GEYA GYHC Modular Contactor Manual

Contents

GEYA GYHC Modular Contactor User Manual

Model: GYHC Modular Contactor Manual

Brand: GEYA

1. Product Overview

The GEYA GYHC series of household AC contactors are designed for reliable control in various electrical systems. These modular contactors are primarily used in AC 50Hz (or 60Hz) power systems with rated operating currents up to 63A and rated working voltages up to 250V/400V.

They are suitable for long-distance frequent switching operations under AC-1, AC-7A, and AC-7B usage categories. They can control low-inductance, micro-inductance loads in household appliances and similar applications, and can also manage household motor loads (with appropriate power reduction).

GYHC contactors are available in two versions: with and without manual operation. Their broad scope makes them suitable for a wide range of applications, including:

  • Lighting systems
  • Heating and ventilation systems
  • Roller shutters
  • Public hot water systems
  • Mechanical ventilation systems
  • Load-shedding of non-priority circuits
  • Automobile charging piles
  • Commercial electric boilers

These contactors are commonly found in homes, hotels, apartments, office buildings, hospitals, public buildings, supermarkets, and urban lighting installations.

GEYA GYHC Manual Type Modular Household Contactor
GEYA GYHC Manual Type Modular Household Contactor, highlighting features like eco-friendly silver contacts, imported enameled wire, flame retardant housing, ultra-quiet operation, and compact rail mounting. It also notes a 70% volume reduction and less than 15dB noise.
GEYA Contactor Best Choice
GEYA Contactor, showing 25A and 63A models, 220VAC, and 2P/4P configurations.
GEYA Contactor Widely Applied
Image illustrating wide applications of the GEYA contactor, including local control of industrial equipment, temporary power supply, agricultural irrigation, and new energy fields.

2. Safety Information and Precautions

Please read and understand all safety instructions before installing or operating the contactor. Failure to follow these instructions may result in serious injury or property damage.

General Safety Guidelines

  • Contactors are not designed to break short-circuit current. Always use appropriate short-circuit protection electrical appliances in conjunction with the contactor.
  • This product does not include wireless functionality or a battery.
  • No high-concerned chemicals are present in this product.

Environmental Conditions

  • Ambient Air Temperature: The operating temperature should not exceed +60°C and not be lower than -5°C. If the product is installed inside a power distribution box, thermal insulation parts must be assembled on both sides to facilitate heat dissipation.
  • Altitude: Do not exceed 2000m.
  • Atmospheric Conditions: The relative humidity of the air at the installation site should not exceed 50% when the maximum temperature is +40°C. Higher relative humidity (e.g., 90% at +20°C) is allowed at lower temperatures. Special measures should be taken to prevent occasional condensation due to temperature changes.
  • Pollution Level: Level 2.
  • Installation Category: Level II.
  • Shock and Vibration: Ensure there is no significant shock and vibration at the installation position.

Installation Precautions

  • The installation position must be vertical, with an inclination in any direction not exceeding ±5°.
  • When 2P products are installed too tightly, heat insulation parts must be installed between products to facilitate heat dissipation.
  • If the temperature in the distribution box is too high, the capacity of the contactor may need to be reduced.

3. Specifications

General Product Attributes

AttributeValue
Model NumberGYHC Modular Contactor Manual
Product NameModular Household Contactor
Brand NameGEYA
OriginMainland China
CertificationCE
Electricity TypeAC
OperationAuto or Manual
InstallDin Rail Mounted
Number of Pole2, 4
Phase2
POLE2P, 4P
Contact2NO, 2NC, 4NO
Current25A, 63A

Technical Parameters

ParameterValue
Rated Voltage (Ue)1P,2P: 250V AC; 3P,4P: 400V AC
Frequency50Hz
Service Life (O-C)30000 Times
Max Switching Frequency (per day)100
Isolation Voltage (Ui)500 V AC
Class of Pollution2
Rated Impulse Withstand Voltage (Uimp)2.5kV (4kV @ 12/24/48VAC)
Protection GradeBreaker body: IP20; Installed inside the distribution box: IP40
Operating Temperature-5°C ~ +60°C
Storage Temperature-40°C ~ +70°C
Wet and Heat Resistance (IEC 60068.1)Class 2 (relative humidity is 95% when the temperature is 55°C)
ELSV (extra low safety voltage)Conforms to version 12/24/48VAC
Product control conforms to the requirement of SELVSafety extra low voltage

