Gaqqee CY-189

Contents

Gaqqee Carbon Monoxide Detector User Manual

Model: CY-189

Introduction

Thank you for purchasing the CY-189 Carbon Monoxide (CO) alarm. This is a single-station alarm designed to detect carbon monoxide gas. Please take a few minutes to thoroughly read this user's guide and save it for future reference to ensure proper operation and safety.

Carbon Monoxide Detector with LCD Screen Display
The Carbon Monoxide Detector features an LCD screen for clear gas concentration readings.

Features and Specifications

Features:

  • LCD display with a blue backlight for clear readings.
  • Loud 85 dB alarm for effective warning.
  • Equipped with a permanent carbon monoxide sensor.
  • Powered by 3 x 1.5V AA batteries (not included by default).
  • Alarm sound pattern: Four short alarm beeps, accompanied by a flashing red LED.
  • Low battery indication: A single 'chirp' every 30 seconds, with the green LED flashing.
  • Malfunction indication: Green LED is out.
  • Alarm memory feature: If the unit alarms, pressing the button will show the peak alarm level on the LCD, and the green LED will flash once per second for one minute.
  • Test/Reset button: Used to test unit electronics and verify proper operation, and to reset the unit during a CO alarm.
  • 3-digit LCD display: Shows 'Er' for malfunction, 'Lb' for low battery, '999ppm' for CO levels over 999ppm, or the actual concentration if between 30ppm and 999ppm.
  • Power saving feature: Alarm sound pattern changes from 4 beeps every 5 seconds to 4 beeps every minute after 4 minutes to conserve battery.

Specifications:

Parameter Value
Power Supply 3 x 1.5V AA batteries
Sensitivity & Time (50ppm) Alarms within 60-90 minutes
Sensitivity & Time (100ppm) Alarms within 10-40 minutes
Sensitivity & Time (300ppm) Alarms within 3 minutes
Standby Current (no LCD) <50µA
Standby Current (with LCD) <200µA
Alarm Current <75mA
Operation Ambient Condition 5-40°C, 20-90% R.H.
Product Dimensions 98mm x 98mm x 35mm
Color Box Packaging Dimensions 100mm x 100mm x 40mm
Gas Type Detected Carbon Monoxide (CO)
Measurement Range 0-999PPM
Certification CE
Product box and specifications table for Model 602 Carbon Monoxide Detector
Product packaging and detailed specifications for Model 602 (Carbon Monoxide).
Dimensions of the Carbon Monoxide Detector
Physical dimensions of the detector: 98mm x 98mm.

Setup and Installation

Installation Guide:

IMPORTANT: THIS ALARM MUST BE MOUNTED ON A WALL. INSTALL ONLY AS DETAILED!

For maximum protection, install an alarm on each level of a multi-level home, including every bedroom, hallway, finished attic, and basement. Place alarms at both ends of bedroom hallways or large rooms if they are more than 30ft (9.1m) long. If you have only one alarm, ensure it is placed in the hallway outside of the main sleeping area or in the main bedroom. Verify the alarm can be heard in all sleeping areas.

Locate an alarm in every room where someone sleeps with the door closed. Ceiling mounting in the center of the room is preferred. When mounting on the ceiling, locate it at a minimum of 4 inches (10cm) from the side wall. If installing on the wall, mount it at a minimum of 4 inches (10cm) and a maximum of 12 inches (30.5cm) below the ceiling.

(Note: A diagram illustrating ceiling and wall mounting is typically provided in the physical manual, showing acceptable and unacceptable zones for placement relative to walls and ceilings.)

B. When Not to Install:

DO NOT INSTALL IN GARAGES, KITCHENS, FURNACE ROOMS, OR BATHROOMS! INSTALL AT LEAST 15 FEET AWAY FROM ANY FUEL BURNING APPLIANCE.

