MYOSLIM EMS Body Sculpt Machine

Contents

MYOSLIM EMS Body Sculpt Machine User Manual

Model: EMS Body Sculpt Machine

Brand: MYOSLIM

1. Introduction

1.1 General Information

The MYOSLIM EMS Body Sculpt machine utilizes advanced High-Intensity Focused Electromagnetic (HI-EMT) technology. This technology employs high-energy focused electromagnetic waves to induce powerful muscle contractions, promoting muscle growth and reshaping the internal structure of muscles. It also triggers significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

The device features a touch-controlled display for simplified operation and clear visibility of information. The display brightness is adjustable to suit various lighting conditions. Throughout the treatment, the display provides real-time monitoring of remaining treatment time, utilized channels, treatment methods, applied treatment types, and attachments used, offering guidance and progress tracking.

The EMS Body Sculpt series offers flexible upgrade options to meet evolving therapeutic needs.

1.2 Indications for Use

The EMS Body Sculpt machine is intended for:

  1. Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
  2. Strengthening, toning, and firming of buttocks, thighs, and calves.
  3. Improvement of muscle tone and firmness, for strengthening muscles in arms.

1.3 Operating Environment

To ensure the effectiveness and safety of the device, maintain the following operating environment:

  • Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent contamination. Regular cleaning and disinfection of the equipment and its accessories are essential.
  • Appropriate Temperature and Humidity: Ensure the environment's temperature and humidity are within the manufacturer's specified range. Extreme conditions may impact performance.
  • Adequate Lighting: Provide sufficient lighting for clear operation and precise procedures.
  • Good Ventilation: The area should have adequate ventilation to ensure air circulation and prevent accumulation of harmful gases.
  • Safety Measures: Have appropriate safety measures, including fire extinguishers and first aid equipment. Operators should be familiar with safety procedures.
  • Avoidance of Interference Sources: Keep the equipment away from electromagnetic fields or other devices that could cause interference.

1.4 Patient Profile

This machine is suitable for adults seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies.

1.5 Contraindications

Do NOT use this device if any of the following apply:

  • Wounds on the skin (or avoid using on wounded areas).
  • Patients with heart disease (e.g., arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, or during menstrual period.
  • Patients who have undergone major surgery or are diabetic.
  • Having any metal in the body.
  • People with cerebrovascular disease (e.g., stroke patients).

1.6 Possible Side Effects

Possible effects may include, but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

2. Safety Precautions and Warnings

Precautions Before Use:

  • Do not use the device when feeling full; wait at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Always start with the intensity at the lowest level, and then gradually increase it according to the user's skin tolerance.
  • It is forbidden to eat or drink during the operation. Try to avoid eating for at least one hour after the operation.

3. Device and Accessories

3.1 Front and Rear Panel of the Main Unit

The main unit features a display screen, EMS handles, and various connection points. Below are diagrams illustrating the front and rear panels.

Front view of MYOSLIM EMS Body Sculpt machine showing display screen and EMS handles.
Front view of the MYOSLIM EMS Body Sculpt machine, highlighting the display screen and EMS handles.
Rear view of MYOSLIM EMS Body Sculpt machine showing handle connections, switch, fuse, and power plug.
Rear view of the MYOSLIM EMS Body Sculpt machine, showing handle connections, switch, fuse, and power plug.

Note: The handle can only be used by the original machine and cannot be used interchangeably.

3.2 Handles and Optional Accessories

The machine comes with various handle configurations. Optional accessories like a cushion are also available.

Different types of EMS handles and an optional cushion accessory.
Various handle types and an optional cushion accessory for the MYOSLIM EMS Body Sculpt machine.

3.3 List of Accessories

The following table details the standard accessories included with the MYOSLIM EMS Body Sculpt machine:

SerialNameQuantityPicture
1Host1 setHost machine
2Handle2EMS Handles
Cushion (optional accessories)1Cushion accessory
3Belt7*100CM*2, 5*60CM*2Belts for securing handles
4Power cable1Power cable
5Electronic manual1 copyElectronic manual icon

4. Device Installation

Follow these steps to install and set up your MYOSLIM EMS Body Sculpt machine:

Diagram showing steps for handle bracket installation, handle film application, handle installation, power connection, and back switch operation.
Detailed steps for device installation.
  1. Install the Handle Bracket: Use a screwdriver to install the handle brackets on both sides of the machine. Ensure installation is successful.
  2. Apply Handle Film: Stick the black film to the working part of the handle.
  3. Install the Handle: Align the hole and fasten the clip. Lock the key ring to secure the handle.
  4. Connect Power: Connect one end of the power cord to the machine and plug the other end into a socket. Plug the power cord directly into the main socket; do not connect multiple machines to one socket.
  5. Press the Back Switch: Locate the switch on the rear panel. Press it to turn the power on (light will illuminate) or off (light will be off).

