1. Safety Information
Please read this manual thoroughly before operating the device. Keep this manual for future reference.
- Ensure the device is connected to a power source matching the specified voltage (110V or 220V AC).
- Do not operate the device with wet hands or in damp environments.
- Keep the device away from water and heat sources.
- Always use the device with the recommended specialized lubricant to ensure smooth operation and stable energy transmission.
- Do not attempt to open or repair the device yourself. Contact qualified service personnel for any maintenance or repair needs.
- This device is intended for professional use. Ensure proper training before operation.
- Always perform a system check before each use.
- In case of any discomfort during treatment, stop immediately.
2. Product Overview
The MYOSLIM Pro 3 Handles Micro Wave machine is a versatile device designed for various body shaping and skin treatment applications. It features a main unit with a touchscreen interface and multiple handles for different treatment areas.
Key Functions:
- Wrinkle removal
- Body slimming
- Cellulite reduction
- Skin tightening
Components:
- Main Unit with Touchscreen Display
- Three Treatment Handles (Facial, Body, Limb types)
- Power Cable
- Water Inlet/Outlet (for cooling system)
Figure 2.1: Overall view of the MYOSLIM Pro 3 Handles Micro Wave Machine.
Figure 2.2: Key functions of the Cold Wave Shaping Instrument.
Figure 2.3: Close-up view of the three treatment handles.
3. Setup Instructions
- **Unpacking**: Carefully remove all components from the packaging.
- **Placement**: Place the main unit on a stable, flat surface with adequate ventilation.
- **Handle Connection**: Connect the three treatment handles to their respective ports on the main unit. Ensure they are securely fastened.
- **Water Filling**: Locate the water inlet and outlet ports on the back of the machine. Fill the cooling system with distilled water until the water level indicator shows it is full. (Refer to Figure 3.1 for port locations).
- **Power Connection**: Connect the power cable to the machine and then to a grounded electrical outlet (110V or 220V AC, depending on your model).
- **Initial Power-On**: Press the main power switch. The screen will display "WELCOME" followed by a "SYSTEM CHECK". Press "OK" to proceed.
Figure 3.1: Back view of the machine with power and water connections.
Video 3.1: Introduction and basic operation of the cold microwave machine, including power-on sequence and interface navigation.
4. Operating Instructions
- **Select Treatment Type**: On the touchscreen, select the desired treatment from options like "Localized Fat", "Cellulite", or "Tightening".
- **Select Body Part**: Choose the specific body area to be treated (e.g., Stomach, Thighs, Face).
- **Adjust Skinfold Thickness (for fat reduction)**: If performing fat reduction, adjust the skinfold thickness in centimeters on the screen. (Refer to Figure 4.1).
- **Adjust Freezing Level (for fat reduction)**: Adjust the freezing temperature according to the treatment protocol and client comfort. (Refer to Figure 4.2).
- **Choose Handle**: Select the appropriate handle type (facial, body, or limb) for the chosen treatment area.
- **Adjust Energy Parameters**: Adjust the power (in Watts) and dose (in Joules) as required. The normal power setting is 120 Watts. (Refer to Figure 4.3).
- **Safety Mechanism**: To activate the handle, first click "Start" on the screen. Then, turn the handle to open its safety mechanism. This typically involves pressing a button and rotating a part of the handle. (Refer to Video 3.1 for demonstration).
- **Apply Treatment**: Apply a specialized lubricant with thermal conductivity to the treatment area. Place the activated handle on the skin and move it in circular motions. You should be able to feel the heat clearly.
- **Start Emission**: Press the "Emission" button on the screen to begin the treatment.
Figure 4.1: Touchscreen interface for treatment and body part selection.
Figure 4.2: Adjusting freezing level and power on the touchscreen.
Figure 4.3: Proper application of the treatment handle on the body.
5. Maintenance
- **Cleaning**: After each use, wipe down the main unit and treatment handles with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- **Water System**: Regularly check the water level in the cooling system. Replenish with distilled water as needed. It is recommended to drain and refill the water system periodically (e.g., every 3-6 months) to prevent algae buildup and ensure optimal cooling performance.
- **Storage**: When not in use, store the machine in a clean, dry environment, away from direct sunlight and extreme temperatures. Ensure all handles are properly placed in their holders.
- **Inspection**: Periodically inspect the power cable and handle connections for any signs of wear or damage.
6. Troubleshooting
Common Issues:
- **Device not powering on**: Check the power cable connection and ensure the main power switch is on. Verify the electrical outlet is functioning.
- **Handles not activating**: Ensure the safety mechanism on the handle is correctly engaged after pressing "Start" on the screen. Check if the handle is properly connected to the main unit.
- **No heat or cold sensation**: Verify that the power and freezing level settings are correctly adjusted on the screen. Ensure sufficient lubricant is applied to the skin.
- **Error message on screen**: Note down the error code or message and consult the comprehensive user manual (PDF) or contact customer support.
7. Specifications
| Feature | Description |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Function | Hot & Cold Massager, Vibration Massage, Skin Rejuvenation, Skin Tightening |
| Power Source | Alternating Current (AC) |
| Voltage Options | 110V, 220V |
| Plug Type Options | US Plug, EU Plug, UK Plug, AU Plug |
| Type | 3 in 1 (referring to handles/functions) |
| Material | Metal, ABS |
| Batteries Included | No |
| High-concerned chemical | None |
| Hand Instrument | Yes |
| Package Dimensions (L x W x H) | 112 x 88 x 98 cm (approximate) |
| Package Weight | 85.0 kg (approximate) |
Figure 7.1: Certificate of Compliance (DST2613020013SC).
8. User Tips
- **Lubricant Choice**: Always use a specialized lubricant with thermal conductivity. This ensures the probe glides smoothly over the skin and guarantees stable energy transmission for effective treatment.
- **Professional Use**: This machine is well-suited for beauty salons due to its powerful and user-friendly nature.
- **Pre-shipment Checks**: Some sellers provide machine testing videos before shipping, which can offer peace of mind regarding functionality.
- **Communication**: Maintain good communication with your supplier for any questions or support needed, as many users report excellent seller support.
9. Warranty and Support
For detailed warranty information, service, and technical support, please refer to the comprehensive user manual provided in PDF format: User manual (PDF). You may also contact your seller or distributor for assistance.