Gaqqee W1209

Contents

W1209 Temperature Controller Instruction Manual

Model: W1209 | Brand: Gaqqee

1. Introduction

This manual provides detailed instructions for the Gaqqee W1209 24V Temperature Controller. This compact and easy-to-use digital thermostat board features a waterproof probe and a digital display, making it suitable for a wide range of household and industrial temperature control applications. Please read this manual carefully before use to ensure proper installation and operation.

2. Key Features

  • Compact and space-saving design.
  • User-friendly interface for easy operation.
  • Durable construction for long service life.
  • High-quality components ensure reliable performance.
  • Wide application range for various temperature control needs.

3. Technical Specifications

ParameterValue
Display TypeRed LED / Blue LED (0.28 inch three-digit digital tube)
Temperature Control Range-50°C to 110°C
Temperature Measurement Accuracy0.1°C
Measurement InputNTC10K/B3950 waterproof sensor
Probe TypeWaterproof probe L=0.3 meters
Output TypeRelay output 10A
Refresh Frequency0.5 seconds
Main Board Power ConsumptionStatic <35mA, Absorption <65mA
Dimensions (L*W*H)49mm * 40mm * 15.8mm
Resolution0.1°C for -9.9°C to 99.9°C, otherwise 1°C
Hysteresis Accuracy0.1°C
High Temperature Protection0°C to 110°C
Input VoltageDC 24V (as per product title and video demonstration)
Weight24g (including packaging)

4. Package Contents

  • W1209 Thermostat Board x 1

5. Safety Precautions

  • Ensure the power supply voltage matches the controller's requirements (DC 24V for this model).
  • Always disconnect power before making any wiring connections or adjustments.
  • Handle the circuit board with care to avoid damage from static electricity or physical impact.
  • Do not exceed the maximum current rating of the relay (10A). For higher loads, use an external contactor.
  • Keep the device away from moisture, extreme temperatures, and corrosive environments.
  • If controlling AC loads (e.g., 220V), ensure proper insulation and safety measures are in place, and consult a qualified electrician if unsure.

6. Setup and Wiring

The W1209 temperature controller requires a DC power supply and connections for the temperature probe and the load to be controlled. The board features a digital display, setting buttons, a sensor interface, a DC power input, and a relay output.

6.1 Component Identification

W1209 Temperature Controller labeled diagram
Figure 1: W1209 Temperature Controller with labeled components.
  • Digital Display: Shows current temperature and settings.
  • SET Button: Enters/exits setting mode, confirms selections.
  • '+' Button: Increases value, navigates menu.
  • '-' Button: Decreases value.
  • Sensor Interface: Connects the NTC waterproof temperature probe.
  • DC Power Input (K1, +12V, GND): Connects to the DC 24V power supply (as shown in video, though some documentation may refer to 12V variants).
  • Relay Output (K0, K1): Switch contacts for controlling the load.

6.2 Basic Wiring (DC Load)

This diagram illustrates connecting the W1209 to a DC 12V power supply and a DC load. Note that the product title specifies 24V, and the video demonstrates a 24V power supply. Ensure your power supply matches your W1209 model's input voltage.

W1209 12V DC Wiring Diagram
Figure 2: Control 12V Wiring Diagram (for DC loads).
  • Connect the DC power supply (e.g., 24V) to the +12V and GND terminals on the board.
  • Connect the temperature probe to the Sensor Interface.
  • For the load, connect one terminal of the load to one of the Relay Output (K0 or K1) terminals.
  • Connect the other Relay Output terminal to the positive (+) terminal of your DC power supply.
  • Connect the negative (-) terminal of your DC power supply to the other terminal of your load.

6.3 Wiring for AC Load (e.g., 220V)

This diagram shows how to wire the W1209 to control an AC 220V load. The W1209 board itself is powered by DC (e.g., 24V), and its relay acts as a switch for the AC circuit.

