1. Introduction
This manual provides essential information for the safe and efficient operation of your KUAIQU R-SPS Series DC Power Supply. The R-SPS series offers high-voltage, wide-range output with precision control, featuring models up to 1000V 1A 1000W. It is designed for various applications including school teaching, laboratory research, and industrial use. Please read this manual thoroughly before using the device.
2. Safety Instructions
To ensure safe operation and prevent damage to the device or injury to yourself, please observe the following safety precautions:
- Always connect the power supply to a grounded outlet.
- Do not operate the device in wet or damp conditions.
- Ensure proper ventilation to prevent overheating.
- Do not open the casing; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
- Verify correct voltage and current settings before connecting any load.
- Avoid short circuits at the output terminals.
- Disconnect power before making or changing connections.
3. Package Contents
Upon unpacking, please verify that all items are present and in good condition:
- KUAIQU R-SPS Series DC Power Supply Unit
- U-shaped output cable (1x)
- Power cable (1x)
- User Manual (this document)
4. Product Overview
The KUAIQU R-SPS Series DC Power Supply features a clear digital display and intuitive controls for precise voltage and current regulation. It incorporates multiple protection mechanisms to safeguard both the device and the connected load.
4.1. Panel Description
- Output Voltage Display
- Output Current Display
- Output Power Display
- Constant Voltage Indicator (C.V)
- Constant Current Indicator (C.C)
- Power Switch
- Current Encoder Knob (Press down to select cursor position)
- Voltage Encoder Knob (Press down to select cursor position)
- Positive Polarity Output Terminal (Red)
- Negative Polarity Output Terminal (Black)
- Grounding Terminal (Green)
- LOCK Button (Press and hold for 5 seconds to activate/deactivate buzzer, short press to lock/unlock output value)
- Memory Recall/Save Buttons (M1, M2, M3)
- OVP (Over Voltage Protection) Button
- OCP (Over Current Protection) Button
- OUTPUT On/Off Button
- Intelligent Cooling Fan (Rear)
- Power Socket (Rear)
- Fuse Box (Rear)
- USB Port (Optional)
- RS-485 Port (Optional)
- RS-232 Port (Optional)
4.2. Key Features
- High-Voltage Output: 0-1000V (model dependent)
- Complete Protection: OCP / OVP / Short-Circuit / Over-Temperature Protection
- 3 Memory Groups: One-touch recall for multiple test scenarios (M1, M2, M3)
- LOCK Function: One-key lock to prevent misoperation
- Smart Control: Precise Voltage/Current Adjustment with Clear Display & Quick Keys
5. Setup
5.1. Initial Inspection
Before first use, gently peel off any protective film from the display panel for optimal clarity.
5.2. Power Connection
- Ensure the power switch is in the OFF position.
- Connect the provided power cable to the power socket on the rear panel of the power supply.
- Plug the other end of the power cable into a suitable grounded AC outlet (110V or 220V, depending on your model and region).
5.3. Load Connection
Connect your load to the output terminals:
- Connect the positive (+) terminal of your load to the red output terminal (9).
- Connect the negative (-) terminal of your load to the black output terminal (10).
- For loads below 5A, use the front terminals. For loads above 5A, use the rear terminals (if available and appropriate for your model).
- Optionally, connect the green grounding terminal (11) to the ground of your setup for enhanced safety.
6. Operating Instructions
6.1. Power On/Off
- To power on, press the "POWER" button (6). The screen will display the previous voltage and current values.
- To power off, press the "POWER" button again.
6.2. Setting Voltage
- Rotate the "VOLTAGE" encoder knob (8) to adjust the voltage.
- When entering the voltage setting, the current digit being set will blink.
- Rotate clockwise to increase the value and counter-clockwise to decrease it.
- Press the encoder knob to move the cursor position.
- Blinking stops after 5 seconds of inactivity, completing the voltage setting.
6.3. Setting Current
- Rotate the "CURRENT" encoder knob (7) to adjust the current.
- When entering the current setting, the current digit being set will blink.
- Rotate clockwise to increase the value and counter-clockwise to decrease it.
- Press the encoder knob to move the cursor position.
- Blinking stops after 5 seconds of inactivity, completing the current setting.
6.4. Storage Setting (M1, M2, M3)
The power supply can store three sets of voltage and current data (M1, M2, M3).
- To recall stored data: Press the corresponding "M1", "M2", or "M3" button (13).
- To store/update data: Adjust the desired voltage and current values. Then, press the corresponding storage button (M1, M2, or M3) again to save the new data. The LED light on the button indicates active memory.
6.5. OCP (Over Current Protection)
OCP protects the load and power supply from overcurrent conditions.
- Short press the "OCP" button (15) to enable or disable the OCP function.
- To set the OCP limit: Press and hold the "OCP" button for 3 seconds to enter the OCP setting state. Use the current adjustment knob to set the desired current limit.
- When OCP is enabled and an external load short circuit or overcurrent occurs, an alarm will sound, and the machine will stop outputting.
- To clear the OCP alarm, short press the "OUTPUT" button (16).
6.6. OVP (Over Voltage Protection)
OVP protects the load and power supply from overvoltage conditions.
- Short press the "OVP" button (14) to enable or disable the OVP function.
- To set the OVP limit: Press and hold the "OVP" button for 3 seconds to enter the OVP setting state. Use the voltage adjustment knob to set the desired voltage limit.