Rated Current, Control Voltage, and Holding Power (50Hz)

TypeRated Current (In) AC-7aRated Current (In) AC-7bControl Voltage (V AC)Holding Power (W)Inrush Power (VA)
2P Models
2P16A6A12V, 24V, 110V, 220-240V1.3W3.8VA (12/24V), 2.7VA (220-240V)
2P20A7A12V, 24V, 110V, 220-240V1.3W (12/24/110V), 1.2W (220-240V)3.8VA (12/24/110V), 2.7VA (220-240V)
2P25A8.5A12V, 24V, 110V, 220-240V1.3W (12/24/110V), 1.2W (220-240V)3.8VA (12/24/110V), 2.7VA (220-240V)
2P32A12A110V, 220-240V1.6W4.6VA
2P40A15A110V, 220-240V1.6W4.6VA
2P63A20A110V, 220-240V1.6W4.6VA
4P Models
4P16A6A24V, 110V, 220-240V1.6W4.6VA
4P20A7A24V, 110V, 220-240V1.6W4.6VA
4P25A8.5A24V, 110V, 220-240V1.6W4.6VA
4P32A15A24V, 110V, 220-240V2.1W6.5VA
4P40A15A24V, 110V, 220-240V2.1W6.5VA
4P63A20A24V, 110V, 220-240V2.1W6.5VA

Dimensions and Pole Configurations

Number of PolesBreadth (mm)Rated Current In (A)Rated Control Power Supply Voltage Us (V)Contact Configuration
1P1816A/20A/25AAC24V AC110V AC230V1NO, 1NC
2P1816A/20A/25AAC24V AC110V AC230V2NO, 2NC, 1NO1NC
3P3632A/40A/63AAC24V AC110V AC230V3NO, 3NC
4P5432A/40A/63AAC24V AC110V AC230V4NO, 4NC, 2NO2NC, 3NO1NC

Package Dimensions

  • Length: 19 cm
  • Width: 12 cm
  • Height: 6 cm
  • Weight: 0.267 kg
Dimensional drawings for 25A and 40/63A Manually Operated Contactors
Dimensional drawings for Manually Operated Contactors (25A and 40/63A models), showing height, width, and depth measurements in millimeters.

4. Setup and Installation

The GEYA GYHC Modular Contactor is designed for Din Rail mounting (standard 35mm guide rail). Ensure the installation surface is stable and free from significant shock or vibration.

Wiring Instructions

Refer to the wiring diagrams and table below for correct connections. Always ensure power is disconnected before performing any wiring.

Video demonstrating the wiring process for the GEYA GYHC contactor, connecting it to a power supply and a load (light bulb).
TypeRated CurrentStripping LengthCircuitTorqueCopper Line (Hard Line)Copper Line (Flexible Line or Haze Line Terminal)
GYHC PZ1.4mm16-100A9mmControl Loop0.8Nm1.5~2.5mm²1.5~2.5mm²
GYHC PZ1.4mm16&25A9mmPower Loop3.5Nm1.5 x 6mm²1 x 4mm²
GYHC PZ2.6mm40A-63A14mmPower Loop3.5Nm6 x 2.5mm²6 x 16mm²
GYHC PZ2.6mm100A14mmPower Loop3.5Nm6 x 3.5mm²6 x 25mm²
GYHCS, GYHCC PZ1.4mm-9mm-0.8Nm2 x 0.5~1.5mm²2 x 0.5~1.5mm²
GYHC24Power supply (N/P) Input (Y1/Y2)--1Nm0.5~10mm² 2x0.5~2x2.5mm²0.5~6mm² 2x0.5~2x2.5mm²
Ti24 ConnectorSpring clamp terminal---1x0.5~1.5mm²1x0.5~1.5mm²
Wiring diagrams for GYHC contactors and terminal types
Detailed wiring diagrams for various GYHC contactor types, including terminal connections and recommended wire sizes.

