1. General Information
The MYOslim RF NEO Nova 6500W Body Sculpting Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions. This technology aims to promote muscle growth and reshape the internal structure of muscles. Additionally, it is designed to trigger significant fat breakdown through intense muscle contractions, leading to fatty acids being released from triglycerides and metabolized by the body over several weeks.
Indications for Use:
- Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
Operating Environment:
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
2. Safety Precautions and Warnings
Precautions before use:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest intensity level, and then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Wait at least one hour after the operation before eating.
Contraindications:
- Wounds on the skin (or avoiding wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during menstrual period.
- Major surgery patients, diabetic patients.
- Individuals with any metal in the body.
- People with cerebrovascular disease (stroke patients).
Possible Side Effects:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
3. Device and Accessories
Front and Rear Panel Overview:
Note: The handle can only be used with the original machine and cannot be used interchangeably.
List of Accessories:
| Serial | Name | Quantity | Description/Image |
|---|---|---|---|
| 1 | Host Machine | 1 set | Main unit of the EMSzero system. |
| 2 | Handles (Standard) | 2 | Standard treatment handles. |
| Cushion Handle (Optional) | 1 | Pelvic cushion handle for specific treatments.
|
|
| 3 | Belts | 3 | Sizes: 8*80CM, 8*90CM, 8*100CM. |
| 4 | Power Cable | 1 | Standard power cable. |
| 5 | Electronic Manual | 1 copy | Digital user manual. |
4. Device Installation
-
Install the handle bracket:
Use a screwdriver to install the handle brackets on both sides of the machine.
-
Handle film application:
Stick the black film to the working part of the handle.
-
Installing the handle:
Align the hole and fasten the clip. Lock the key ring to secure the handle.
-
Connect power:
Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the same socket.
-
Press the back switch:
Toggle the power switch on the rear panel to the "on" position.
-
Press the front switch:
Single-click the front power button to turn on. Long press to turn off.
5. Basic Device Operation
Handle Exchange:
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
Device Start Up/Shut Down:
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
Navigation Controls and Unit Settings:
The touch-controlled display simplifies device operation. The brightness is adjustable for different lighting conditions. The screen guides you through the treatment process, showing remaining time, channels, methods, and attachments.
Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays the following items and functions:
- Navigation controls
- Channels selector
- Stop therapy
- Start/pause therapy
- Setting up therapy parameters (RF, Energy, Time, Frequencies)
Adjust the corresponding intensity/stage frequency/time according to different customer needs. Click the start/pause button to begin the operation. If a pause is needed, click the start/pause button again. After the work is completed, you can click the return key to go back.
6. Therapy
Preparing the Therapy:
- Communicate with patients.
- Ensure good health.
- Stay hydrated.
- Wear appropriate clothing.
- Avoid eating in large quantities.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol.
Placing the Handle:
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
7. Maintenance
Daily Inspection:
Regularly inspect instruments and components. Check for a reliable connection to the ground and ensure the power cord is not damaged. Discontinue use if any damage is found.
Cleaning:
Instrument cleaning should be performed regularly. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents on painted surfaces. Parts that contact the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak in alcohol-based detergent; wipe with pure cotton material.
Fuse Replacement:
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, turn off the power and unplug the power plug before replacing the fuse.
Storage and Transportation:
The instrument should be stored in its original packaging box, in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, and relative humidity should not exceed 93%. Avoid placing near flammable, explosive, or corrosive gases.
During loading, unloading, and transportation, prevent severe vibration and shock. Protect from moisture. Do not mix with flammable or corrosive substances. Specific requirements are detailed in the order contract.
8. Troubleshooting
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | Power plug not inserted into socket, power switch not on, or power fuse failure. | Check the power connection, check the power switch, replace the fuse. |
| Handle not working | Loose handle connection. | Reseat the handle. |
9. Specifications
| Attribute | Value |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Application | BODY |
| Material | ABS |
| Size | Small |
| Machine Size | 58*77*138 cm |
| Power Supply | Alternating Current |
| Voltage | AC220V/50Hz AC110V/60Hz (50-1000V AC) |
| Power | 0-6500W |
| Frequency | 0-200HZ |
| Handles | 4/5 handles |
| Technology | HIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting |
| Product Name | Body Sculpt Machine, E HIEMT Body Slimming Sculpting Machine |
| Usage Time | Three times a week, 30-40 minutes each time. |
| Certification | CE, RoHS |
| Language Support | English, Spanish, Portuguese, Chinese, French, Russian and other 8 languages |
| Customization Support | Simple logo on the boot interface or fuselage appearance (cannot be infringing trademarks, customized products do not support no reason to return, can only be shipped from China) |
Electromagnetic Compatibility (EMC) Test Setup:
The device has undergone Radiated Electromagnetic Field Immunity Test according to IEC 61000-4-3:2020 standards, with a test level of 30V/m with 80% AM, 1kHz Modulation.
10. Warranty and Support
Warranty Card Information:
- The machine can be replaced with a new one within 7 days from the date of purchase (with receipt) if the appearance is intact.
- The main machine is guaranteed for one year (excluding fragile parts, and other non-warranty scope or expired warranty period).
- Maintenance and updates are available, with appropriate charges for maintenance fees.
- If the instrument is broken and needs repair, the buyer bears the return shipping cost within six months of purchase, and the seller bears the shipping-in cost. After six months, the buyer bears all shipping costs.
- The warranty period for accessories is 3 months (excluding man-made damage).
Free warranty service is NOT provided for failures due to:
- Unauthorized disassembly and modification of the product.
- Accidental falls.
- Lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this instruction manual.
After-sales service:
- Lifelong warranty time.
- 24 hours online service.
- Instructions operation video training.
- Video technical support, online support.
- Dual Repair Centers: Mexico + Europe for faster overseas local after-sales service.
- Professional Technical Team: Experienced engineers support online diagnostics + local repair.
Manufacturer:
Guangzhou Xinwei Electronic Technology Co., Ltd.
11. User Tips
- For optimal results, consistent use of 2-3 times a week is recommended. Visible improvements typically appear after 4-8 weeks.
- Always ensure the handles are securely attached and the power connections are firm before starting any treatment.
- Adjust the intensity gradually, starting from the lowest setting, to find a comfortable yet effective level for your skin tolerance.
- Regular cleaning of the handles and machine surface with a damp cloth is crucial for hygiene and device longevity.
- If you have any questions or encounter issues, utilize the provided 24-hour online service or video technical support.