1. Introduction
The Myoslim Cryoskin Slimming Toning Machine is an advanced beauty device designed for body contouring, skin tightening, cellulite reduction, and fat loss. It utilizes innovative thermal shock technology, combining cryotherapy (cooling) and heat therapy to rapidly change the temperature of fat cells, thereby accelerating fat breakdown and promoting body shaping effects. This non-surgical approach is safe, comfortable, and suitable for various skin types and body areas.
This manual provides essential information for the safe and effective operation and maintenance of your Cryoskin Slimming Toning Machine. Please read it thoroughly before initial use.
2. Safety Information
- Always ensure the device is connected to a grounded power outlet with the correct voltage (AC220V/50Hz or AC110V/60Hz).
- Do not operate the device with wet hands or in damp environments.
- Keep the device out of reach of children and pets.
- Consult a healthcare professional before use if you have any underlying medical conditions, especially heart conditions, pacemakers, skin sensitivities, or are pregnant.
- Avoid direct contact with eyes or mucous membranes.
- Do not use on broken, irritated, or infected skin.
- Discontinue use immediately if you experience any discomfort or adverse reactions.
- Ensure proper ventilation around the machine during operation.
3. Product Overview
The Cryoskin Slimming Toning Machine features a main unit with a touchscreen interface and various treatment heads designed for different applications.
3.1 Components
- Main Unit: Houses the control panel, power supply, and internal mechanisms.
- Round Heads (2): Used for targeted treatments, often for smaller areas or specific contouring.
- Freezing Plates (2): Designed for broader application areas, providing efficient cooling and heating.
- Power Cable: For connecting the device to an electrical outlet.



4. Setup
- Unpacking: Carefully remove all components from the packaging. Retain packaging for future storage or transport.
- Placement: Place the main unit on a stable, flat surface in a well-ventilated area.
- Connect Handles: Connect the round heads and freezing plates to their respective ports on the main unit. Ensure connections are secure.
- Power Connection: Plug the power cable into the designated port on the machine, then into a suitable electrical outlet.
- Initial Power On: Press the main power button to turn on the device. The touchscreen display should illuminate.

5. Operating Instructions
The device features a touchscreen operation with real-time temperature monitoring to ensure safety and effectiveness. A single treatment typically takes only 30 minutes, making it suitable for busy daily lives.
5.1 Powering On/Off
- Power On: Press the main power button on the device. The screen will display the EMS Zero logo and then the main interface.
- Power Off: Press and hold the power button until the device shuts down, or use the software shutdown option on the touchscreen if available.
5.2 Interface Navigation
The touchscreen interface allows you to select treatment modes, adjust parameters, and monitor the treatment process. The main screen typically shows options for different applicators (round heads, freezing plates) and treatment settings.
5.3 Treatment Modes and Settings
The device employs alternating hot and cold thermal shock technology (hot-cold-hot) to rapidly change the temperature of fat cells. This process accelerates fat breakdown and achieves body shaping effects without the need for suction, preventing bruising or swelling.
- Select Applicator: On the main screen, choose the desired applicator (round head or freezing plate) for your treatment area.
- Choose Treatment Program: The device offers various programs (A, B, C, D) with pre-set time, temperature, and EMS levels. Select the program suitable for your needs.
- Adjust Parameters (Optional): You can manually adjust the following parameters for each program:
- Time: Treatment duration (e.g., 30 minutes).
- Temp: Temperature setting (e.g., 30°C for heating, -01°C for cooling).
- EMS: Electrical Muscle Stimulation level (e.g., 10, 22, 60).
- Start Treatment: Press the 'Play' button to begin the treatment. The screen will display the current phase (Heating, Cooling) and real-time temperature.
- Monitor Progress: The device monitors temperature in real-time. Ensure the applicator maintains good contact with the skin throughout the session.
- End Treatment: The device will automatically stop after the set time. You can also pause or stop the treatment manually.
5.4 Application Areas
The Cryoskin Slimming Toning Machine is suitable for various body areas, including:
- Abdomen
- Buttocks
- Thighs
- Arms
- Upper Back
- Double Chin (for precise treatment of smaller areas)


