myoslim EMS RF Body Sculpting Machine

Contents

Professional EMS RF Body Sculpting Machine User Manual

Model: EMS RF Body Sculpting Machine | Brand: myoslim

1. General Information

The EMS Body Sculpt series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.

Advanced HI-EMT Technology:

The EMS Body Sculpt series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.

Touch-Controlled Display:

The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.

Real-time Monitoring and Guidance:

Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.

Upgradeability:

As your therapeutic needs evolve, you may wish to upgrade your equipment later on. The EMS Body Sculpt series offers flexible upgrade options to meet your future treatment requirements.

1.1 Indications for Use

EMS Body Sculpt is intended for:

  • Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
  • Strengthening, Toning and Firming of buttocks, thighs and calves.
  • Improvement of muscle tone and firmness, for strengthening muscles in arms.

1.2 Operating Environment

The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.

  • Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
  • Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
  • Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
  • Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
  • Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
  • Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
  • Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.

1.3 Patient Profile

This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.

1.4 Description of the Device

EMS Body Sculpt enables a simple and effective treatment process that you can easily perform by adjusting the digital energy selection treatment plan or diagnostic procedure. Additionally, any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.

2. Safety Precautions and Warnings

Precautions before use:

  • Do not use when feeling full; wait at least one hour after meals.
  • Before using the instrument, remove any metal jewelry you are wearing.
  • Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
  • Set the intensity to the lowest level, and then increase the intensity sequentially according to the user's skin tolerance.
  • It is forbidden to eat or drink during the operation, and try to eat after one hour after the operation.

1.5 Contraindications

Do not use this device if any of the following apply:

  • Wounds on the skin (or avoid wounds when using).
  • Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
  • Cancer patients.
  • Patients with infectious diseases.
  • Pregnant women, lactating women, menstrual period.
  • Major surgery patients, diabetic patients.
  • Having any metal in the body.
  • People with cerebrovascular disease (stroke patients).

1.6 Possible Side Effects

These effects may include but are not limited to:

  • Muscle soreness.
  • Reduction in muscle fat.
  • Temporary muscle spasms.
  • Transient joint or muscle tendon pain.
  • Localized redness or skin flushing.

3. Device and Accessories

3.1 Front and Rear Panel of the Main Unit

The main unit features a display screen and connections for the EMS handles.

Front view of the EMS Body Sculpting Machine with display and handles

Image: Front view of the EMS Body Sculpting Machine, showing the display screen and attached EMS handles.

Note: The handle can only be used by the original machine and cannot be used interchangeably.

3.2 Handle Types

The machine supports different types of handles for various applications:

  • Standard Handles (2 or 4 handles)
  • RF Handles (4 or 5 handles)
  • Cushion Handle (optional accessory)
EMS handles for body sculpting machine

Image: Various types of EMS handles, including standard and RF handles.

3.3 List of Accessories

Serial Name Quantity Picture
1 Host 1 set Host machine
2 Handle 2 EMS Handle
Handle 2 EMS Handle
Cushion (optional accessories) 1 Cushion handle
3 Belt 7*100CM*2, 5*60CM*2 Belt for handles
4 Power cable 1 Power cable
5 Electronic manual 1 copy Electronic manual icon

4. Device Installation

1. Install the handle bracket

Use a screwdriver to install the handle brackets on both sides of the machine.

Diagram for installing handle bracket

Image: Diagram showing the installation of the handle bracket on the side of the machine.

2. Handle film

Stick the protective film to the working part of the handle.

Diagram for applying handle film

Image: Diagram illustrating how to apply the black protective film to the handle.

3. Installing the handle

Align the hole and fasten the clip, then lock the key ring.

Diagram for installing the handle

Image: Diagram showing the process of installing and securing the handle to the machine.

4. Connect power

Connect one end of the power cable to the machine and the other end to the socket.

Diagram for connecting power cable

Image: Diagram illustrating how to connect the power cable to the machine and a power outlet.

5. Press on the back switch

Ensure the power switch is in the 'off' position before connecting. Once connected, press the switch to 'on' to power the machine.