- When OVP is enabled and the load voltage exceeds the set voltage, the machine will stop outputting and issue an alarm.
- To clear the OVP alarm, short press the "OUTPUT" button (16).
6.7. LOCK Function
The LOCK function prevents accidental changes to settings.
- Short press the "LOCK" button (12) to lock the screen buttons.
- Short press the "LOCK" button again to unlock the screen buttons.
- Press and hold the "LOCK" button for 5 seconds to turn on or off the buzzer.
6.8. OUTPUT On/Off
Short press the "OUTPUT" button (16) to switch the power supply output on or off. This helps to avoid accidental damage to the load due to voltage and current changes during setup.
7. Maintenance
7.1. Cleaning
- Regularly clean the exterior of the power supply with a soft, dry cloth.
- Do not use abrasive cleaners or solvents.
- Ensure the ventilation openings and cooling fan (17) are free from dust and obstructions.
7.2. Fuse Replacement
If the power supply does not turn on, the fuse (19) may need replacement. Ensure the device is unplugged from the mains before attempting to replace the fuse. Use only fuses of the specified type and rating (refer to specifications table for details).
8. Troubleshooting
This section addresses common issues you might encounter with your power supply.
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | No power from outlet; Blown fuse; Power cable not connected. | Check power outlet; Replace fuse (see 7.2); Ensure power cable is securely connected. |
| OCP/OVP alarm sounds and output disconnects | Output current/voltage exceeded set limit; Short circuit. | Check load for short circuits or excessive demand; Adjust OCP/OVP limits if necessary; Press OUTPUT button to clear alarm. |
| Output values cannot be adjusted | LOCK function is active. | Short press the LOCK button to unlock the controls. |
| Cooling fan not operating | Device is not under sufficient load/temperature to activate fan. | The intelligent cooling fan operates automatically based on internal temperature. This is normal operation. |
9. Specifications
| Feature | Description |
|---|---|
| Brand Name | KUAIQU |
| Type | Power Supply |
| Use | Other (Lab, School, Research) |
| Output Type | SINGLE |
| Output Power | >500W (up to 1000W for some models) |
| Rated Capacity | >1000VA |
| Output Current | 0-1A (model dependent, some models up to 80A) |
| Output Frequency | 50Hz or 60Hz |
| Input Voltage | 220V±10% 50Hz (110V±10% 60Hz) |
| EU LVD Voltage | Low voltage: Below 50Vac or 75Vdc |
| Display Resolution (Voltage) | 0.01V |
| Display Resolution (Current) | 0.01A |
| Product Dimension | Length 310mm, Width 190mm, Height 86mm |
| Product Weight | 2.2 Kg (approx. 3.5 Kg packaged) |
| Certification | CE, FCC, RoHS |
| Origin | Mainland China |
9.1. Model Specific Output Ranges
| Model | Output Voltage (V) | Output Current (A) | Fuse (110V Input) | Fuse (220V Input) |
|---|---|---|---|---|
| R-SPS3020S | 0-30V | 0-20A | 8A | 5A |
| R-SPS3030S | 0-30V | 0-30A | 12A | 8A |
| R-SPS6010S | 0-60V | 0-10A | 8A | 5A |
| R-SPS6020S | 0-60V | 0-20A | 12A | 8A |
| R-SPS1520S | 0-15V | 0-20A | 5A | 3A |
| R-SPS1530S | 0-15V | 0-30A | 8A | 5A |
| R-SPS1540S | 0-15V | 0-40A | 8A | 5A |
| R-SPS1560S | 0-15V | 0-60A | 12A | 8A |
| R-SPS1005S | 0-100V | 0-5A | 8A | 5A |
| R-SPS1505S | 0-150V | 0-5A | 12A | 8A |
| R-SPS2005S | 0-200V | 0-5A | 15A | 10A |
| R-SPS3040S | 0-30V | 0-40A | 15A | 10A |
| R-SPS10010S | 0-100V | 0-10A | 15A | 10A |
| R-SPS11010S | 0-110V | 0-10A | 15A | 10A |
| R-SPS12010S | 0-120V | 0-10A | 15A | 10A |
| R-SPS2003S | 0-200V | 0-3A | 8A | 5A |
| R-SPS4001S | 0-400V | 0-1A | 8A | 5A |
| R-SPS4002S | 0-400V | 0-2A | 8A | 5A |
| R-SPS6001S | 0-600V | 0-1A | 8A | 5A |
| R-SPS6002S | 0-600V | 0-2A | 12A | 8A |
| R-SPS8001S | 0-800V | 0-1A | 12A | 8A |
| R-SPS2005S | 0-200V | 0-5A | 12A | 8A |
| R-SPS1580S | 0-15V | 0-80A | 12A | 8A |
Note: The table above lists basic models. Models with USB or RS-485 ports will have "-USB" or "-485" appended to the model name (e.g., R-SPS3020S-USB). Refer to the upper computer connection manual for port connections.
10. User Tips
- When adjusting voltage or current, press down on the respective encoder knob to select the digit you wish to change, allowing for finer adjustments.
- Utilize the M1, M2, M3 memory buttons to quickly switch between frequently used voltage/current settings for different projects.
- Always set OCP and OVP limits slightly above your expected operating values to provide a safety margin without triggering false alarms.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact the seller or refer to the product listing where you purchased the device. Keep your purchase receipt as proof of purchase.
A PDF version of the user manual is available for download: User Manual (PDF)