5. Basic Device Operation

5.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

5.2 Device Start Up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel to start the device.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

5.3 Navigation Controls and Unit Settings

The pre-treatment regimen can be modified via on-screen controls. The treatment interface displays various items and functions:

Screenshot of the MYOSLIM EMS Body Sculpt machine's touch screen interface showing navigation, channels, and therapy parameters.
Treatment interface with navigation controls, channel selectors, and therapy parameters.
  • Navigation Controls: Access different sections like LIST, PATTERN, RECORDS.
  • Channels Selector: Adjust settings for different channels (A, B).
  • Stop Therapy: Button to halt the current treatment.
  • Start/Pause Therapy: Button to begin or temporarily stop the treatment.
  • Setting Up Therapy Parameters: Adjust intensity, time, and frequency.

Mode 1 Operation (5-60Hz):

Screenshot of Mode 1 operation interface on MYOSLIM EMS Body Sculpt machine.
Mode 1 operation interface.

From the Mode 1 interface, adjust the handle operation time according to customer needs. Click the start/stop button to proceed. Adjust intensity based on user tolerance. If a pause is needed, click start/pause. To return after completion, click the back button.

Mode 2 Operation (30-100Hz):

Screenshot of Mode 2 operation interface on MYOSLIM EMS Body Sculpt machine.
Mode 2 operation interface.

Similar to Mode 1, adjust intensity, stage frequency, and time. Use the start/pause button to begin or pause. The interface allows for free adjustment across three different frequency periods.

General Settings:

Screenshots of various settings menus including language, sound, brightness, date/time, system, and technician access.
Various system settings menus.

The device allows for customization of:

  • Language Settings: Select from English, Spanish, Portuguese, French, Russian, Chinese, Japanese, and Korean.
  • Sound Adjustment: Control device audio.
  • Brightness Adjustment: Modify screen brightness.
  • Set Date & Time: Configure the current date and time.
  • System Adjustment: Access general system settings.
  • Technician Access: Password-protected access for technical adjustments.

6. Therapy Application

6.1 Preparing for Therapy

  • Communicate with patients to understand their needs and comfort levels.
  • Ensure the patient is in good health and has no contraindications.
  • Advise the patient to stay hydrated before and after the session.
  • Ensure the patient wears appropriate, comfortable clothing.
  • Advise the patient to avoid eating large quantities before the session.
  • Familiarize yourself with the treatment process and settings.
  • Advise the patient to avoid drinking alcohol before the session.

6.2 Placing the Handle

The handles should be placed securely on the target areas using the provided belts. Refer to the diagrams below for correct placement on various body parts.

EMS handles placed on the abdomen for treatment.
Handles correctly placed on the abdomen.
EMS handles placed on the buttocks for treatment.
Handles correctly placed on the buttocks.
Diagrams illustrating handle placement on various body parts: belly, buttock, arm, thigh, calf, and arse.
Illustrations for handle placement on different body areas.

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.

7. Maintenance

7.1 Daily Inspection

Regularly inspect the instrument and its components. Check that the power socket has a reliable connection to the ground. Before each use, inspect the power cord for any damage. If the power cord is damaged, stop using the instrument immediately.

7.2 Cleaning

Instrument cleaning should be performed regularly to ensure sanitation and proper functioning. The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents on painted surfaces.

Accessories that come into contact with the patient's skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak these accessories directly in alcohol-based detergent; instead, wipe them with pure cotton material.

7.3 Fuse Replacement

The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse.

