Power Supply: 5 V single power supply, compatible with 3.3 V power supply
- Maximum Detection Range: 6 m
- Angular Coverage: Azimuth angle ±60°, pitch angle ±30°
- Installation: Designed for wall-mounted installation
- Target Detection: Maximum detection of 3 targets
2.2. Detailed Specifications
| Parameter | Min | Typical | Max | Unit |
|---|---|---|---|---|
| Supporting frequency bands | 24 | - | 24.25 | GHz |
| Support maximum sweep bandwidth | - | 0.25 | - | GHz |
| Power supply voltage | 3.3 | 5 | 5 | V |
| Size | - | 23 X 42 | - | mm X mm |
| Ambient temperature | -20 | - | 70 | °C |
| Maximum sensing distance | - | 6 | - | m |
| Range resolution | - | 0.72 | - | m |
| Distance measurement accuracy | - | 0.15 | - | m |
| Angle accuracy | 2 | - | 20 | ° |
| Operating frequency band | 24 | - | 24.25 | GHz |
| Sweep bandwidth | - | 0.21 | - | GHz |
| Data refresh rate | - | 10 | - | Hz |
| Average working current | - | 126 | - | mA |
2.3. Mechanical Dimensions
The HLK-LD2452 hardware PCB has a length of 42.0 ± 0.2 mm and a width of 23 ± 0.2 mm. The total height with terminals is 5.2 ± 10% mm, and the substrate thickness is 1.2 ± 0.1 mm.
Figure 3: HLK-LD2452 Mechanical Dimensions Diagram (Top and Bottom Layers)
3. Setup and Installation
3.1. Product Pin Definition
The HLK-LD2452 module uses J1 as the power supply and communication interface (ZH1.5-4P connector) and J2 for MCU programming and testing contacts. Refer to the tables below for pin descriptions.
Figure 4: HLK-LD2452 Product Pin Definition Diagram
Table 3-1 HLK-LD2452 Hardware J1 Pin Description
| J# Pin# | Name | Function | Describe |
|---|---|---|---|
| J1 Pin1 | 5V | power input | 5 V power supply |
| J1 Pin2 | RX | UART RXD | Serial port reception |
| J1 Pin3 | TX | UART TXD | serial port transmission |
| J1 Pin4 | GND | grounding | - |
Table 3-2 HLK-LD2452 Hardware J2 Pin Description
| J# Pin# | Name | Function | Describe |
|---|---|---|---|
| J2 Pin1 | 5V | power input | 5 V power supply |
| J2 Pin2 | DP | Burning port data positive signal | - |
| J2 Pin3 | DM | Negative signal of burning port data | - |
| J2 Pin4 | DEBUG | Debugging serial port TXD | Used for firmware serial port debugging |
| J2 Pin5 | GND | grounding | - |
3.2. Connecting to Software
To use the HLK-LD2452 with its visualization software, follow these steps:
- Obtain the corresponding software package from the official Hi-Link website, unzip it, and navigate to the folder directory.
- Use a suitable cable to connect the radar module to a USB serial port tool, and then connect the tool to your computer.
- Double-click the executable file "HLK-LD2452.exe" in the software path to launch the application.
Figure 5: HLK-LD2452 Test Kit showing module, wire, and serial port board connection
3.3. Installation Recommendations
3.3.1. Radar Casing Requirements
If the radar is to be installed with a casing, the casing must possess good wave transmission characteristics in the 24 GHz frequency band. It must not contain metals or materials that shield electromagnetic waves. For detailed guidelines, refer to Hi-Link's "Millimeter Wave Sensor Antenna Cover Design Guide".
3.3.2. Wall Mounted Installation
The typical installation method is wall-mounted. The maximum positioning and tracking distance is 6 meters. When installing on a wall, consider potential occlusion and interference from above. It is recommended to install the module within a height range of 1.5 to 2 meters.
Figure 6: Schematic Diagram of Wall Mounted Installation
When installing on a wall, it is recommended to orient the radar as shown in Figure 7. The normal direction of the radar antenna plane should be 0°.
Figure 7: HLK-LD2452 Wall Mounted Installation Angle Identification
The radar's detection angle range is ±60° centered on the normal direction of the radar antenna plane. The maximum detection distance in the normal direction can reach 6 meters.
4. Operating Instructions (Software Usage)
The HLK-LD2452 software provides demonstration functions for single and multi-target detection, allowing users to customize monitoring areas and set detection blind spots. It also supports recording, saving, and replaying radar detection data.
4.1. Software Interface Overview
The visualization tool interface is divided into three main areas:
- Function Button Area: Used to check radar connection, start/stop data reception, set monitoring areas, switch detection modes, and manage data recording.
- Data Area: Real-time display of distance, angle, and velocity information of the tracked target.
- Target Display Area: Visually displays the position of the target being located and tracked within the detection area on the radar map.
4.2. Single/Multi Target Detection
- Connect the radar module and open the software as described in Section 3.2.
- Click the "Detect Device" button on the interface. A prompt box "Detected Serial Device" will appear if the connection is successful. Click "OK".
- Click the "Start/Stop" toggle button to begin displaying the position of the detected target relative to the radar.
- The software defaults to "Single Object Detection Demonstration". To switch to "Three Object Detection Demonstration" (which can display up to three targets with the highest motion energy), click the "Multi Object Detection/Single Object Detection" switch button. Clicking it again will revert to single object detection. Note that single target detection mode is not suitable for tracking multiple targets.
4.3. Regional Monitoring and Blind Spot Setting
Regional Monitoring: Allows users to define one or more polygon areas of interest within the detection area. When a human target enters a monitored area, its color changes. This feature enables selective display of radar data.
