MYOSLIM Cryo T Shock Slimming Machine

Contents

MYOSLIM Cryo T Shock Slimming Machine User Manual

Model: Cryo T Shock Slimming Machine | Brand: MYOSLIM

MYOSLIM Cryo T Shock Slimming Machine with various applicators

MYOSLIM Cryo T Shock Slimming Machine, featuring cryo slimming, toning, body contouring, cellulite decrease, and skin tightening functions.

1. Introduction and General Information

The MYOSLIM Cryo T Shock Slimming Machine utilizes advanced HI-EMT (High-Energy Focused Electromagnetic) technology to induce powerful muscle contractions. This process aims to promote muscle growth, reshape internal muscle structure, and facilitate fat breakdown through intense muscle activity. The device is designed for professional use in beauty and wellness settings.

Advanced HI-EMT Technology

This technology employs high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth and deep internal structural reshaping. It also claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

Touch-Controlled Display

The integrated touch-controlled display simplifies device operation, offering clear visibility of information from various positions. The display brightness is adjustable to suit different lighting conditions, providing a user-friendly interface that guides through the treatment process.

Real-time Monitoring and Guidance

During treatment, the display provides real-time information including remaining treatment time, utilized channels, treatment methods, applied treatment types, attachments used, and other essential data. This feature assists users in monitoring treatment progress and provides necessary guidance.

Upgradeability

The EMSZERO series offers flexible upgrade options to meet evolving therapeutic needs and future treatment requirements.

2. Indications for Use

The EMSZERO device is intended for use in:

  1. Improvement of abdominal tone, strengthening of the abdominal muscles, and development of a fitter abdomen.
  2. Strengthening, toning, and firming of buttocks, thighs, and calves.
  3. Improvement of muscle tone and firmness, for strengthening muscles in arms.

3. Operating Environment

Ensuring the correct operating environment is crucial for the effectiveness and safety of the EMSZERO device.

  • Clean and Hygienic Environment: The operating environment must be clean and hygienic to prevent contamination. Regular cleaning and disinfection of the equipment and accessories are essential.
  • Appropriate Temperature and Humidity: Maintain the operating environment's temperature and humidity within the manufacturer's specified range. Extreme conditions can affect device performance.
  • Adequate Lighting: Ensure sufficient lighting for clear visibility and correct operation of the equipment.
  • Good Ventilation: The operating area should have adequate ventilation to ensure air circulation and prevent accumulation of harmful gases.
  • Safety Measures: Implement appropriate safety measures, including fire extinguishers and first aid equipment. Operators should be familiar with safety procedures.
  • Avoidance of Interference Sources: Keep the equipment away from electromagnetic fields or other devices that could cause interference.
  • Operator Training: All operators must undergo proper training on correct usage and safety procedures.

4. Safety Precautions and Warnings

Precautions Before Use:

  • Do not use the device when feeling full; wait at least one hour after meals.
  • Remove all metal jewelry before using the instrument.
  • Before starting operation, touch the probe vertically to the skin, then turn on the main unit switch and adjust the intensity gradually according to the user's skin tolerance, starting from the lowest level.
  • It is forbidden to eat or drink during operation. Wait at least one hour after operation before eating.

Contraindications:

  • Wounds on the skin (or avoid using on wounded areas).
  • Patients with heart disease, especially those with pacemakers or arrhythmias.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Patients undergoing major surgery or diabetic patients.
  • Individuals with any metal in the body.
  • People with cerebrovascular disease (stroke patients).

Possible Side Effects:

These effects may include, but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

5. Device Overview and Accessories

5.1 Front and Rear Panel of the Main Unit

The main unit features a display screen on the front for operation and monitoring. EMS Handles are connected to the unit. The rear panel includes connections for the handles, a power plug, and a fuse. A switch is also located on the rear panel.

Front view of the MYOSLIM Cryo T Shock Slimming Machine

Front view of the EMSzero main unit, showing the display and handle connections.

