MYOSLIM Body Sculpt Machine Dual Handles

Contents

Myoslim Body Sculpt Machine User Manual

Dual Handles Non-Invasive Muscle Building & Fat Loss Device

1. General Information

The Myoslim Body Sculpt Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions. This technology promotes muscle growth and reshapes the internal muscle structure. Additionally, the intense muscle contractions trigger significant fat breakdown, releasing fatty acids from triglycerides, which are then metabolized by the body over a few weeks.

Advanced HI-EMT Technology

Achieves intense muscle contractions with high-energy focused electromagnetic waves to promote muscle growth and reshape the deep internal structure.

Touch-Controlled Display

The touch control display significantly simplifies the operation of the device, allowing users to clearly view information from different positions. The screen brightness is adjustable to accommodate various office lighting conditions. The user-friendly screen guides you through the entire treatment process.

Real-time Monitoring and Guidance

Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.

Upgradeability

As your therapeutic needs evolve, the EMSZERO series offers flexible upgrade options to meet your future treatment requirements.

2. Indications for Use

The Myoslim Body Sculpt Machine is intended for:

  • Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
  • Strengthening, toning, and firming of buttocks, thighs, and calves.
  • Improvement of muscle tone and firmness for strengthening muscles in arms.

3. Contraindications

Do not use this device if any of the following conditions apply:

  • Wounds on the skin (or avoid using on wounded areas).
  • Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Major surgery patients, diabetic patients.
  • Having any metal in the body.
  • People with cerebrovascular disease (stroke patients).

4. Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

5. Safety Precautions and Warnings

  • Do not use when feeling full; wait at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Start at the lowest intensity level, and then increase the intensity sequentially according to the user's skin tolerance.
  • It is forbidden to eat or drink during the operation. Try to eat after one hour after the operation.

6. Device Overview and Accessories

Front View of the Instrument

The front panel features the main display screen and the handles attached to their brackets.

Front view of Myoslim device with screen and handles

Image: Front view of the Myoslim Body Sculpt Machine, showing the touch screen and dual handles.

Note: The handle can only be used by the original machine and cannot be used interchangeably.

Rear View of the Instrument

The rear panel includes the screen power switch, ventilation holes, power cord socket, and fuse.

Rear view of Myoslim device showing power switch, fuse, and ventilation

Image: Rear view of the Myoslim Body Sculpt Machine, highlighting the power switch, fuse, and ventilation.

List of Accessories

Serial Name Quantity Picture
1 Host 1 set Myoslim Host Unit
2 Handle 2 Myoslim Handle
3 8*80CM, 8*90CM, 8*100CM belts 3
4 Power cable 1
5 Electronic manual 1 copy

7. Setup (Device Installation)

  1. Install the Handle Bracket

    Need a screwdriver. Install on both sides of the machine. Ensure the handle controller aligns with the hole and fasten the clip. Stick the black film to the working part of the handle.

  2. Connect Power

    Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.

  3. Press the Back Switch

    Move the manual switch on the rear panel to the "o" position to turn on the machine.

  4. Press the Front Switch

    Single-click the front switch to power on. Long press to power off.

Video: Demonstration of connecting the power cord, turning on the machine, and adjusting settings.

8. Operating (Basic Device Operation)

8.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

8.2 Setting the Therapy by Controls

Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

  • Navigation Controls: Access various settings and modes.
  • Channels Selector: Choose between different treatment channels.
  • Stop Therapy: Pause or end the current treatment.
  • Start/Pause Therapy: Begin or temporarily halt the treatment.
  • Setting up Therapy Parameters: Adjust intensity, frequency, and time.
  • Return: Go back to the previous screen.
  • Settings: Access general device settings.

8.3 Unit Settings (Mode 1)

The operation interface of Mode 1 allows you to adjust various details such as machine usage, gender, age, etc. Take out the handle from the handle frame before operation, and use the belt to fix the handle to the operating part required by the customer. The frequency of mode one is 5-60Hz.

Enter the solution interface to adjust the handle operation time according to customer needs, and then click the start/stop button to proceed to the next step.

Adjust the corresponding intensity according to different customer needs to start the operation. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.

8.4 Unit Settings (Mode 2)

The operation interface of Mode 2 allows you to adjust the energy of various machines and can be adjusted according to its own needs. The frequency of mode two is 30-100Hz.

Adjust the corresponding intensity/stage frequency/time according to different customer needs, click the start/pause work button to enter the operation work, if any. When the customer requests to pause, they can click the start/pause work button to pause the work, and after the work is completed, they can directly click the return key to return.

8.5 Handle Alone Work Interface Operation

To use a single handle, pull the intensity of the unused handle to the lowest value. If intensity 1 is at the lowest value, handle B works alone. If intensity 2 is at the lowest value, handle A works alone.

The handle is aligned with the operating part and attached, and then press the start button on the screen to start the operation. Lightly place the handle on the handle holder after use.