Blind Spot Setting: Allows users to disable detection and result display for specific distance areas, effectively blocking specified detection zones based on user-defined parameters.
- Start target detection as described in Section 4.2.
- Click the "Area Monitoring" button. An interface will appear for settings.
- To add a monitoring area, click the "Add Monitoring Area" button. Left-click to define vertices within the fan-shaped area on the interface, then right-click to finalize the polygon. The software will connect the vertices to form the monitoring area.
- (Optional) Repeat step 3 to set multiple monitoring areas.
- (Optional) To remove all monitoring areas, click the "Area Monitoring" button again and select "Delete All Monitoring Areas".
- To set blind spots, adjust the "Set visible area range" parameters. The default value (0 to -1) represents the maximum detection distance gate with no blind spots. Users can set nearest and farthest blind spots (e.g., 1 to 21).
4.4. Recording and Playback of Radar Data
- Connect the radar module and software, and select the appropriate target detection mode.
- When the "Start/Stop" toggle button displays "Start", click the "Save Path" button to set the directory for saving radar data. The default path is the SaveData folder within the software directory.
- The software's data saving function is off by default. To enable it, click the "Data Save" button when it is clickable. Clicking it again will disable the function.
- With "Data Save" enabled, click "Start" to begin target detection. The software will display human body information in the detection areas.
- Click the "Start/Stop" toggle button to stop detection. The saved radar data will be found in the specified path, named with a timestamp (yyyy_mm-dd_hhmm_sts).
- To play back recorded data, click the "detect playback/stop playback" switch button, select a radar data file from the storage path, and start playback.
- Click the "detect playback/stop playback" toggle button again to stop data playback.
4.5. Firmware Upgrade
The HLK-LD2452 module supports firmware upgrades using the "HLK-LD2452 IAP Tool".
- Obtain the upgrade tool from the official Hi-Link website.
- Connect the serial port adapter board and radar module as described in Section 3.2.
- Open the firmware upgrade tool. Click "Refresh Device", then select the serial port number of the radar module from the "Port Number" dropdown box, with a baud rate of 256000.
- Click "Get Firmware Information" to retrieve the current firmware information and device ID. The HLK-LD2452 firmware has two partitions (APP0 and APP1). If the current firmware is APP0, only APP1 can be selected for download, and vice versa.
- Select the download partition, click "Click to select bin file path", and choose the appropriate .bin file (e.g., HLK-LD2452/APP0.bin or HLK-LD2452/APP1.bin).
- Click "Download" to start the upgrade. The tool will display the real-time download status. A "Download successful!" message indicates completion.
5. Communication Protocol
The HLK-LD2452 module communicates via a serial port (TTL level) with a default baud rate of 256000, 1 stop bit, and no parity check bit.
The radar outputs detected target information including x-coordinate, y-coordinate, and velocity. The data frame format is detailed in the official user manual (PDF).
Figure 8: Hi-Link Enterprise Profile (Factory and Exhibition)
6. Maintenance
To ensure optimal performance and longevity of your HLK-LD2452 module, keep it clean and dry. Avoid exposing it to extreme temperatures or humidity outside its specified operating range. Handle the module with care to prevent physical damage.
7. Troubleshooting
If you encounter issues with your HLK-LD2452 module, consider the following:
- Interference: Ensure there are no constantly moving non-human objects (e.g., animals, swinging curtains, large plants near air vents) within the sensing area. Strong reflection planes or objects facing the radar antenna can also cause interference.
- External Factors: When wall-mounting, consider external interference from air conditioning or electric fans.
- Stability: Ensure the sensor's installation position is firm and stable. Shaking of the radar itself can affect detection accuracy.
- Occlusion: Verify that the radar antenna is directly facing the area to be detected and that the surrounding area is open and unobstructed.
- Back Lobe Interference: Radar waves can penetrate some materials, potentially detecting moving objects behind the radar (back lobe). Use metal shielding covers or backplates to reduce this effect.
- Multiple Radars: If using multiple 24 GHz radars, avoid installing them directly facing each other. Maintain distance to prevent mutual interference.
- Power Supply: Check that the power input is within the specified 3.3V or 5V range and that relevant resistors and capacitors on the circuit board are correctly mounted.
- Software Connection: Ensure the module is correctly connected to the USB serial port tool and that the software detects the device.
- Firmware: If experiencing unexpected behavior, consider upgrading the firmware to the latest version using the provided tool.
8. User Tips
- For optimal performance, ensure a stable and clean power supply to the module.
- Carefully plan the installation location to minimize environmental interference and maximize the detection area.
- Regularly check for firmware updates on the official Hi-Link website to benefit from improvements and new features.
- When experimenting with the software, utilize the data recording feature to analyze target movement patterns and fine-tune settings.
9. Frequently Asked Questions (FAQ)
- Q: What is the maximum detection range of the HLK-LD2452?
- A: The maximum detection range is 6 meters.
- Q: What are the power requirements for the module?
- A: The module can be powered by either 3.3V or 5V. Ensure the correct power supply is used based on your configuration.
- Q: Can the HLK-LD2452 detect multiple targets?
- A: Yes, it can detect and track up to 3 targets simultaneously in multi-target detection mode.
- Q: What are the main applications for this radar module?
- A: It is widely used in AIoT scenarios such as smart homes, offices, and hotels for human presence detection, positioning, and tracking, including smart lighting and intelligent business applications.
10. Support and Resources
For further technical support, inquiries, or detailed documentation, please contact Hi-Link directly.
- Email: ryan@hlktech.com
- Website: www.hlktech.net
- User Manual (PDF): A comprehensive user manual (data sheet) is available for download. You can find it referenced as HLK-LD2452 Data Sheet (PDF).
Figure 9: Hi-Link Contact Information