8. Troubleshooting

Refer to the table below for common issues and their solutions:

Fault PhenomenonCausesExclusions and Workarounds
Device not working
  • Power plug not inserted into socket
  • Power switch not on
  • Power fuse failure
  • Check the power connection
  • Check the power switch
  • Replace the fuse
Handle not workingHandle is looseReseat the handle securely

9. Specifications

9.1 Technical Parameters

ParameterValue
NameE-04
Input Power SupplyAC110V-220V 50/60Hz
Output Maximum Power0-6500W
Frequency5-200HZ
Screen Size8.0 inches
Machine ColorBlack
Tesla15T
ApplicationBODY
MaterialABS
CertificationCE, RoHS
Item TypeMassage & Relaxation
Applicable ScenariosMedical spa, home, gym
FunctionMuscle building, Body sculpt
TheoryElectromagnetic stimulation
Target AreaBody, legs/arms, hands, abdomen, buttocks
After-sales ServiceVideo technical support, online support
Handles2/4/5 handles optional
Package Size58*64*113 cm
Gross Weight77kg
LanguageEnglish, Spanish, Portuguese, French, Russian, Chinese, Japanese, and Korean
Plugs TypeUS, AU, CN, UK, EU
CustomizedLanguage, Startup Logo

9.2 Electromagnetic Compatibility (EMC)

The device has undergone Radiated Electromagnetic Field Immunity Testing according to IEC 61000-4-3:2020 standards.

Test Details:

  • Port: Enclosure
  • Basic Standard: IEC 61000-4-3:2020
  • Test Level: 30V/m with 80% AM, 1kHz Modulation.
  • Standard Requirement: A
  • Temperature: 25°C
  • Humidity: 54%

Test Equipment:

DescriptionManufacturerModelIdentifierCal. DateCal. Due
Signal GeneratorIFA2023BN/A15/03/202214/03/2023
Power AmplifierAR150W1000N/A15/03/202214/03/2023
Power AntennaAR25S1G4AN/A15/03/202214/03/2023

Block Diagram of Test Setup:

Block diagram of the electromagnetic compatibility test setup, showing the 7x4x3 chamber, EUT, power amplifier, signal generator, and control room.
Block diagram of the EMC test setup.

10. Warranty and Support

10.1 Warranty Card

The main machine is guaranteed for one year from the date of purchase (with receipt), excluding fragile parts and other non-warranty scope or expired warranty periods. Accessories have a warranty period of 3 months. Man-made damage is excluded from all warranties.

The company is responsible for maintenance and updates, with appropriate fees charged. If the instrument needs to be sent back for repair within six months of purchase, the buyer bears the return shipping cost, and the seller bears the shipping-in cost. After six months, the buyer bears all shipping costs.

Free warranty service is not provided for failures caused by:

  • Unauthorized disassembly and modification of this product.
  • Accidental fall.
  • Lack of reasonable maintenance.
  • Failure to operate according to the correct instructions in this instruction manual.

For repairs, you must contact the manufacturer directly and not repair it without authorization. Any unpacking without consent will void the warranty.

A detailed user manual (PDF) is available for download here.

10.2 Manufacturer

Guangzhou Xinwei Electronic Technology Co., Ltd.

11. User Tips

  • Always start with a low intensity setting and gradually increase it to find your comfortable and effective level.
  • For optimal muscle building results, consider combining treatments with regular strength training exercises.
  • If your primary goal is fat burning, ensure you complement the treatments with a balanced diet.
  • After each use, clean the electrodes by wiping them with a damp cloth. Avoid using alcohol-based cleaners as they can cause corrosion.
  • The machine is designed for ease of use, making it suitable for home use and can be operated comfortably while lying down.

12. Frequently Asked Questions (FAQ)

Q: How long does it take to see the effect?
A: Results vary by individual. Typically, muscle tightening can be observed in 2-4 weeks (3-5 sessions per week). For fat burning, with a cooperative diet, waist circumference may reduce by 3-5cm in 1-2 months. For muscle building, combining with strength training is recommended for more significant results.
Q: Can this machine replace traditional fitness?
A: It cannot completely replace traditional fitness but is suitable for individuals who lack time for the gym, require muscle activation during rehabilitation, or wish to break through fitness plateaus.
Q: Is EMS harmful to the body?
A: When used by healthy individuals without contraindications (such as pacemakers or epilepsy), it is safe. For pregnant women or those on their menstrual period, it is not recommended for use on the abdomen. Initial use may cause a slight stinging sensation; it is necessary to adapt from low intensity settings.
Q: Who should not use it?
A: Taboo groups include pregnant women, heart patients, individuals with skin damage or inflammation, and patients with malignant tumors or thrombosis.
Q: How long should I use it each time? How often?
A: For beginners, 15-20 minutes per session, 3 times a week. For advanced users, 30 minutes per session, 5 times a week. Avoid overuse to prevent muscle fatigue.
Q: Do I need to apply gel? How to clean?
A: No conductive gel is needed. After use, wipe the electrode with a damp cloth. Avoid using alcohol for cleaning to prevent corrosion.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.