Rear view of the MYOSLIM Cryo T Shock Slimming Machine

Rear view of the EMSzero main unit, showing power input and handle ports.

5.2 Handles

The device comes with various handles designed for different applications. These include:

  • Standard EMS Handles (typically two units).
  • Cushion-style handles for broader application areas.
  • Round paddle and square paddle static applicators are optional.

Note: The handles are designed for use with the original machine only and are not interchangeable with other devices.

5.3 List of Accessories

The standard package includes:

  • 1 set of the main host unit.
  • 2 Handles (standard type).
  • 1 Cushion handle.
  • 3 belts (8*80CM, 8*90CM, 8*100CM) for securing handles.
  • 1 Power cable.
  • 1 Electronic manual (this document).

6. Device Installation

  1. Install the Handle Bracket: Secure the handle bracket to both sides of the main unit using a screwdriver.
  2. Apply Handle Film: Apply the black film to the working part of each handle.
  3. Install the Handles: Align the handle with the corresponding port on the main unit and fasten the clip. Lock the key ring to secure it.
  4. Connect Power: Connect one end of the power cord to the machine's power input and the other end to a suitable power socket. Ensure the power cord is plugged directly into the main socket and avoid connecting multiple machines to one socket.
  5. Press Back Switch: Press the power switch located on the rear panel to the "o" position (on).
  6. Press Front Switch: Press the power button on the front panel to turn on the device. For power off, long press the front power button.

7. Basic Device Operation

7.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing a handle, always turn off the machine's power. Handles cannot be replaced while the machine is powered on.

7.2 Device Start-up/Shut-down

  1. Connect the power cord as described in the installation section.
  2. Move the manual switch on the rear panel to the "o" position (on).
  3. Press the power button on the front panel.
  4. To shut down, press and hold the power button on the front panel after the treatment is finished.

7.3 Navigation Controls and Unit Settings

The device features a touch screen interface for setting up and controlling therapy parameters. The main interface allows selection of different treatment patterns and adjustment of settings.

Setting the Therapy by Controls: Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays time, temperature, and EMS settings. You can adjust these parameters using the on-screen controls.

Unit Settings: Access the settings menu to adjust language, sound, brightness, set date/time, and access technician-specific options. The system allows for selection of different handle types and adjustment of treatment duration, temperature, and EMS intensity.

For example, in Mode 1, you can select the desired handle (e.g., A handle RF, B handle RF, B handle) and adjust the time, temperature, and EMS intensity. In Mode 2, you can select different handles and adjust parameters across three different periods of frequency.

Note: Always adjust the intensity according to customer needs. If a pause is required, use the start/pause button. After work is completed, you can return to the main menu.

8. Therapy

8.1 Preparing for Therapy

  1. Communicate clearly with patients about the procedure.
  2. Ensure the patient is in good health and has no contraindications.
  3. Ensure the patient is adequately hydrated.
  4. The patient should wear appropriate, comfortable clothing.
  5. Advise the patient to avoid eating large quantities before the session.
  6. Ensure the operator is familiar with the treatment process.
  7. Advise the patient to avoid drinking alcohol before the session.

8.2 Placing the Handle

The handles are designed to be placed on various body parts for targeted treatment. Ensure proper placement and secure attachment using the provided belts for optimal results. Examples of handle placement include:

  • Belly: Handles are placed on the abdominal area.
  • Buttock: Handles are positioned on the gluteal muscles.
  • Arm: Handles are secured around the upper arm.
  • Thigh: Handles are placed on the thigh area.
  • Calf: Handles are positioned on the calf muscles.
  • Arse: Handles are placed on the lower back/upper gluteal region.

Refer to the electronic manual (PDF) for detailed diagrams on handle placement for each body area.

Video demonstrating the operation and application of the Cryo T Shock Slimming Machine, including handle usage and interface navigation.

