1. General Information
The EMSzero series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
Advanced HI-EMT Technology
The EMSzero series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.
Touch-Controlled Display
The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.
Real-time Monitoring and Guidance
Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.
Upgradeability
As your therapeutic needs evolve, you may wish to upgrade your equipment later on. The EMSzero series offers flexible upgrade options to meet your future treatment requirements.
1.1 Indications for Use
EMSzero is intended for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMSzero instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
2. Safety Precautions and Warnings
Precautions Before Use:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Adjust to the lowest level initially, and then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation, and try to eat after one hour after the operation.
1.5 Contraindications:
Do not use this device if any of the following apply:
- Open wounds on the skin (or avoid wounds when using).
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer patients.
- Patients with infectious diseases.
- Pregnant women, lactating women, or during menstrual period.
- Major surgery patients, diabetic patients.
- Having any metal in the body.
- People with cerebrovascular disease (stroke patients).
1.6 Possible Side Effects:
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
Front view of the instrument:
Description: The front panel features a display screen and two EMS handles attached to the sides. A power button is located below the screen.
Description: A close-up of the touch screen interface, showing options for 'LIST', 'PATTERN', and 'RECORDS', with settings for intensity and time.
Note: The handle can only be used by the original machine and cannot be used interchangeably.
Magnetic thin handle plug:
Description: The rear panel shows the connections for the handles, a fuse, and the power plug. The handles are connected via flexible hoses.
3.2 Handle Options
The machine supports various handle configurations:
- 2 Handle RF:

- 4 Handle RF:

- 5 Handle RF:

3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 (or more, depending on model) | ![]() |
| 3 | Belts ($8*80CM, $8*90CM, $8*100CM) | 3 | |
| 4 | Power cable | 1 | |
| 5 | Electronic manual | 1 copy |
4. Device Installation
-
Install the Handle Bracket
Use a screwdriver to install the handle brackets on both sides of the machine. Align the hole and fasten the clip.
-
Handle Film Application
Stick the black film to the working part of the handle.
-
Handle Installation
Lock the key ring to secure the handle.
-
Connect Power
Connect one end of the power cord to the machine and plug the other end into the main socket. Do not connect multiple machines to the same socket.
-
Press on the Back Switch
Ensure the power is off (light not on) before proceeding.
-
Press the Front Switch
Single-click the front switch to power on. Long press to power off.
5. Basic Device Operation
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced.
Warning: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls
5.3.1 Setting the Therapy by Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:
- List: Navigation controls.
- Pattern: Channels selector.
- Records: Records of previous treatments.
- Play/Pause Button: Start/pause therapy.
- Up/Down Arrows: Setting up therapy parameters (e.g., intensity, energy).
5.4 Unit Settings
The device offers various settings for customization:
Description: The screen displays options for language selection, including English, Japanese, Korean, Portuguese, Spanish, French, Russian, and Simplified Chinese.
-
Language Settings
Select your preferred language from the available options on the screen.
-
Sound Adjustment
Adjust the device's sound volume.
-
Brightness Adjustment
Adjust the screen brightness for optimal visibility.
-
Set Date and Time
Configure the current date and time on the device.
-
System Adjustment
Access and modify general system settings.
-
Technician Access
This section is for authorized technicians and requires a password.
Note: Adjust the corresponding intensity/stage frequency/time according to different customer needs. Click the start/pause work button to enter the operation work. If the customer requests to pause, they can click the start/pause work button to pause the work, and after the work is completed, they can directly click the return key to return.
6. Therapy
6.1 Preparing for Therapy
- Communicate with patients.
- Ensure good health.
- Stay hydrated.
- Wear appropriate clothing.
- Avoid eating in large quantities.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol.
6.2 Placing the Handle
Proper placement of the handles is crucial for effective treatment. Refer to the diagrams below for guidance:
Abdomen
Buttocks
Arm
Thigh
Calf
Pelvic Floor (Arse)
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
7. Maintenance and Repair
7.1 Maintenance
7.1.1 Daily Inspection
Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
7.1.2 Cleaning
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off.
7.1.3 Replacing the Fuse
When replacing the fuse, in order to prevent electric shock, please turn off the power and unplug the power plug.
7.2 Repair
After purchasing the instrument, you need to fill in the warranty card and send it to the manufacturer or agent to have the effect of warranty. From the date of the purchase of the instrument, if a product quality problem belonging to the company occurs, then a free warranty is promised for one year (Warranty needs warranty card and purchase bill, and the scope of warranty here is limited to the instrument host, excluding accessories and other consumables that need to be replaced regularly). After the warranty period has expired, please contact the manufacturer directly to provide paid after-sales service. To repair the machine, you must contact the company's business department or dealer, and do not repair it without authorization. Any unpacking without consent will not be guaranteed by our company.
8.3 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole, wipe with pure cotton material.
8.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room, the packaging box should be padded. The ambient temperature should be -10°C ~ 40°C, the relative humidity should not be greater than 93%, and it is not allowed to be placed in harmful gases, around flammable, explosive substances and corrosive gases.
Transportation: The instrument under the packaging condition is suitable for road, railway, air and water transportation. During loading, unloading and transportation, it should prevent severe vibration and shock, and should not be affected by moisture, and should not be mixed with flammable and corrosive substances, and the specific requirements are specified in the order contract.
8.5 Term of Use
- The warranty period of this instrument is 1 year (note: man-made damage is excluded).
- The warranty period for accessories is 3 months (note: man-made damage is excluded).
- The continued use of the instrument beyond the service period shall be subject to the approval of the engineer, and the engineer shall conduct a performance test of the instrument periodically in the subsequent use.
- Scrap instruments and accessories beyond their useful life should be disposed of according to local regulations.
8.6 Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | Power plug is not inserted into the socket, Power switch not on, Power fuse failure | Check the power, Check the power switch, Replace the fuse |
| Handle not working | Check the handle for loose connection | Reseat the handle |
9. Technical Parameters
| Item | Value |
|---|---|
| Name | EMSzero |
| Input Power Supply | AC110V-220V 50/60Hz |
| Output Maximum Power | 0-6500W |
| Frequency | 5-200Hz |
| Screen Size | 15 inches |
| Machine Color | White/Black |
| Target Area | Body, Legs/Arms, Hands |
| Application | For Commercial |
| Technology | EMS Electrical Muscle Stimulation, High Intensity Pulsed Electromagnetic |
| Operation System | EMS Electromagnetic Sculpting |
| Material | ABS+Stainless Steel |
| Cooling System | Intelligent air cooling system |
| Operation Mode | Manual Mode + Automatic Mode |
| Plugs Type | AU, EU, US, CN, JP, Other |
| Certification | CE |
9.1 Electromagnetic Compatibility (EMC)
Radiated Electromagnetic Field Immunity Test:
| Parameter | Value |
|---|---|
| Port | Enclosure |
| Basic Standard | IEC 61000-4-3:2020 |
| Test Level | 30V/m with 80% AM. 1kHz Modulation. |
| Standard Requirement | A |
| Tester | Sam Liu |
| Temperature | 25°C |
| Humidity | 54% |
Test Equipment:
| Description | Manufacturer | Model | Identifier | Cal. Date | Cal. Due |
|---|---|---|---|---|---|
| Signal Generator | IFA | 2023B | N/A | 15/03/2022 | 14/03/2023 |
| Power Amplifier | AR | 150W1000 | N/A | 15/03/2022 | 14/03/2023 |
| Power Antenna | AR | 25S1G4A | N/A | 15/03/2022 | 14/03/2023 |
Block Diagram of Test Setup:
Description: The diagram illustrates a 7x4x3 chamber with EUT (Equipment Under Test) & Support, Power Amp, Signal Generator, PC Controller, and a Contro Room for monitoring.
10. Warranty and Support
Warranty Card Information:
- The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Maintenance and updates can be provided, with appropriate fees charged. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year.
- Free warranty service is not provided for the following user's failures caused by personal reasons:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
For after-sales service, please contact the manufacturer's business department or dealer. Do not repair the machine without authorization.
Manufacturer: Guangzhou Xinwei Electronic Technology Co., Ltd.
Service: ODM/OEM/Dedicated online service, Online support, Video technical support.
User Tips
Video Description: A demonstration of the EMSzero MYOslim machine's operation, including powering on, navigating the touch screen interface to adjust settings like intensity and energy, and applying the handles to different body areas such as the abdomen and legs for treatment.
- Consistency is Key: Users report seeing tangible results after the first treatment, with significant improvements typically observed two to four weeks after the last session. Maximum results often peak at 3 months.
- Follow Treatment Cycles: For optimal results, adhere to the recommended treatment cycles. Studies suggest that after an initial series of 4 sessions, muscle results can last a year or more, and fat loss results are permanent.
- Proper Handle Application: Ensure handles are securely placed on the target area (abdomen, buttocks, arms, thighs, calves, pelvic floor) as shown in the diagrams for effective muscle stimulation.
- Adjust Intensity Gradually: Always start with the lowest intensity and gradually increase it based on your comfort and tolerance to avoid discomfort.
- Stay Hydrated: Proper hydration is important for overall well-being and can support the body's response to muscle stimulation.
- Consult the PDF Manual: For more detailed instructions and specific operational procedures, refer to the comprehensive user manual available in PDF format. View User Manual (PDF).