6. Maintenance
- Cleaning: After each use, wipe down the treatment heads and the main unit with a soft, damp cloth. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure all cables are neatly coiled and not kinked.
- Inspection: Regularly inspect the power cable and treatment heads for any signs of damage. If any damage is found, contact customer support before further use.
7. Troubleshooting
If you encounter any issues with your device, please refer to the following common troubleshooting steps:
- Device not powering on: Check if the power cable is securely connected to both the device and the power outlet. Ensure the outlet is functional.
- No cooling/heating: Verify that the selected program is active and the temperature settings are correctly applied. Ensure the applicator is making proper contact with the skin.
- Touchscreen unresponsive: Try restarting the device. If the issue persists, contact customer support.
- Unusual noises or odors: Immediately power off the device and unplug it. Contact customer support for assistance.
For more detailed troubleshooting or issues not listed here, please refer to the full user manual (PDF) available for download or contact customer support.
8. Specifications
| Feature | Specification |
|---|---|
| Product Designation | Cold and hot slimming device |
| Model Series | B01-B35 |
| Power Supply | Alternating Current (AC220V/50Hz or AC110V/60Hz) |
| Voltage | 50-1000V AC |
| Material | Composite Material, ABS+Steel |
| Style | Portable / Desktop |
| Application | For Commercial, Beauty Center & Clinic |
| Package Length | 15 cm |
| Package Width | 15 cm |
| Package Height | 15 cm |
| Package Weight | 15.0 kg |
9. Certifications
The Myoslim Cryoskin Slimming Toning Machine complies with European Union directives for electromagnetic compatibility and low voltage.
9.1 EU-EMC Directive 2014/30/EU
Registration No.: ENC2303052GZ15-1
Applied Standards:
- EN IEC 55014-1:2021
- EN IEC 61000-3-2:2019+A1:2021
- EN 61000-3-3:2013+A1:2019+A2:2021
- EN IEC 55014-2:2021
Test Report No.: ENC2303052GZ15E1
9.2 EU-Low Voltage Directive 2014/35/EU
Registration No.: ENC2303052GZ15-2
Applied Standards:
- EN 60335-1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019+A15:2021
- EN 60335-2-23:2003+A1:2008+A2:2015
- EN 62233:2008
Test Report No.: ENC2303052GZ15L1
The product bears the CE mark, indicating conformity with relevant EU health, safety, and environmental protection standards.
10. Warranty and Support
The Cryoskin Slimming Toning Machine comes with a 12-month (1 year) warranty.
After-sales Service Provided:
- Free spare parts
- Video technical support
- Online support
Our Service:
- 24 hours online service
- Instructions operation video training
For any inquiries or support needs, please contact your seller or the manufacturer directly.
11. User Tips
- For optimal results, maintain a healthy diet and regular exercise routine in conjunction with treatments.
- Stay hydrated by drinking plenty of water before and after sessions.
- Consistency is key; follow a recommended treatment schedule for best outcomes.
- Ensure the skin is clean and dry before applying the treatment heads.
- Always use the device as instructed to avoid potential skin irritation or discomfort.
12. Frequently Asked Questions (FAQ)
- Is the treatment painful? The thermal shock technology is designed to be safe and comfortable, eliminating the need for suction which can cause bruising. Most users report minimal to no discomfort.
- How long does a session take? A single treatment session typically takes only 30 minutes, making it convenient for daily use.
- Which areas can be treated? The device is suitable for the abdomen, buttocks, thighs, arms, upper back, and even smaller areas like the double chin.
- How quickly will I see results? Many users report visible improvements in fat reduction and skin quality after a few sessions. Individual results may vary.
- Do I need to use any special gels or creams? Specific instructions regarding conductive gels or creams will be provided in the detailed user manual. Always follow these guidelines for effective and safe treatment.