MYOSLIM EMSzero Body Sculpt Slimming Machine

Contents

EMSzero Body Shaping Device Instruction Manual

Model: EMSzero Body Sculpt Slimming Machine

Brand: MYOSLIM

1. Introduction

The EMSzero Body Shaping Device utilizes advanced High-Intensity Pulsed Electromagnetic (HI-EMT) and Radio Frequency (RF) technologies to effectively build muscle, reduce fat, and contour the body. This professional-grade equipment is designed for non-invasive body shaping treatments, offering an efficient alternative to traditional workouts.

EMSzero Body Shaping Device with 200Hz, 6500W, 15 Tesla specifications
Figure 1: EMSzero Body Shaping Device with key specifications (200Hz, 6500W, 15 Tesla).

The device works by inducing supramaximal muscle contractions, which are not achievable through voluntary exercise. This process forces muscle tissue to adapt, leading to increased muscle growth and simultaneous fat burning through lipolysis. The integrated RF technology further enhances fat breakdown and skin tightening.

Key Advantages:

  • Safe and non-invasive: No current, hyperthermia, radiation, or recovery period.
  • Efficient: 30 minutes of treatment is equivalent to 20,000-30,000 muscle contractions (e.g., belly rolls/squats).
  • Dual handles: Allows for simultaneous treatment of two areas or two individuals.
  • Zero consumables required.
  • Treats multiple body parts: Abdomen, buttocks, arms, thighs, and hamstrings.
  • Patented cooling system for long-time operation.
  • Progressive step training to optimize results.
  • 5 training modes: HIIT, Hypertrophy, Strength, Combo 1 (HIIT+Hypertrophy), Combo 2 (Hypertrophy+Strength).

2. Safety Information

Warnings:

  • All maintenance work must be performed by qualified after-sales personnel or technicians familiar with this instrument.
  • Before any maintenance, disconnect the power supply and unplug the device. Performing maintenance on a live device can cause personal injury and damage.
  • Avoid the ingress of harmful gases, corrosive liquids, and water into the instrument. Water ingress into the main unit is strictly prohibited to prevent reduced insulation performance, electrical leakage, and bodily harm.
  • The instrument contains precision electronic circuits. Avoid collisions and do not attempt to open it without authorization.

Notes:

  • During cleaning, prevent cleaning solutions from penetrating the instrument to avoid electrical leakage or corrosion of the USB port.
  • The entire device should be used in a dry, well-ventilated area and covered with a cloth when not in use.
  • Keep the instrument clean at all times. Use a soft, semi-dry cotton cloth for cleaning. Use 75% alcohol for cleaning; organic solvents like acetone are prohibited. Ensure cleaning solution does not enter the instrument. High-temperature sterilization should be avoided.

3. Product Components & Accessories

Product List:

Diagram of EMSzero device components including invisible light cover, forehead cushion, chin rest, logo, switch, and 21.5-inch tablet.
Figure 2: Main components of the EMSzero device, including the tablet and various parts.
  • Invisible Light Cover
  • Forehead Cushion
  • Chin Rest
  • Logo
  • Switch
  • 21.5-inch Tablet
  • View Capture Button
  • Light Source Switch Button
  • Power Cord Connector
  • Data Cable Interface

Accessories List:

Diagram showing the back of the tablet with USB data interface, HDMI data interface, switch, and power cord connector.
Figure 3: Back view of the tablet showing connection ports.
Item Quantity Image
Tablet Adapter 1 Piece
USB Cable 1 Piece
Host Power Cable 1 Piece ☑
Anti-light Neck Cloth 1 Piece
Instruction Manual 1 Portion V
Qualification Certificate 1 Portion

4. Setup Instructions

  1. Installation of the Tablet Stand Base

    Place the tablet stand into the slot of the base. Rotate the locking ring of the base 360 degrees to secure it.

  2. Installation of the Stand and Tablet

    Attach the assembled base stand to the back of the tablet. Tighten the four screws sequentially.

  3. Installation of Tablet Accessories

    Insert the tablet's power cable, USB connection cable, and the micro-hygrometer's USB interface into the bottom of the tablet stand. The tablet can be rotated 90 degrees during use.

  4. Installation of Host Hardware

    Insert the host's power cable and the other end of the USB cable into the back of the host.