Accessory Installation (Heat Insulation)

The new heat insulation accessory is easy to install, saving space and improving heat dissipation. When installing 2P products too closely, heat insulation parts must be installed between them to facilitate proper heat dissipation. If the distribution box temperature is too high, the contactor's capacity may need to be reduced.

Heat insulation installation diagram
Diagram showing the installation of heat insulation parts between contactors, with dimensions of 18mm width and 6mm thickness.

5. Operating Instructions

The GEYA GYHC Modular Contactor offers both automatic and manual control modes. The manual control lever allows you to override automatic operation when needed.

Manual Control Operation

The manual control lever has four positions:

  1. Position O (Manual Turn Off): Moves the handle down to the normally closed state, manually turning off the contactor.
  2. Position Auto (Automatic Operation): In this mode, the product automatically controls the on/off status based on the control circuit. When disconnecting the power supply in the normally open state, the product will automatically return to this mode.
  3. Position I (Manual Turn On): Moves the handle upwards to the normally open position, manually turning on the contactor.
  4. Position I+P (Manual Permanent Turn On): This position allows for a manual permanent turn-on.
Operation (Manually Operated Contactor) diagram
Diagram illustrating the four operational positions (O, Auto, I, I+P) of the manual control lever on the contactor, along with their corresponding circuit states.
Video demonstrating the manual and automatic operation of the contactor, showing how to switch between states and its automatic return to auto mode upon power disconnection.

6. Maintenance

To ensure optimal performance and longevity of your GEYA GYHC Modular Contactor, follow these maintenance guidelines:

  • Regular Inspection: Periodically inspect the contactor for any signs of physical damage, loose connections, or excessive dust accumulation.
  • Cleaning: Keep the contactor clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
  • Terminal Tightness: Check all terminal connections periodically to ensure they are securely tightened. Loose connections can lead to overheating and malfunction.
  • Operational Check: Occasionally test the manual operation (if applicable) to ensure the lever moves freely and the contactor switches states correctly.
  • Environmental Control: Ensure the operating environment adheres to the specified temperature and humidity ranges to prevent premature wear or failure.

7. Troubleshooting

If you encounter issues with your GEYA GYHC Modular Contactor, consider the following common troubleshooting steps:

  • Contactor Not Engaging/Disengaging:
    • Check the control voltage supply to terminals A1 and A2. Ensure it matches the rated control voltage.
    • Verify that all wiring connections are secure and correct according to the installation diagrams.
    • If in manual mode, ensure the lever is moved fully to the desired position (I for ON, O for OFF).
    • If in automatic mode, check the external control circuit for proper signaling.
  • Overheating:
    • Ensure the contactor is not overloaded beyond its rated current.
    • Check for loose terminal connections.
    • Verify that adequate ventilation is provided, especially if installed in an enclosed distribution box. Consider adding heat insulation parts if 2P products are installed tightly together.
  • Unusual Noise:
    • A slight clicking sound during switching is normal. However, if there is excessive or continuous buzzing, check the control voltage for stability.
    • Ensure the contactor is securely mounted to the DIN rail.
  • Product Not Returning to Automatic Mode:
    • If the product was manually set to an open state and power was disconnected, it should automatically return to automatic mode upon power restoration. If not, check the manual lever mechanism for any obstruction.

For persistent issues, consult a qualified electrician or contact GEYA customer support.

8. User Tips

  • Normal Switching Sound: The contactor produces an audible click when switching on or off. This is a normal characteristic of the device and indicates proper operation.
  • Verify Connections: Always double-check all wiring connections before applying power to ensure secure and correct installation.

9. Warranty and Support

For detailed warranty information and customer support, please refer to the official GEYA website or contact your local distributor. You may also find additional resources and a user manual in PDF format at the following link: User Manual (PDF).

© 2024 GEYA. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.