9. Maintenance

9.1 Daily Inspection

Regularly inspect the instrument and its components. Check for a reliable power socket connection and ensure the power cord is undamaged. Discontinue use immediately if any damage is found.

9.2 Cleaning

  • Surface Cleaning: The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents on painted parts.
  • Accessories Cleaning: Parts that come into contact with the patient's skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak accessories directly in alcohol-based detergent; wipe with pure cotton material.

9.3 Replacing the Fuse

To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.

9.4 Storage and Transportation

  • Storage: Store the instrument in its original packaging box in a well-ventilated room. The packaging box should be padded. Maintain an ambient temperature between -10°C and 40°C, with relative humidity not exceeding 93%. Avoid storing near flammable, explosive, or corrosive gases.
  • Transportation: The instrument, in its packaging, is suitable for road, railway, air, and water transportation. During transit, prevent severe vibration and shock, and protect from moisture. Do not mix with flammable or corrosive substances.

10. Troubleshooting

Fault Phenomenon Causes Exclusions and Workarounds
Device not working
  • Power plug not inserted into socket
  • Power switch not on
  • Power fuse failure
  • Check the power connection
  • Check the power switch
  • Replace the fuse
Handle not working Handle connection is loose Reseat the handle

11. Technical Specifications

Parameter Value
Brand Name MYOSLIM
Item Type Massage & Relaxation
Power Supply Alternating Current
Voltage 50-1000V AC (Available in 110V and 220V options)
Material Stainless Steel, Aluminium, ABS
Origin Mainland China
Certification CE
Training Site Muscle Relex Apparatus, Comprehensive Fitness Exercise, Waist & Abdomen Exercise, ARMS, Belly, Legs, Waist, BODY, Head, Foot, BACK, Hand, Wrist, Hip, Chest, Core
Type of Sports Muscle Relaxation
Features Firming, Weight Loss, Skin Rejuvenation
Type Desktop
Application For Commercial
Target Area Body, Face, Eyes, Neck/Throat, Hands, Legs/Arms, Breast
Heat Temperature 45℃
Cooling Temperature 4℃ to -18℃
Static Applicator Round paddle or Square paddle optional
EMS Frequency 4000Hz
Screen Size 8.0 inches
Machine Color White

Electromagnetic Compatibility (EMC)

The device has been tested for electromagnetic compatibility according to IEC 61000-4-3:2020 standards. The test level was 30V/m with 80% AM, 1kHz Modulation. The test setup involved a 7x4x3 meter chamber with a signal generator, power amplifier, and power antenna, monitored by a camera in a control room. This ensures the device operates without significant electromagnetic interference and is not unduly affected by external electromagnetic fields.

12. Warranty and Support

Warranty Information

  • The main machine is guaranteed for one year from the date of purchase (excluding fragile parts and man-made damage).
  • Accessories have a warranty period of 3 months (excluding man-made damage).
  • Free warranty service is not provided for failures caused by unauthorized disassembly, accidental falls, lack of reasonable maintenance, or failure to operate according to the instructions in this manual.
  • If the instrument requires repair after the warranty period, paid after-sales service will be provided.

For detailed warranty terms and conditions, please refer to the warranty card provided with your purchase.

Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

13. User Tips

To maximize the effectiveness and longevity of your MYOSLIM Cryo T Shock Slimming Machine, consider the following user tips:

  • Consistent Application: For best results in muscle toning and fat reduction, adhere to a consistent treatment schedule as recommended by a professional.
  • Proper Hydration: Ensure adequate hydration before and after sessions to support metabolic processes and overall well-being.
  • Skin Preparation: Always apply the recommended gel or conductive medium to the skin before treatment to ensure optimal contact and energy transmission.
  • Gradual Intensity Increase: Start with lower intensity settings and gradually increase them based on client comfort and tolerance to avoid discomfort or adverse reactions.
  • Regular Cleaning: Maintain strict hygiene by cleaning all handles and the machine surface after each use to prevent contamination and ensure device longevity.