1. General Information
The EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
1.1 Indications for Use
The EMS Body Sculpt is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.4 Description of the Device
EMSZERO enables a simple and effective treatment process that you can easily perform by adjusting the digital energy selection treatment plan or diagnostic procedure. Any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.
2. Safety Precautions and Warnings
1.5 Contraindications
Do not use the device if any of the following apply:
- Wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
Precautions Before Use
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest level, and then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Wait at least one hour after the operation before eating.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
The main unit features a display screen, EMS handles, and an On/OFF button on the front. The rear panel includes connections for the handles and power.


Note: The handle can only be used by the original machine and cannot be used interchangeably.
3.2 Handle Types
The device supports various handle types for different treatment areas:

3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| Cushion (optional accessories) | 1 | ![]() | |
| 3 | Belts (8*80CM, 8*90CM, 8*100CM) | 3 | ![]() |
| 4 | Power cable | 1 | ![]() |
| 5 | Electronic manual | 1 copy |
4. Device Installation
4.1 Install the Handle Bracket
Use a screwdriver to install the handle brackets on both sides of the machine. Ensure they are securely fastened.
4.2 Handle Film Application
Stick the protective film to the working part of the handles.
4.3 Installing the Handle
Align the handle with the hole on the machine and fasten the clip. Lock the key ring to secure the handle.
4.4 Connect Power
Connect one end of the power cord to the machine and the other end to a power socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.
4.5 Power On/Off
- To Power On: Press the manual switch on the rear panel to the 'I' position. Then, single-click the power button on the front panel.
- To Power Off: Long press the power button on the front panel. Confirm shutdown on the screen.
5. Basic Device Operation
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the 'I' position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls & Unit Settings
Pre-treatment regimens can be modified via on-screen controls. The treatment interface displays various items and functions:
- Navigation Controls: Access different menus like List, Pattern, and Records.
- Channels Selector: Choose between different treatment channels (A and B).
- Stop/Start/Pause Therapy: Control the treatment session.
- Setting up Therapy Parameters: Adjust intensity, time, and frequency.
Mode 1 Operation:
- From the main screen, click 'Mode 1'.
- The operation interface for Mode 1 will appear. Ensure handles are properly placed and secured with belts.
- Adjust the handle operation time according to customer needs.
- Click the start/stop button to begin the treatment.
- Adjust intensity as needed. If pausing, click start/pause. To return after work, click the back button.
Mode 2 Operation:
- From the main screen, click 'Mode 2'.
- The operation interface for Mode 2 will appear. Ensure handles are properly placed and secured with belts.
- Adjust the corresponding intensity/stage frequency/time according to customer needs.
- Click the start/pause button to begin the treatment.
- Adjust intensity as needed. If pausing, click start/pause. To return after work, click the back button.
General Settings: The device allows for language settings, sound adjustment, brightness adjustment, setting date and time, and system adjustments. Access these through the 'Set up' icon on the main screen.
6. Therapy
6.1 Preparing for Therapy
- Communicate with patients to understand their needs and comfort levels.
- Ensure the patient is in good health and has no contraindications.
- Ensure the patient is adequately hydrated.
- The patient should wear appropriate, comfortable clothing that allows for proper handle placement.
- Avoid eating large quantities before the session.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol before the session.
6.2 Placing the Handle
Proper placement of the handles is crucial for effective treatment. Refer to the diagrams below for guidance:






Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
7. Maintenance and Repair
7.1 Maintenance
7.1.1 Daily Inspection
Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
7.1.2 Cleaning
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off.
7.1.3 Replacing the Fuse
When replacing the fuse, to prevent electric shock, turn off the power and unplug the power plug. The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included.
7.2 Repair
If the instrument breaks down and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year. After the warranty period has expired, please contact the manufacturer directly to provide paid after-sales service. To repair the machine, you must contact the company's business department or dealer, and do not repair it without authorization. Any unpacking without consent will not be guaranteed by our company.
8.3 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
8.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, the relative humidity should not be greater than 93%, and it is not allowed to be placed near flammable, explosive substances and corrosive gases.
Transportation: The instrument under the packaging condition is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, it should prevent severe vibration and shock, and should not be affected by moisture, and should not be mixed with flammable and corrosive substances. The specific requirements are specified in the order contract.
8.6 Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working |
|
|
| Handle not working | Check the handle for loose connection | Reseat the handle |
9. Technical Parameters
| Attribute | Value |
|---|---|
| Model Name | E-10 |
| Power Supply | AC110V-220V 50/60Hz |
| Output Maximum Power | 0-6500W |
| Frequency | 5-200HZ |
| Screen Size | 10.4 inches |
| Machine Color | Black |
| High-concerned chemical | None |
| Hand Instrument | Yes |
| Electronic | No |
| Voltage | 50-1000V AC |
| Material | ABS |
| Item Type | Massage & Relaxation |
| Style | PORTABLE |
| Warranty | 12 months, 1 Year |
| Quality Assurance | CE, ROHS certificates |
| Our Service | 24 hours online service, Instructions operation video training |
| Application | For Commercial, Beauty Center & Clinic |
| Type | Desktop |
| Material (Body) | ABS+Steel |
| After-sales Service Provided | Free spare parts, Video technical support, Online support |
9.1 Electromagnetic Compatibility (EMC)
The device has undergone Radiated Electromagnetic Field Immunity Test according to IEC 61000-4-3:2020 standards. The test level was 30V/m with 80% AM, 1kHz Modulation. The test setup involved a 7x4x3 meter chamber with EUT & Support, Power Amp, Signal Generator, and EUT Monitoring using a camera in a Contro Room.

10. Warranty and Support
Warranty Card
The main machine is guaranteed for one year (excluding fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates may incur appropriate fees. The warranty requires a warranty card and purchase bill.
Free warranty service is not provided for failures caused by:
- Unauthorized disassembly and modification of this product.
- Accidental fall.
- Lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this instruction manual.
For detailed warranty information, please refer to the User Manual (PDF).
11. Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
User Tips
- Always start with the lowest intensity setting and gradually increase it based on your comfort and tolerance.
- Ensure proper hydration before and after each session to support muscle function and recovery.
- Consistency is key. Regular sessions as recommended in the manual will yield better results.
- Clean the handles and contact areas thoroughly with 75% alcohol before and after each use to maintain hygiene.
- If you experience any unusual discomfort or pain, stop the session immediately and consult a professional.
Frequently Asked Questions (FAQ)
- Q: How long should a typical session last?
- A: The manual indicates a typical session duration of 30 minutes. Adjustments can be made via the control panel.
- Q: Can I use the machine if I have a metal implant?
- A: No, the device is contraindicated for individuals with metal in their body, including pacemakers or other implants.
- Q: What should I do if the machine is not turning on?
- A: First, check if the power plug is securely inserted and if the power switch on the rear panel is in the 'I' position. If it still doesn't work, check the power fuse and replace it if necessary.
- Q: How often should I clean the device?
- A: The device housing should be wiped with a damp cloth, soapy water, or a neutral detergent regularly. Accessories that contact the skin should be cleaned and disinfected with 75% alcohol before and after each use.