W1209 220V AC Wiring Diagram
Figure 3: Control 220V Wiring Diagram (for AC loads).
  • Connect the DC power supply (e.g., 24V) to the +12V and GND terminals on the board.
  • Connect the temperature probe to the Sensor Interface.
  • For the AC load, connect the Live wire (Fire wire) from your AC source to one of the Relay Output (K0 or K1) terminals.
  • Connect the other Relay Output terminal to one terminal of your 220V AC load.
  • Connect the Neutral wire from your AC source to the other terminal of your 220V AC load.

6.4 Visual Wiring Demonstration

Watch this video for a step-by-step visual guide on connecting the W1209 temperature controller and its probe.

Play video
Watch video online
Video 1: W1209 Temperature Controller Wiring and Basic Operation.

7. Operating Instructions

7.1 Setting the Desired Temperature

  1. After connecting power and the probe, the display will show the current measured temperature.
  2. Press the SET button once. The temperature display will start flashing.
  3. Use the '+' and '-' buttons to adjust the desired temperature setpoint.
  4. Press the SET button again to confirm the setting, or wait for 10 seconds for the controller to automatically confirm and return to normal operation.

7.2 Parameter Settings (P0-P6)

To access advanced settings, long press the SET button for 5 seconds. The display will show 'P0'. Use the '+' or '-' buttons to cycle through the parameters (P0 to P6). Press SET once to enter a parameter's setting, use '+' or '-' to change its value, and press SET again to confirm. Long press SET or wait 10 seconds to exit the parameter menu.

CodeDescriptionSetting RangeFactory Default
P0Cooling/Heating ModeC (Cooling) / H (Heating)C
P1Hysteresis Setting0.1 - 15°C2°C
P2Highest Setting Limit110°C110°C
P3Lowest Setting Limit-50°C-50°C
P4Temperature Correction-7.0 to 7.0°C0°C
P5Delay Start Time0 - 600 seconds0 seconds
P6High Temperature Alarm0 - 110°COFF

7.3 Display Indicators

  • Indicator Light: Off indicates the relay is open; On indicates the relay is closed.
  • 'LL' on Display: Indicates the sensor is open or disconnected.
  • 'HH' on Display: Indicates the measured temperature is outside the valid range (-50°C to 110°C). The controller will force the relay to disconnect.
  • '---' on Display: Indicates high temperature protection is active.

7.4 Factory Reset

To restore the controller to factory default settings, long press the power button while the device is in the shutdown state.

8. Maintenance

  • Keep the device clean and free from dust. Use a soft, dry cloth for cleaning.
  • Regularly check wiring connections to ensure they are secure.
  • Avoid exposing the device to direct sunlight or extreme heat, which can affect its performance and lifespan.
  • The waterproof probe is designed for immersion, but ensure the main board remains dry.

9. Troubleshooting

ProblemPossible CauseSolution
Display shows 'LL'Sensor is open or disconnected.Check the sensor connection. Ensure it is securely plugged into the sensor interface. Replace sensor if damaged.
Display shows 'HH'Measured temperature is outside the -50°C to 110°C range.Verify the ambient temperature or the temperature being measured is within the operational range. The relay will be forced off for safety.
Display shows '---'High temperature protection is active.This indicates the temperature has exceeded the P6 alarm setting. Allow the temperature to decrease or adjust P6 if necessary.
Controller not powering onIncorrect power supply voltage or wiring.Check that the power supply is DC 24V and correctly connected to the +12V and GND terminals. Verify power supply is functional.
Load not switchingIncorrect wiring, faulty relay, or load issue.Review the wiring diagrams carefully. Ensure the load is functional and within the 10A relay rating. Check if the indicator light changes state when temperature crosses the setpoint.

10. User Tips

  • For precise temperature control, consider the hysteresis (P1) setting. A smaller hysteresis value will result in more frequent switching but tighter control.
  • If the displayed temperature seems inaccurate, use the temperature correction (P4) parameter to calibrate it against a known accurate thermometer.
  • When controlling heating elements, setting a delay start time (P5) can prevent rapid cycling and extend the life of the heating element and relay.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or refer to the product listing on the platform where it was purchased. Keep your purchase receipt as proof of purchase.

You can also refer to the official user manual (PDF) for additional details: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.