1. Important Safety Instructions
Please save these instructions for future use! This manual contains all safety, installation, and operating instructions for the POW-LVM5K Series all-in-one solar charge inverter. Please read all instructions and precautions in the manual carefully before installation and use.
- Non-safety voltage exists inside the all-in-one solar charge inverter. Do not disassemble the inverter yourself. Contact professional maintenance personnel for repairs.
- Do not place the inverter within the reach of children.
- Do not install the inverter in harsh environments such as moist, oily, flammable, explosive, or heavily dusty areas.
- The mains input and AC output are high voltage; do not touch the wiring terminals.
- The housing of the inverter is hot when working. Do not touch it.
- Do not open the terminal protective cover when the inverter is working.
- It is recommended to attach proper fuse or circuit breaker to the outside of the inverter.
- Always disconnect the fuse or circuit breaker near the terminals of PV array, mains, and battery before installing or adjusting wiring.
- After installation, check that all wire connections are tight to avoid heat accumulation.
- The all-in-one solar charge inverter is off-grid. Confirm it is the only input device for load; do not use it in parallel with other input AC power to avoid damage.
2. Product Overview
2.1. Key Features
The POW-LVM5K series is a new type of mixed solar energy storage inverter, integrating solar energy storage, municipal power charge, and AC sine wave output. It features DSP control and advanced algorithms for high response speed and reliability.
- Pure digital voltage and current double closed-loop control with advanced SPWM technology for pure sine wave output.
- Two output modes: mains bypass and inverter output for uninterrupted power supply.
- Four optional charge modes: only solar energy, mains priority, solar energy priority, and mixed charge.
- Advanced MPPT technology with efficiency up to 99.9% and wide MPPT voltage range.
- Lithium battery activation function (solar/AC mains), compatible with lead-acid and lithium batteries.
- LCD screen and 3 LED indicators for dynamic system data display.
- ON/OFF rocker switch for AC output control.
- Power saving mode to reduce no-load loss.
- Intelligent adjustable speed fan for efficient heat dissipation.
- Multiple protection functions: short circuit, overvoltage, undervoltage, overload, back filling.
- Mixed load function: PV and commercial power can supply load simultaneously (without battery) or when battery is full.

Figure 2.1: Key features of the 5000W Off-Grid Solar Inverter, highlighting its pure sine wave output, 80A MPPT controller, maximum PV input of 5500W/500VDC, compatibility with lead-acid and lithium batteries, and support for solar, utility, or generator charging.
2.2. Basic System Introduction
A complete system includes:
- Photovoltaic module: Converts light energy to DC, charges battery, or directly inverts to AC for load.
- Mains or generator: AC input for load supply and battery charging.
- Battery: Ensures normal power consumption when solar/mains supply is insufficient.
- Household load: Various AC loads (refrigerators, lamps, TVs, fans, ACs, etc.).
- Inverting and control all-in-one inverter: The energy conversion device.

Figure 2.2: Illustrates common application scenarios for the hybrid solar inverter, including RV use, home energy storage, camping setups, and integration into larger solar power systems.
2.3. Appliance Compatibility
The inverter is compatible with a variety of daily appliances. Ensure not to overload the unit. Refer to the load selection table for guidance.

Figure 2.3: Displays various appliances compatible with the inverter (TV, Refrigerators, Drill, Air conditioners, Water pump, Washing machines, Laptop, Kettle) and provides a load selection table. The table details load types (Resistive, Inductive, Mixed), load rated power, start impact coefficient, minimum continuous output power, and examples for proper inverter model selection.
3. Setup and Installation
3.1. Installation Notice
- Wear goggles when installing lead-acid liquid batteries. Wash any skin contact with battery acid immediately.
- Do not place metal objects near the battery to prevent short circuits.
- Ensure good ventilation around the battery due to potential acid gas generation during charging.
- Reserve sufficient space around the inverter for heat dissipation. Do not install the inverter and lead-acid liquid battery in the same cabinet.
- Only charge batteries of a consistent type with the inverter.
- Ensure all connections are tight and wires are secured to prevent overheating from loose connections.
- Tie conductors should not exceed $5A/mm^2$ current density.
- Protect outdoor installations from direct sunlight and rain.
- High voltage may remain inside the inverter even after power switch is off. Do not open or touch internal components until capacitors are fully discharged.
- Do not install in humid, greasy, flammable, explosive, or dusty environments.
- Do not reverse battery input polarity.
- AC supply input and AC output are high voltage; do not touch wires.
- Do not touch the fan when operating.
- Confirm the inverter is the sole power supply for the load; do not use in parallel with other AC power sources.
3.2. Mounting the Inverter
Confirm the installation position allows for adequate heat dissipation. Reserve at least 200mm space at the left and right air outlets. Install the unit by screwing two M6 screws into the wall.
3.3. Wiring Instructions
Before connecting all wirings, remove the bottom cover by unscrewing two screws. Observe national and local electrical specifications.
Video 3.1: Step-by-step installation guide for the PowMr Hybrid Solar Inverter. This video demonstrates securing the unit to the wall, removing the terminal cover, connecting the battery, solar array, AC output, AC input, grounding the unit, reattaching the cover, and finally powering on the system.
Wiring Steps from Video:
- Mounting: Secure the inverter to the wall using two screws.
- Access Terminals: Remove the terminal cover by unscrewing two screws.
- Battery Connection: Connect the battery cables to the designated terminals. Ensure correct polarity (red for positive, black for negative). Tighten securely.
- Solar Array Connection: Connect the solar array cables to the PV input terminals. Ensure correct polarity. Tighten securely.
- AC Output Connection: Connect the AC output circuit wires (Load) to the AC OUT terminals (L, N, Ground). Tighten securely.
- AC Input Connection: Connect the AC input circuit wires (Utility/Generator) to the AC IN terminals (L, N, Ground). Tighten securely.
- Grounding: Ground the unit by connecting a ground wire to the designated grounding screw.
- Reattach Cover: Reattach the terminal cover to the inverter by screwing it back in.
Wiring Specifications:
- PV Input: $6mm^2$/10AWG, Max. 22A, 2P-25A breaker.
- AC Input: $10mm^2$/7AWG, Max. 63A, 2P-63A breaker.
- Battery: $30mm^2$/7AWG, Max. 125A discharge, 80A charge, 2P-200A breaker.
- AC Output: $10mm^2$/7AWG, Max. 42A, 63A bypass, 2P-63A breaker.
Note: Use thicker wire for longer distances to reduce voltage drop. Select appropriate wire diameter and breaker based on practical conditions.
3.4. Start-up Procedure
- Close the breaker at the battery end.
- Press the rocker switch on the lower left side to