1. Overview
The ZOYI ZT-703S+ is a versatile handheld device that integrates the functions of an oscilloscope, signal generator, and multimeter into a single unit. It features a durable dual injection molding process, a compact design for portability, and intuitive operation. The device is equipped with a 3.5-inch IPS full-view color display and offers a multimeter display of up to 25,000 counts. Its superior performance and extensive functionality make it suitable for a wide range of measurement scenarios.
2. Safety Instructions
To prevent electric shock, fire hazards, or personal injury, please read and adhere to the following safety precautions before using the device:
- Use the product only for its designated purpose.
- Before each use, inspect the housing for cracks or plastic damage and carefully check the insulation near the input ports.
- Always use the correct input ports and set the appropriate measurement range as specified in this manual.
- Do not use the device in the presence of explosive gases, vapors, or in humid environments.
- Keep your fingers behind the protective shield of the test probe.
- Avoid touching unused input ports when the device is connected to a circuit under test. Disconnect test probes and the circuit before changing the test range.
- Exercise extreme caution when measuring DC voltages above 36V or AC voltages above 25V, as these can cause serious harm.
- Never operate the device with the front or rear cover open.
- Recharge the battery promptly when low, as it may affect measurement accuracy.
- The ground line between the two channels is common; ensure the ground clip is always grounded or connected to the same potential during measurements.
- When charging via USB, ensure the probe's ground wire does not touch high voltage to prevent damage or injury.
- When measuring voltages higher than AC 25V or DC 36V with an oscilloscope probe, ensure the USB protective cover is securely closed to prevent contact with exposed metal parts.
3. Setup
3.1. Package Contents
The ZOYI ZT-703S+ package typically includes:
- ZOYI ZT-703S+ 3-in-1 Device
- Test Leads (Red and Black)
- Oscilloscope Probe
- USB Type-C Charging Cable
- Carrying Pouch
- User Manual (this document)

3.2. Main Interface Overview
Familiarize yourself with the main components and controls of your device:

- CH1 Input / CH2 Input: BNC connectors for oscilloscope probes.
- USB Interface: Type-C port for charging and data transfer.
- Signal Generator Output Port: Output for generated waveforms.
- Multimeter Measurement Input Terminal: Ports for multimeter test leads (10A, mA, COM, VΩHz).
- Display Screen: 3.5-inch IPS full-view color display.
- Keys Pad: Navigation buttons (Up, Down, Left, Right, MENU), Function keys (F1-F4), Mode, Auto/Range, Hold/Save, and Power button.
3.3. Battery Charging
When the battery icon on the top right of the screen indicates low power, charging is required:
- Connect the USB Type-C cable to a DC 5V output adapter or a computer's USB port.
- During charging, the screen will display a charging icon, and a red light on the power button will illuminate.
- The device is fully charged when the charging icon changes to a full battery icon, and the red light on the power button either flashes or turns off.
3.4. Probe Inspection and Compensation
Before using the oscilloscope probe, ensure it is properly compensated for accurate measurements.
- Safety: Always keep your fingers behind the safety collar on the probe body. Do not touch the metal parts of the probe when connected to a high-voltage source. The maximum voltage should not exceed 150V for 1X range or 300V for 10X range.
- Manual Compensation: Connect the probe to the signal input terminal and input a 1KHz square wave signal. Press the AUTO key on the panel. Observe the waveform: it should be a clean square wave. If it shows overcompensation (rounded corners) or undercompensation (spikes), adjust the compensation screw on the probe until the waveform is square.
3.5. Probe Attenuation Setting
Ensure the attenuation switch on your oscilloscope probe (typically X1 or X10) matches the probe attenuation setting in the oscilloscope's system menu. This is crucial for correct vertical scale readings.
4. Operating Instructions
4.1. General Operation
- Power On/Off: Long press the power button for 2 seconds.
- Mode Switching: Press the MODE button to switch between Oscilloscope, Signal Generator, and Multimeter modes.
- Navigation: Use the arrow keys (Up, Down, Left, Right) to navigate menus and adjust parameters. Press the MENU button to access system settings.
4.2. Oscilloscope Mode
The oscilloscope mode allows for waveform visualization and analysis.
- Channel Settings: Press MENU, then navigate to the Channel Settings page. Use F1 to switch between CH1/CH2, F2 to enable/disable channels, F3 to select coupling (DC/AC), and F4 to set probe attenuation (X1/X10).
- Automatic Setup: For unknown waveforms, press the AUTO key to automatically adjust settings for optimal display.
- Vertical System: Adjust voltage amplitude, scale, and position. Use F1 (Voltage/Time menu) and arrow keys for voltage. Use F2 (Waveform Move menu) and arrow keys for vertical position.
- Horizontal System: Adjust time base and horizontal position. Use F1 (Voltage/Time menu) and arrow keys for time base. Use F2 (Waveform Move menu) and arrow keys for horizontal position. Long-press MENU to center the horizontal cursor.
- Trigger System: Configure how the oscilloscope captures waveforms. Access trigger settings via MENU. Set trigger mode (Auto, Normal, Single), edge (Rising/Falling), source (CH1/CH2), and position.
- Numeric Measurement: Access via MENU. Use AUTO for automatic measurements or F3 for specific numeric displays (VPP, Vmax, Vmin, FRQ, PRD, RMS, Duty Cycle).
- XY Display Mode: Access via MENU (fifth page, F1) to display Lissajous patterns.
- Persistence Time: Access via MENU (fifth page, F2) to set waveform persistence (Min, 500ms, 1S, 10S, Infinite).
- FFT (Fast Fourier Transform): Access via MENU (fifth page, F3) to analyze frequency components.
- Backlight Time: Access via MENU (fifth page, F4) to set auto-off time for backlight (30S, 60S, 120S, Off).
- Cursor Measurement: Access via MENU (sixth page) to measure specific points on the waveform using horizontal or vertical cursors.
- Saving Waveforms: Press and hold HOLD/SAVE for 2 seconds to save the current waveform as an image. Saved waveforms can be browsed via MENU (sixth page, F1) or accessed on a computer by connecting via USB-C (MENU, third page, F3).
4.3. Signal Generator Mode
The signal generator can output various waveforms for testing purposes.

- Output Waveform Settings: In Signal Generator mode, press MENU (sixth page, F4) to access output settings. Select waveform type (sine, square, triangular, half, full, sawtooth), frequency, amplitude, and duty cycle using arrow keys and MENU to confirm.
- Signal Output Control: Press MENU to toggle the ON/OFF switch for signal output. Connect an oscilloscope probe to the Signal Generator Output Port to observe the generated waveform.
4.4. Multimeter Mode
The multimeter mode provides precise measurements of electrical parameters.
- Input Terminals: Use the COM port for common ground. Use 10A for high current, mA for low current, and VΩHz for voltage, resistance, capacitance, frequency, continuity, and diode measurements.
- Measuring AC/DC Voltage: Insert black probe into COM, red into VΩHz. Select voltage range (mV or V) using F4 or F1. Contact probe tips to test points.
- Measuring AC/DC Current: Insert black probe into COM, red into 10A or mA. Select current range using F3. Switch between DC/AC using the corresponding menu key.
- Measuring Resistance: Insert black probe into COM, red into VΩHz. Press F2 for resistance mode. Ensure circuit is powered off and capacitors discharged.
- Testing Continuity: Insert black probe into COM, red into VΩHz. Press F2 (in resistance mode) for continuity. A buzzer indicates a short circuit.
- Measuring Diode: Press F2 (in continuity mode) for diode test. Red probe to anode, black to cathode. Reads forward voltage.