Diagram for power switch

Image: Diagram showing the power switch on the back of the machine, indicating 'off' (light not on) and 'on' (light on) states.

5. Basic Device Operation

5.1 Handle Exchange

The handle must be calibrated every time it is installed or replaced.

Warning: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.

5.2 Device Start Up/Shut Down

  1. Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
  2. Move the manual switch on the rear panel to the "o" position.
  3. Press the button on the front panel.
  4. When the treatment is finished, press and hold the power button to turn off the machine.

5.3 Navigation Controls

5.3.1 Setting the Therapy by Controls

Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

Operation interface for therapy settings

Image: Screenshot of the therapy settings interface, showing navigation controls, channel selector, stop/start therapy, and therapy parameters.

  • Navigation controls
  • Channels selector
  • Stop therapy
  • Start/pause therapy
  • Setting up therapy parameters

5.4 Unit Settings

The operation interface of mode 1 allows you to adjust handle operation time according to customer needs. Take out the handle from the handle frame before operation, and use the belt to fix the handle to the operating part required by the customer. The frequency of mode one is 5-60Hz.

Unit settings interface for Mode 1

Image: Screenshot of the unit settings interface for Mode 1, showing time adjustment, handle RF energy regulation, handle strength adjustment, and start/stop buttons.

Note: Adjust the corresponding intensity according to different customer needs to start the operation. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.

The operation interface of mode 2 allows for adjustment of intensity, stage frequency, and time. The frequency of mode two is 30-100Hz.

Unit settings interface for Mode 2

Image: Screenshot of the unit settings interface for Mode 2, showing time adjustment, handle RF energy regulation, handle strength adjustment, and start/stop buttons, with options for 3 different periods of frequency.

Note: Adjust the corresponding intensity/stage frequency/time according to different customer needs, click the start/pause work button to enter the operation work, if any. When the customer requests to pause, they can click the start/pause work button to pause the work, and after the work is completed, they can directly click the return key to return.

Other Settings:

  • Language settings
  • Sound adjustment
  • Brightness adjustment
  • Set date and time
  • System adjustment
  • Technician access
Language settings interface

Image: Screenshot of the language settings interface.

Sound adjustment interface

Image: Screenshot of the sound adjustment interface.

Brightness adjustment interface

Image: Screenshot of the brightness adjustment interface.

Set date and time interface

Image: Screenshot of the date and time setting interface.

System adjustment interface

Image: Screenshot of the system adjustment interface.

Technician access interface

Image: Screenshot of the technician access interface, requiring a password.

6. Therapy

6.1 Preparing the Therapy

  1. Communicate with patients.
  2. Ensure good health.
  3. Stay hydrated.
  4. Wear appropriate clothing.
  5. Avoid eating in large quantities.
  6. Familiarize with the treatment process.
  7. Avoid drinking alcohol.

6.2 Placing the Handle

The handles can be placed on various body parts depending on the desired treatment area. Ensure the handles are securely fastened with the provided belts.

Handle placement on belly

Image: Correct handle placement for abdominal (belly) treatment.

Handle placement on buttocks

Image: Correct handle placement for buttocks treatment.

Handle placement on arm

Image: Correct handle placement for arm treatment.

Handle placement on thigh

Image: Correct handle placement for thigh treatment.

Handle placement on calf

Image: Correct handle placement for calf treatment.

Handle placement on pelvic area

Image: Correct handle placement for pelvic area treatment.

Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.

7. Maintenance and Repair

7.1 Maintenance

7.1.1 Daily inspection

Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Please check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.

7.1.2 Cleaning

Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off.

7.1.3 Replacing the fuse

When replacing the fuse, in order to prevent electric shock, please turn off the power and unplug the power plug.

8.1 Fuse Replacement

The fuse is set below the handle junction on the back of the machine. An additional spare fuse is included.

8.2 Cleaning the Surface of the Device

The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean, do not use alcohol-based detergents.

8.3 Cleaning of Accessories that Come into Contact with Patient

The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole, wipe with pure cotton material.