Avoid installing within 3ft (0.9m) of the following:

  • Doors to kitchens or bathrooms that contain a tub or shower.
  • Forced air ducts used for heating or cooling.
  • Ceiling or whole house ventilating fans, or other high airflow areas.
  • Excessively dusty, dirty, or greasy areas.
  • Areas where drapes or other objects will block the sensor.
  • Peaks of vaulted ceilings, A-frame ceilings, or gabled roofs.
  • Damp and humid areas.
  • Within one foot of fluorescent lights.
  • Areas where the temperature is colder than 40°F (4.4°C) or hotter than 100°F (37.8°C).
  • Near doors and windows that open to the outside.

Step 2: Mounting Instructions:

  1. Remove the mounting bracket from the back of the alarm by twisting the alarm.
  2. After selecting the proper location, drill two Ø5.0mm holes in the ceiling or wall vertically with a distance of 60mm between them.
  3. Insert one plastic insert into each hole, then attach the bracket to the plastic inserts with the arrow pointing down to the ground, and screw tightly.
  4. Match the arrow on the back of the alarm with the arrow on the bracket to snap the alarm onto the bracket by twisting.
Front and back view of the Carbon Monoxide Detector, showing battery compartment
Front and back view of the detector, illustrating the battery compartment and mounting points.
Internal view of battery compartment and sensor details
Detailed view of the durable carbon monoxide probe and battery compartment (3x 1.5V AA batteries).
Package contents including manual, detector, and mounting screws
Contents of the package: Carbon Monoxide Detector, user manual, and mounting screws.

Operation Instructions

Step 3: Testing the Alarm

CAUTION: Due to the loudness (85 decibels) of the alarm, always stand an arm's length away from the unit when testing.

The test/reset button serves two purposes: to test the unit's electronics and to reset the unit during a CO alarm. After installation, test the unit's electronics by pressing the test button for five seconds. A series of beeps will sound. If the unit chirps and the red LED flashes once every 30 seconds (with the green LED not flashing), it indicates a malfunction. In such a case, return the unit to our agent for repair.

If the alarm is sounding, pressing the button will silence the alarm for several minutes. After this duration, if the CO condition persists, the alarm will reactivate. The silencing duration ranges from 2 to 6 minutes.

The unit needs to be tested weekly!

If at any time it does not perform as described, verify power is connected correctly and that the battery does not need replacing. Clean dust and other buildup off the unit. If it still doesn't operate properly, call our agent.

LED Indicator Operation

  • Red LED: Flashes in conjunction with the alarm beep, during a CO alarm, a low battery chirp, and a malfunction status.
  • Green LED: Flashes once every 30 seconds to indicate proper operation. If it is out, it indicates malfunctioning.

What To Do If The Alarm Sounds

  1. Call your emergency services immediately.
  2. Immediately move to fresh air – outdoors or by an open door/window. Do a head count to ensure everyone is accounted for. Do not re-enter the premises or move away from the open door/window until emergency services responders have arrived, the premises have been aired out, and your alarm remains in its normal condition.

NEVER RESTART THE SOURCE OF A CO PROBLEM UNTIL IT HAS BEEN FIXED. NEVER IGNORE THE ALARM!

This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion. It is NOT designed to detect any other gas.

Fire departments and most utility companies will perform CO inspections; some may charge for this service.

Play video
Watch video online
Demonstration of the Carbon Monoxide Alarm, including battery installation and self-check function.

Maintenance

Battery Replacement:

If battery failure is detected, the unit will 'chirp' once every 30 seconds.

CAUTION: YOUR ALARM IS SEALED AND THE COVER IS NOT REMOVABLE!

To replace the battery, first remove the alarm from its mounting screws, then open the battery door. You can then directly replace the 3x 1.5V AA batteries. After installing or changing the battery, reinstall your alarm. Test your alarm using the test button and check that the red LED flashes once every 30 seconds.

CAUTION: Do not press the test/reset button while installing batteries. Otherwise, the unit will not work.