    Rear view of the EMSzero device showing power and cable connections.
    Figure 4: Rear view of the EMSzero device with connection points.
  5. Powering On

    Connect the host's power cable and the tablet charger to a live electrical outlet. Press the power button at the bottom of the host. The indicator light turning on signifies that the device is powered. To turn it off, simply press the power button again or unplug the power cable from the outlet.

  6. Tablet Power Switch

    Swipe up from the bottom of any screen to find the power button. Tap to select it, then choose "Shut down" to turn off the device.

5. Operating Instructions

Initial Setup and Account Management:

  1. Network Connection

    After powering on, a network connection message will automatically appear. Click "Confirm" to select the appropriate network, then enter the password to establish the connection. Once connected, click the back button in the top right to return to the main interface.

  2. Account Registration and Login

    For first-time use, click the registration button to access the registration page. Fill in the required fields: username, phone number, verification code, password, and password confirmation. After completing the form, click "Register" to be redirected to the login interface and log in. Existing users can log in directly. (Note: Registered accounts are by default management accounts, allowing access to the backend for product entry, device management, and personnel management.)

    Screenshots of the EMSzero network connection and account registration/login interfaces.
    Figure 5: Network connection and account management screens.

Treatment Procedures:

  1. Selecting Treatment Mode

    From the home page, you can access four types of detection mode windows. Click "Start skin test" to access the client profile creation interface. Click "Add new client" in the bottom right, fill in client information, then click "OK" to access the capture interface. If you need to create new client profiles in batches, select "Client Management" in the bottom navigation bar and choose "Add new client".

  2. Skin Measurement Photography

    On the camera page, click the top right to select the face area to photograph (left face, right face, frontal face). Follow the voice prompts to position correctly, close your eyes, then click the capture button to start photographing. Once all required face areas are photographed, submit and upload for analysis. (Note: The domestic commerce version does not require skin tone selection; real and virtual contrast is used to compare positions of clients who have already been photographed.)

    Screenshot of the skin measurement photography interface.
    Figure 6: Skin measurement photography interface.
  3. Report Sharing and Printing

    In the top right corner of the full report page, click the share button to choose between obtaining the report via QR code or sending it by email. You can also select the print button to print the report.

  4. Humidity Detection

    To access the humidity analysis page from the skin analysis page, click the "Start detection" button. Follow the instructions to place the hygrometer flat against the corresponding facial skin area. Click the hygrometer capture button to obtain the humidity value. After completing detection for all four areas, click "Submit" to access the humidity analysis page.

    Screenshot of the humidity detection interface.
    Figure 7: Humidity detection interface.
  5. Microscopic / Scalp Examination

    Click "Microscopic / Scalp Examination" to access the capture mode. Select the area you need to photograph, then place the bottom of the portable microscope flat against the area you wish to capture. Click the capture button at the bottom of the screen or on the handle to take the photo. Wait for all three sets of light sources to complete the capture, then move to the next area to photograph.

  6. Case Recording

    On the imaging and spectral analysis page, clicking the icon on the right allows you to save the current image as a case. Select the department, test item, case category, treatment stage, and remarks description sequentially.

    Screenshot of the case recording interface.
    Figure 8: Case recording interface.

Applying Treatment Handles:

The EMSzero device comes with various handles for different body areas, including 4 RF handles and a pelvic stimulation pad. Secure the appropriate handle to the target area using the provided equipment band.

Image of a cushion handle for the EMSzero device.
Figure 9: Cushion handle for specific body areas.

The video below demonstrates the application of the handles and the treatment process.

Video 1: Demonstration of EMSzero device operation and handle application for body shaping.

6. Specifications

Attribute Value
Product NameEMS Body Slimming Machine
TechnologyHIEMT+RF 2 in 1 Slimming, High Intensity Pulsed Electromagnetic Body Sculpting
Power SupplyAlternating Current
Voltage50-1000V AC (110V / 220V options available)
MaterialABS
CertificationCE
Item TypeMassage & Relaxation
Operation MethodHandheld Type
FunctionsBody contouring, body slimming, body sculpt, muscle build, fat removal, skin tight, butt lift, muscle stimulation, EMS Cellulite Reductions, Weight Loss, Skin Tightening, Cellulite Reduction, Whitening, Skin Rejuvenation
Handles4/5 handles Optional (including RF handles and pelvic stimulation pad)
Target AreaBody, Legs/Arms, Hands, Abdomen, Hips, Waist, Back, Foot, Wrist, Chest, CORE, other
Training SiteWaist, ARMS, Legs, Muscle Relex Apparatus, Waist & Abdomen Exercise, head, Foot, BACK, Hand, Wrist, Hip, Chest, CORE, other
Type of SportsMuscle Relaxation
Technology AdvantageNon-invasive non-exercise healthy slimming
Plugs TypeAU, UK, EU, US, CN
ApplicationFor Commercial
Operation SystemEM Electromagnetic Sculpting