8.4 Transport and Storage

Storage:

The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C. The relative humidity should not be greater than 93%, and it is not allowed to be placed in harmful gases, around flammable, explosive substances and corrosive gases.

8.5 Term of Use

  • The warranty period of this instrument is 1 year (note: man-made damage is excluded).
  • The warranty period for accessories is 3 months (note: man-made damage is excluded).
  • The continued use of the instrument beyond the service period shall be subject to the approval of the engineer, and the engineer shall conduct a performance test of the instrument periodically in the subsequent use.
  • Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.

8.6 Common Faults and Troubleshooting Methods

Fault phenomenon Causes Exclusions and workarounds
Device not working The power plug is not inserted into the socket
Power switch not on
Power fuse failure
Check the power
Check the power switch
Replace the fuse
Handle not working Check the handle for loose connection Reseat the handle

9. Technical Parameters

Name Value
High-concerned chemical None
Hand Instrument No
Electronic No
Power Supply Alternating Current
Voltage AC220V/50Hz AC110V/60Hz
Material ABS
Brand Name myoslim
Origin Mainland China
Certification CE, RoHS
Item Type Epilator, Massage & Relaxation
Epilator Type Pincent
Use BODY
Power Type Electric
Name EMS Body Shaping Machine
Frequency 5-200Hz
Energy 15Tesla
Power 6500W
Machine size 43*40*91cm
Packing size 65*58*114cm
Weight 65KG
Warranty 1 year
After-sales Service Provided Online support, Video technical support
Handles 2 Handles/4 Handles/5 Handles
Type High-Energy Focused Electromagnetic Waves
Feature Weight Loss, Other, Skin Tightening, Cellulite Reduction
Technology EMS+HI-EMT
Color Gray/Black
Applicable locations Salon/Home

9.1 Electromagnetic Compatibility

The device is designed to comply with electromagnetic compatibility standards. Refer to the provided diagram for test setup details.

Electromagnetic Compatibility Test Setup Diagram

Image: Block diagram of the electromagnetic compatibility test setup, showing the 7x4x3 chamber, EUT & Support, Power Amp, Signal Generator, EUT Monitoring camera, and Contro Room.

10. Warranty and Support

The main machine is guaranteed for one year from the date of purchase (with receipt), excluding fragile parts and non-warranty scope or expired warranty period. Maintenance and updates may incur charges. If the instrument breaks and needs repair, the buyer bears the return shipping cost within six months of purchase, and the seller bears the shipping-in cost. After six months, the buyer bears all shipping costs. Free warranty service is not provided for failures caused by personal reasons, unauthorized disassembly, accidental fall, lack of reasonable maintenance, or failure to operate according to the instructions in this manual.

For after-sales service, including online support and video technical support, please contact the seller directly. Do not attempt repairs without authorization.

For detailed warranty information, please refer to the Warranty Card section in the official user manual (PDF available for download).

User Tips

  • Start with a lower intensity setting and gradually increase it as you become comfortable.
  • Consistency is key: regular sessions (e.g., 15-30 minutes per session, 2-3 times a week) are recommended for best results.
  • Combine treatments with proper hydration and a balanced diet for enhanced body shaping outcomes.
  • The device is effective for targeting areas like the waist, abdomen, buttocks, arms, and thighs.
  • The machine's design is user-friendly, with a clear interface and easy-to-adjust settings.
  • Ensure handles are securely fastened to the body part being treated.
  • Listen carefully to the working sounds of the machine during operation.

Frequently Asked Questions (FAQ)

Q: How do I get detailed information about my purchase?

A: You can consult the online seller for detailed information about your purchase.

Q: Can I get the machine with specific handles, like 2 for abdomen, 2 for arms, and 1 pelvic?

A: For specific handle configurations and purchase details, please contact the seller online for more information.

Q: What about customs taxes for delivery to Spain?

A: For better assistance regarding customs taxes and delivery to specific countries, please consult the online seller directly.

© 2024 myoslim. All rights reserved.

Manufacturer: Guangzhou Xinwei Electronic Technology Co., Ltd.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.