General Maintenance:

To keep your CO Alarm in good working order, please follow these simple steps:

  • Verify the unit's alarm and LED light operation by pushing the test button once a week.
  • Remove the unit from its mounting bracket and vacuum the alarm cover and vents with a soft brush attachment once a month to remove dust and dirt.
  • REINSTALL IMMEDIATELY AFTER CLEANING AND THEN TEST USING THE TEST/RESET BUTTON!
  • Never use detergents or other solvents to clean the unit.
  • Avoid spraying air fresheners, hair spray, or other aerosols near the CO Alarm.
  • Do not paint the unit. Paint will seal the vents and interfere with the sensor's ability to detect CO.
  • Never attempt to disassemble the unit or clean inside. This action will void your warranty.
  • WARNING: Reinstall the CO Alarm as soon as possible to assure continuous protection.
  • When household cleaning supplies or similar contaminants are used, the area must be well ventilated.

The following substances can affect the CO sensor and may cause false readings and damage: Methane, propane, iso-butane, iso-propanol, ethyl acetate, hydrogen sulfide dioxides, alcohol-based products, paints, thinner, solvents, adhesives, hair spray, after shave, perfume, and some cleaning agents.

Troubleshooting

Alarm Sounds:

If the alarm sounds, follow the 'What To Do If The Alarm Sounds' instructions in the Operation section immediately. Do not ignore the alarm.

Unit Chirps Every 30 Seconds:

This indicates a low battery. Replace the 3x 1.5V AA batteries as described in the 'Battery Replacement' section.

Green LED is Out or LCD Displays 'Er':

This indicates a unit malfunction. Ensure the unit is clean and batteries are fresh. If the issue persists, the unit may need repair or replacement. Contact our agent for assistance.

False Alarms:

Ensure the unit is not installed in areas prone to false alarms (e.g., near fuel-burning appliances, high airflow areas, dusty/greasy environments, or areas with strong chemical fumes). Refer to the 'When Not to Install' section for detailed guidance. If using household cleaning supplies, ensure the area is well-ventilated.

Carbon Monoxide Safety Information

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be deadly. The symptoms of CO poisoning are often mistaken for other illnesses.

Symptoms of CO Poisoning:

  • Mild Exposure: Slight headache, nausea, vomiting, fatigue (often described as 'flu-like' symptoms).
  • Medium Exposure: Severe throbbing headache, drowsiness, confusion, fast heart rate.
  • Extreme Exposure: Unconsciousness, convulsions, cardiorespiratory failure, death.

If you experience any symptoms of CO poisoning, seek medical attention immediately. CO poisoning can be determined by a carboxyhemoglobin test.

Everyone is susceptible to CO poisoning, but unborn babies, pregnant women, senior citizens, and people with heart or respiratory problems are especially vulnerable.

Carbon Monoxide Detector in various household and commercial settings
The detector is widely applicable in various environments, including kitchens, vehicle cabins, and indoor heating spaces.

User Tips

  • Always keep spare AA batteries on hand for quick replacement when the low battery alert sounds.
  • Regularly check the detector's placement to ensure it hasn't been accidentally covered or obstructed, which could impair its function.
  • While this product is CE certified, if specific local regulations require UL listing, please verify compliance before purchase.

Frequently Asked Questions (FAQ)

Q: Are these UL listed?
A: Based on the provided specifications, this product is CE certified. UL listing is a different certification primarily for the North American market. Please check local regulations for specific requirements.

Warranty and Support

This Carbon Monoxide Detector is designed for reliable performance. In the event of a malfunction not resolved by troubleshooting or maintenance, please contact the seller or an authorized service agent for repair or replacement.

Please refer to the original purchase documentation for specific warranty terms and conditions.

For further assistance, you may refer to the official user manual PDF: View User Manual (PDF)

© 2024 Gaqqee. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.