8.6 General Settings

Access the settings menu to adjust Language, Sound, Brightness, Date & Time, and System settings. There is also a Technician section for advanced configurations.

9. Therapy Application

9.1 Preparing for Therapy

  1. Communicate with patients.
  2. Ensure good health.
  3. Stay hydrated.
  4. Wear appropriate clothing.
  5. Avoid eating in large quantities.
  6. Familiarize yourself with the treatment process.
  7. Avoid drinking alcohol.

9.2 Placing the Handle

The handles can be placed on various body parts using the provided belts. Ensure the handle is securely attached to the target area.

Handle placement on belly

Belly

Handle placement on buttock

Buttock

Handle placement on arm

Arm

Handle placement on thigh

Thigh

Handle placement on calf

Calf

Handle placement on arse (cushion handle)

Arse (Cushion Handle)

Please operate according to the controller model you have purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer support.

10. Maintenance

10.1 Daily Inspection

Regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.

10.2 Cleaning of the Device Surface

Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents.

10.3 Cleaning of Accessories that Come into Contact with Patient

The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.

10.4 Fuse Replacement

The fuse is set below the handle junction on the back of the machine. An additional spare fuse is included. When replacing the fuse, to prevent electric shock, please turn off the power and unplug the power plug.

10.5 Storage and Transportation

Storage: The instrument should be stored in its original packaging box in a well-ventilated room. The packaging box should be cushioned with padding. The ambient temperature should be controlled between -10°C and 40°C, and the relative humidity should not exceed 93%. It should not be placed in an environment with harmful gases, flammable, explosive substances, or corrosive gases.

Transportation: The instrument in its packaging is suitable for road, rail, air, and water transportation. During loading, unloading, and transportation, it should be protected from severe vibrations and impacts, should not be exposed to moisture, and should not be mixed with flammable or corrosive substances. Specific requirements are detailed in the order contract.

11. Troubleshooting

Fault Phenomenon Causes Exclusions and Workarounds
Device not working
  • The power plug is not inserted into the socket.
  • Power switch not on.
  • Power fuse failure.
  • Check the power.
  • Check the power switch.
  • Replace the fuse.
Handle not working Check the handle for loose connection. Reseat the handle.

12. Specifications (Technical Parameters)

Name Value
Brand Name MYOSLIM
Input Power Supply AC110V-220V 50/60Hz
Output Maximum Power 0-1500W
Frequency 5-200HZ
Screen Size 15 inches
Product Size 54*47*50cm
Net Weight 22.3kg
Material ABS
Certification CE
Cooling System Intelligent air cooling system
Operation Mode Manual Mode + Automatic Mode
Technology Muscle Stimulation, High Intensity Pulsed Electromagnetic
Advantage Body Shape, Muscle Sculpt, Loss Weight

13. Electromagnetic Compatibility

Radiated Electromagnetic Field Immunity Test:

  • Port: Enclosure
  • Basic Standard: IEC 61000-4-3:2020
  • Test Level: 30V/m with 80% AM. 1kHz Modulation
  • Standard Require: A
  • Tester: Sam Liu
  • Temperature: 25°C
  • Humidity: 54%

14. Warranty and Support

14.1 Warranty Card

The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates are provided, and the maintenance fee needs to be charged appropriately. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping out cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year.

Free warranty service is not provided for the following user's failures caused by personal reasons:

  • Faults caused by unauthorized disassembly and modification of this product.
  • Faults caused by accidental fall.
  • Failure caused by lack of reasonable maintenance.
  • Failure to operate according to the correct instructions in the instruction manual.

If you have a problem, need service or other information, please contact our company.

Manufacturer: Guangzhou Xinwei Electronics Technology Co., Ltd.

Manufacturing Address: Room 01, 10th Floor, No. 23 Boyan 2nd Road, Baiyun District, Guangzhou

For a detailed warranty record sheet, please refer to the full PDF manual.

A full user manual in PDF format is available for download: View User Manual (PDF)

15. User Tips

  • Consistency is Key: For best results, adhere to a regular treatment schedule as recommended by the device's modes or a professional.
  • Hydration: Drink plenty of water before and after sessions to support muscle function and overall well-being.
  • Proper Placement: Always ensure the handles are securely and correctly positioned on the target area to maximize effectiveness and prevent discomfort.
  • Start Low, Go Slow: Begin with the lowest intensity setting and gradually increase it as your body adapts to avoid overstimulation or muscle strain.
  • Listen to Your Body: If you experience any unusual discomfort or pain, stop the session immediately and consult the troubleshooting guide or customer support.
  • Cleanliness: Regularly clean the device and handles as instructed to maintain hygiene and prolong the product's lifespan.

16. Update Record

Version Number Update Date Revised Sections/Content
V1.0 July 24, 2025 Initial Release

Note: The update record is used for the revision and update of this product user manual. Our company reserves the right to make changes and upgrades to this manual. No part of this manual may be modified or reproduced by electronic, mechanical, optical, chemical, or manual means without the written consent of our company.