1. Safety Precautions
This manual provides detailed information on the functions, installation, and operation of this product. Please read it carefully before installation and use to ensure proper usage and avoid potential hazards.
1.1 General Precautions
- This product should only be used under specified conditions to prevent damage.
- Do not expose the product to rain or moisture.
- To prevent electric shock, do not open the case. Installation and maintenance should only be performed by qualified technicians.
- Do not use the product outside its specified temperature, humidity, or power supply ranges.
- Use a soft dry cloth to clean the camera. For heavy dirt, use a diluted neutral detergent. Avoid solvents, which may damage the surface.
1.2 Electrical Safety
Installation and use must strictly comply with local electrical safety standards.
1.3 Transportation
Avoid stress, vibration, or moisture during transportation, storage, installation, and operation.
1.4 Do Not Dismantle Camera
The manufacturer is not responsible for any unauthorized modification or dismantling of the product.
1.5 Magnetic Interference
Electromagnetic fields at specific frequencies may affect the video image. This product is Class A and may cause radio interference in household applications. Appropriate measures are required.
2. Product Overview
The SMTAV 20X 4K UHD PTZ Camera offers superior performance with rich interfaces and advanced ISP processing algorithms. It delivers vivid images with a strong sense of depth, high resolution, and fantastic color rendition. The camera supports H.265/H.264 encoding, ensuring fluent and clear motion video even in challenging bandwidth conditions.
2.1 Key Features
- UHD Image: Employs a 1/2.8 inch 8.42M high-quality CMOS sensor, providing resolutions up to 3840x2160 at 30 fps.
- Leading Auto Focus Technology: Advanced autofocus algorithm ensures swift, accurate, and stable focusing.
- Low Noise High SNR: Low noise CMOS and 2D&3D noise reduction technology minimize noise without compromising image quality.
- Multi Video Outputs: Supports HDMI, 3G-SDI, USB3.0, and wired LAN (PoE+ optional).
- Multi Audio Video Compression Standards: Supports H.265/H.264 video compression and AAC audio compression, with up to 1920x1080 resolution at 60 frames/second.
- Audio Input: Supports AAC and 48000 sampling frequency.
- Multiple Network Protocols: Supports ONVIF, GB/T28181, RTSP, RTMP, and NDI protocols, including RTMP push mode for streaming media servers and RTP multicast mode.
- Multiple Control Protocols: Supports VISCA, PELCO-D, PELCO-P protocols with automatic identification.
- Super Quiet PTZ: High-precision stepping motors ensure smooth, low-speed pan/tilt movements.
- Low-power Sleep Function: Supports low-power sleep/wake-up, consuming less than 400mW in sleep mode.
- 255 Presets Positions: Up to 255 presets (10 via remote control).
- Various Remote Controls: Supports IR remote control and 2.4G wireless remote control, unaffected by angle or distance.
- Wide Application: Ideal for remote education, teaching, broadcasting, conference systems, remote training, telemedicine, courtroom systems, and emergency command systems.
2.2 Product Dimensions
Figure 2-1: Diagram showing the dimensions of the SMTAV 4K UHD PTZ Camera. Dimensions are approximately 253.5mm (L) x 144mm (W) x 169mm (D).
3. Setup
3.1 Unpacking and Accessories
Upon unpacking, verify that all the following accessories are included:
| Item | Configuration | Accessory |
|---|---|---|
| Accessory | Standard | Power Adapter |
| User Manual (PDF available online) | ||
| IR Remote Control | ||
| Optional | Brackets for Wall Mounting | |
| Brackets for Ceiling Mount |
A detailed user manual in PDF format is available for download: View User Manual (PDF)
3.2 Physical Installation
When using the camera, ensure the plastic pad is placed on the center bottom of the device for stability.
3.2.1 Wall Mount Installation
Default bracket installation supports ceiling mounting and vertical wall mounting on surfaces like formwork or concrete. It cannot be installed on gypsum board.
Figure 1-2: Step-by-step diagram for wall mounting the PTZ camera using the provided bracket, screws, nuts, and gaskets.
3.2.2 Ceiling Mount Installation
Figure 1-3: Step-by-step diagram for ceiling mounting the PTZ camera using self-tapping screws, rubber plugs, and the ceiling cover.
3.3 Initial Power-on Self-Test
Connect the device to a power socket using the DC12V power adapter. After power-on, the receiver light will flash, and the camera will perform a brief pan-tilt tour before returning to the home position. The self-test is complete when the light stops flashing. If Preset 0 is configured, the camera will automatically move to that position after the self-test.
3.4 Interface Introduction and Connections
The camera features various interfaces for video output, audio input, and control.
Figure 1-1: Rear view of the camera highlighting the USB, HDMI, 3G-SDI, Audio In, RS232/RS485, LAN, DC12V Power, and Power Switch interfaces.
