1. General Information
The MYOslim Sculpt Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) to induce powerful muscle contractions. This process promotes muscle growth and reshapes internal muscle structure. Additionally, the intense muscle contractions trigger significant fat breakdown, releasing fatty acids from triglycerides, which are then metabolized by the body over several weeks.
Advanced HI-EMT Technology
Achieves intense muscle contractions with high-energy focused electromagnetic waves to promote muscle growth and reshape deep internal structures.
Touch-Controlled Display
The touch control display simplifies device operation, providing clear information. Screen brightness is adjustable for various lighting conditions, and the user-friendly interface guides through the treatment process.
Real-time Monitoring and Guidance
During treatment, the display shows remaining treatment time, utilized channels, treatment methods, applied treatment types, attachments used, and other necessary information for real-time monitoring and guidance.
Upgradeability
The EMSZERO series offers flexible upgrade options to meet future therapeutic needs.
Indications for Use
The EMSZERO is intended for:
- Improvement of abdominal tone, strengthening of abdominal muscles, and development of a fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness for strengthening muscles in arms.
Operating Environment
A proper operating environment is crucial for the effectiveness and safety of the device:
- Clean and Hygienic Environment: The area should be clean and hygienic to prevent contamination. Regular cleaning and disinfection of the equipment and accessories are essential.
- Appropriate Temperature and Humidity: Ensure the environment's temperature and humidity are within the manufacturer's specified range. Extreme conditions can affect device performance.
- Adequate Lighting: Provide sufficient lighting for clear visibility and correct operation, especially for precise procedures.
- Good Ventilation: The operating area should have adequate ventilation to ensure air circulation and prevent accumulation of harmful gases.
- Safety Measures: The environment should include appropriate safety measures like fire extinguishers and first aid equipment. Operators should be familiar with safety procedures.
- Avoidance of Interference Sources: Keep the equipment away from strong electromagnetic fields or other devices that could cause interference.
Patient Profile
This device is suitable for healthy adults without physical illnesses or metal objects in their body.
Contraindications
Do NOT use the device if any of the following apply:
- Open wounds on the skin.
- Patients with heart disease (e.g., arrhythmias, pacemakers).
- Cancer patients.
- Patients with infectious diseases.
- Pregnant or lactating women, or during menstrual period.
- Patients who have undergone major surgery or have diabetes.
- Presence of any metal in the body.
- People with cerebrovascular disease (stroke patients).
Possible Side Effects
These may include, but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
Safety Precautions and Warnings Before Use
- Do not use when feeling full; wait at least one hour after meals.
- Remove all metal jewelry before using the instrument.
- Before starting operation, touch the probe vertically to the skin, then turn on the main unit and adjust intensity.
- Start at the lowest intensity level and gradually increase according to user's skin tolerance.
- It is forbidden to eat or drink during operation. Try to eat one hour after operation.
2. Setup
Device and Accessories Overview
The MYOslim Sculpt Machine is designed for ease of use and effective treatment. Below are the key components and accessories.

Figure 1: Front View of the MYOslim Sculpt Machine (White)

Figure 2: Rear View of the MYOslim Sculpt Machine (White)
Key Components (Front View):
- Handle: Treatment applicators.
- Display Screen: Touch-controlled interface for operation.
Key Components (Rear View):
- Screen Power Switch: Controls power to the display.
- Handle Bracket: Holds the treatment handles.
- Handle Socket: Connection point for handles.
- Ventilation Holes: For heat dissipation.
- Fuse: Safety component.
- Power Cord Socket: Main power input.
- Power Switch: Main power control.
Note: The handles can only be used with the original machine and are not interchangeable with other devices.
List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| 3 | Belts (8*80CM, 8*90CM, 8*100CM) | 3 | |
| 4 | Power cable | 1 | |
| 5 | Electronic manual | 1 copy |
Device Installation
- Install the handle bracket: Use a screwdriver to install the handle brackets on both sides of the machine. Ensure they are securely fastened.

Figure 3: Handle Bracket Installation
- Handle film application: Apply the black film to the working part of the handle.

Figure 4: Handle Film Application
- Installing the handle: Align the hole and fasten the clip. Lock the key ring.

Figure 5: Handle Installation
- Connect power: Connect one end of the power cord to the machine and the other end to a socket. Do not connect multiple machines to one socket.

Figure 6: Power Connection
- Press the back switch: Locate and press the power switch on the back of the machine.
- Press the front switch: Single-click the front power button to turn on. Long press to turn off.
3. Operating Instructions
Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the 'I' position (ON).
- Press the power button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
Handle Exchange
Important: The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
Navigation Controls and Therapy Settings
The pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

Figure 7: Therapy Setting Interface
- [1] Navigation controls: Access different sections of the interface.
- [2] Channels selector: Select active treatment channels.
- [3] Stop therapy: Halt the current treatment.
- [4] Start/pause therapy: Begin or pause treatment.
- [5] Setting up therapy parameters: Adjust treatment intensity, frequency, and time.
- [6] Return: Go back to the previous screen.
- [7] Settings: Access device settings (language, sound, brightness, date/time, system, technician).
Unit Settings
Access various device settings through the 'Settings' menu:

Figure 8: Unit Settings Interface
- Language Settings: Adjust the display language.
- Sound Settings: Control device sounds.
- Brightness Settings: Adjust screen brightness.
- Date and Time Settings: Set the current date and time.
- System Settings: Access system-level configurations.
- Technician: Access technician-specific settings (password protected).
Therapy Modes
The device offers different therapy modes with adjustable parameters.
Mode 1 Operation
The operation interface for Mode 1 allows adjustment of handle RF energy regulation and handle strength. The frequency range for Mode 1 is 5-60Hz.