Electrical Parameters:

  • Input: 100~240VAC 50/60Hz
  • Frequency: 50/60Hz
  • Impedance: 50Ω
  • Output Power: 0~30W
  • Rated Current: 1A
  • Power Supply Voltage: 100~240VAC

The power cord used for this instrument must comply with national safety standards. It is imperative to use wall sockets or power strips equipped with standard, nationally certified wires to ensure operational safety.

7. Troubleshooting

This section addresses common issues you might encounter with your EMSzero device.

No. Issue Solution
1 The screen is not lit. The power button at the bottom of the screen is not turned on.
2 Humidity cannot be detected. The hygrometer's USB cable is not connected to the tablet.
3 WF/SF management does not produce a report. First, enter the corresponding weight or sleep duration data as per the page instructions.
4 Sun protection test is not performed. For sun protection testing, sun protection products must be applied and then photos taken.
5 Case - input point not found. On the right side of each analysis - Detection Indicator page.
6 The option to save the image in the Brush Tool function is not found. At the bottom of the comprehensive skin analysis report.
7 The voice cleaning window cannot be found. In the bottom navigation bar on the homepage, in the General Settings Management Center area.
8 How are products entered? Log in to the computer side on the website.

8. Warranty & Support

Warranty Coverage:

  • The host unit comes with a 1-year free warranty and long-term after-sales repair services.
  • During the warranty period, users are entitled to unified after-sales service and a policy for replacement of parts under warranty.
  • A valid warranty certificate for the machine purchase must be presented during maintenance. The warranty period starts from the instrument's shipping date from the factory.
  • If the same component and fault phenomenon reappear after repair, free maintenance is provided within 90 days.
  • Parts repaired or replaced during the warranty period belong to the after-sales maintenance network, while parts repaired or replaced after the warranty period belong to the user.
  • Additional services and gifts not configured by the factory by each regional distributor are supported by the distributor itself.

Exclusions from Warranty:

  • Free accessories and gifts of the X5PRO-AI intelligent skin image analyzer.
  • Damage caused by improper handling, use, maintenance, or storage by the user.
  • Damage caused by using a voltage below 100 volts or above 240 volts.
  • Damage resulting from use, maintenance, or care not in accordance with the product manual's instructions.
  • Disassembly or repair by personnel not affiliated with the after-sales service.
  • Unauthorized use of accessories or products provided by non-affiliated service personnel, leading to damage to the instrument or other problems.
  • Damage caused by force majeure (such as lightning, fire, earthquake, flood, and other natural disasters).
  • The product has exceeded its warranty period.
  • The model or number on the invoice or warranty card does not match the actual product.

In cases of non-warranty coverage, after-sales service personnel will perform paid repairs, including repair costs, parts costs, and on-site service fees. Specific fee standards comply with the provisions authorized by the competent services.

Warranty Card:

This warranty card must be filled out immediately after product purchase. Please keep the warranty card in a safe place. Please present valid proof of purchase during repair.

Support:

For further assistance, video technical support and 24-hour online service are available. Instructional operation video training is also provided.

A detailed user manual in PDF format is available for download: User manual (PDF)

9. User Tips

  • **Maximize Efficiency:** The EMSzero device offers a highly efficient workout, with 30 minutes of treatment equating to thousands of muscle contractions. Utilize this to achieve your body shaping goals effectively.
  • **Consistent Use:** For optimal results, follow the recommended treatment courses (e.g., 4 treatments within two weeks, each lasting half an hour) as suggested in the product description.
  • **Proper Placement:** Always ensure the treatment handles are correctly positioned and secured to the target body part using the provided bands for safe and effective stimulation.
  • **Explore Modes:** Experiment with the 5 different training modes (HIIT, Hypertrophy, Strength, Combo 1, Combo 2) to find what best suits your fitness goals and comfort level.
  • **Stay Informed:** Refer to the digital interface for real-time feedback and adjustments during your session.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.