Figure 9: Mode 1 Therapy Interface
Note: Always take out the handle from the handle frame before operation and use the belt to fix the handle to the operating part. Adjust intensity according to customer needs. To pause, click start/pause. To return after work is completed, click the back button.
Mode 2 Operation
Mode 2 also allows adjustment of handle RF energy regulation and handle strength, with a frequency range of 30-100Hz. It offers three different periodic frequencies that can be freely selected.

Figure 10: Mode 2 Therapy Interface
Single Handle Operation
To achieve single handle work, pull the intensity of the unused handle to its lowest value (zero). For example, if intensity 1 is at its lowest, handle B works alone. If intensity 2 is at its lowest, handle A works alone.

Figure 11: Single Handle Operation Interface
Note: Align the handle with the operating part and attach it. Press the start button on the screen to begin. Lightly place the handle on the handle holder after use.
Preparing for Therapy
- Communicate with patients to understand their needs and conditions.
- Ensure the patient is in good health and has no contraindications.
- Advise the patient to stay hydrated.
- Ensure the patient wears appropriate clothing that allows access to the treatment area.
- Advise the patient to avoid eating large quantities before the session.
- Familiarize yourself with the treatment process.
- Advise the patient to avoid drinking alcohol before treatment.
Placing the Handle
The handles can be placed on various body parts depending on the desired treatment area:

Figure 12: Handle Placement Examples
- Belly: For abdominal toning and muscle strengthening.
- Buttock: For strengthening, toning, and firming.
- Arm: For muscle tone and firmness.
- Thigh: For strengthening, toning, and firming.
- Calf: For strengthening, toning, and firming.
- Arse: For shaping and lifting.
Note: Operate according to the controller model purchased and follow manufacturer's official documentation for best experience. Contact customer support for questions.
4. Maintenance
Daily Inspection
Regularly inspect instruments and components. Ensure the power socket has a reliable ground connection. Check the power cord for damage before use; if damaged, stop using the instrument immediately.
Cleaning
- Device Surface: The device housing can be wiped with a damp cloth, soapy water, or a neutral detergent while the instrument is powered off. Do not use alcohol-based detergents on painted parts.
- Accessories in Contact with Patient: Parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after each use. Do not soak these parts in alcohol-based detergent; wipe with pure cotton material.
Fuse Replacement
The fuse is located below the handle junction on the back of the machine. An additional spare fuse is included. To prevent electric shock, always turn off the power and unplug the power plug before replacing the fuse.
Storage and Transportation
- Storage: Store the instrument in its original packaging box in a well-ventilated room. The packaging should be cushioned with padding. Maintain ambient temperature between -10°C and 40°C and relative humidity below 93%. Avoid environments with harmful gases, flammable, explosive, or corrosive substances.
- Transportation: The instrument in its packaging is suitable for road, rail, air, and water transportation. Protect from severe vibrations and impacts. Avoid exposure to moisture and mixing with flammable or corrosive substances.
Term of Use
The warranty period for the instrument is 1 year (excluding man-made damage). The warranty period for accessories is 3 months (excluding man-made damage). Continued use beyond the service period requires engineer approval and periodic performance tests.
5. Troubleshooting
Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | Power plug not inserted into socket Power switch not on Power fuse failure | Check the power Check the power switch Replace the fuse |
| Handle not working | Check the handle for loose connection | Reseat the handle |
6. Specifications
Technical Parameters
| Name | Specification |
|---|---|
| Brand Name | MYOSLIM |
| Item Type | Massage & Relaxation |
| Style | PORTABLE / Desktop |
| Material | ABS+Steel |
| Power Supply | Direct Current |
| Input Power Supply | AC110V-220V 50/60Hz |
| Voltage | 50-1000V AC |
| Output Maximum Power | 0-1500W |
| Frequency | 5-200HZ |
| Screen Size | 15 inches |
| Product Size | 54*47*50cm |
| Net Weight | 22.3kg |
| Certification | CE, RoHS |
| Origin | Mainland China |
Electromagnetic Compatibility (EMC)
The device has undergone Radiated Electromagnetic Field Immunity Test with the following parameters:
- Port: Enclosure
- Basic Standard: IEC 61000-4-3:2020
- Test Level: 30V/m with 80% AM. 1kHz Modulation
- Standard Requirement: A
- Tester: Sam Liu
- Temperature: 25°C
- Humidity: 54%
7. Warranty and Support
Warranty Information
- The main machine can be replaced with a new one within 7 days from the date of purchase (with receipt and intact appearance).
- The main machine is guaranteed for one year (excluding fragile parts and other non-warranty scope or expired warranty).
- Maintenance and updates may incur charges after the warranty period.
- Free warranty service is not provided for failures caused by personal reasons, including:
- Unauthorized disassembly and modification.
- Accidental fall.
- Lack of reasonable maintenance.
- Failure to operate according to the correct instructions in this manual.
Manufacturer Contact
If you have a problem, need service, or other information, please contact the manufacturer:
- Manufacturer: Guangzhou Xinwei Electronics Technology Co., Ltd.
- Manufacturing Address: Room 01, 10th Floor, No. 23 Boyan 2nd Road, Baiyun District, Guangzhou
Additional Resources
A detailed user manual in PDF format is available for download. This document provides comprehensive instructions and specifications for the MYOslim Sculpt Machine. You can access the PDF manual here.
8. User Tips
- For optimal results, ensure consistent use as recommended by a professional or the device's guidelines.
- Always start with the lowest intensity and gradually increase to a comfortable level to avoid discomfort or muscle strain.
- Maintain good hydration before and after sessions to support muscle function and recovery.
- Regularly clean the device and its accessories to ensure hygiene and prolong the lifespan of the equipment.
- Store the machine in a cool, dry, and well-ventilated area, away from direct sunlight and extreme temperatures.