Figure 2-2: Detailed diagram illustrating connections for USB 3.0, HDMI, 3.5mm Audio In, RS485/RS422, LAN, and 3G-SDI interfaces, along with power connections.
3.4.1 Network Output
- Connect the camera to your network via the LAN port.
- Access the Web Interface by typing the camera's IP address (default: 192.168.5.163) into a web browser.
- Log in with username "admin" and password "admin" (default).
- The Web Interface allows PTZ control and configuration settings.
- Note: If you forget your username, password, or IP address, press the remote control combination keys [*] [#] [Manual] to reset them to default.
3.4.2 HDMI Output
- Connect the camera to a display device using an HDMI cable.
3.4.3 USB3.0 Output
- Connect the camera to a computer's USB 3.0 port.
- Open video software and select the camera as the image device to output video.
3.4.4 3G-SDI Output
- Connect the camera to a display device using a 3G-SDI cable.
4. Operation
4.1 Remote Control Usage
The camera can be controlled using either the IR remote control or a wireless remote control. The buttons and usage methods are identical for both.
Image of the IR remote control for the SMTAV PTZ Camera.
4.1.1 Wireless Remote Control Pairing
- Code Pairing: Press "Settings" + "*" for 3 seconds. The LED will flash, then remain off if pairing is successful. If unsuccessful, the red LED flashes for 20 seconds.
- Clear Code Data: Press "Settings" + "#" from off to flashing. Power cycle the receiver. The LED will be off, indicating data cleared.
- Sleep Mode: The remote enters sleep mode if inactive. Press any key to wake up.
4.1.2 IR Remote Control Functions
- Standby Key: Long press (3s) to enter/exit standby mode.
- Camera Address Selection: Select the camera address to control (1-4).
- Number Key (0-9): Set or run presets.
- Focus Control Key: Auto Focus, Manual Focus (+/-).
- Zoom Control Key: Zoom In (+), Zoom Out (-).
- Set/Clear Preset Key: Set preset (Set + 0-9), Clear preset (Clear + 0-9).
- Pan/Tilt Control Key: Up, Down, Left, Right arrows. "HOME" key returns to center or enters next menu level.
- BLC Control Key: Turn Back Light Compensation ON/OFF.
- Menu Setting: Open/close OSD menu, enter/exit menu, or return to previous menu.
- Camera IR Remote Control Address Setting: Use [*] + [#] + [F1-F4] for addresses 1-4.
- Key Combination Functions: Various combinations for clearing presets, flip switch, menu language, aging mode, restoring defaults, and video format switching.
- Tracking Mode Setting: Use [*] + [#] + [F1-F4] to turn off/on tracking, real-time tracking, or switch tracking target.
4.2 Menu Settings (OSD Menu)
In normal working mode, press the MENU key to display the OSD menu. Use scroll arrows to navigate and select items.
4.2.1 Main Menu Options
- Language: Chinese/English.
- Monocular Tracking: Enter submenu for monocular tracking settings (ON/OFF).
- Setup: Enter submenu for system settings (Protocol, Visca Address, Baud Rate, Auto Flip, Prompt).
- Camera: Enter submenu for camera parameter settings (Exposure, Color, Image, Focus, Noise Reduction, Style).
- P/T/Z: Enter submenu for Pan/Tilt/Zoom settings (Speed by Zoom, Zoom Speed, Image Freezing, Acc Curve, Preset Speed, PTZ Speed, Preset Lock, Preset Zoom Speed, L/R Direction).
- Video Format: Select video output format (e.g., 4KP30, 1080P60, 720P60).
- Network: Enter submenu for network settings (DHCP, IP Addr, Subnet Mask, Gateway).
- Version: Display MCU, Camera, and AF versions.
- Restore Default: Select Yes/No to restore factory defaults (language, color, video format not restored).
4.3 Web Interface Usage
The camera's web interface provides comprehensive control and configuration options.
4.3.1 Web Login
- Enter the camera's IP address (default: 192.168.5.163) in a web browser.
- Login as administrator (default username/password: admin) for full control, or as a standard user (user1/user2) for preview and basic operations.
- Language selection: "中文|English" option available.
4.3.2 Preview
After logging in, the video preview interface allows PTZ control, zoom, focus, sound, full screen, and preset management.
4.3.3 Monocular AI Tracking Function Web Page Configuration
Enable tracking in the management interface. In the PTZ control area, you can set up to 4 regional tracking presets. Each view for area tracking must be continuous and overlap when setting presets.
Figure 4-3: Diagram illustrating the setup of regional tracking for the AI tracking function, showing how to define continuous and overlapping regions.
4.3.4 Configuration
The configuration section includes settings for audio, video, network, and system parameters.
- Audio Configuration: Enable/disable audio, set compressing format (default AAC), sampling frequency (default 48000), sampling precision (default 16bits), code rate, channel type, and input volume.
- Video Configuration: Set code stream, compression format (H.264/H.265), profile, video size, stream rate control, image quality, bit rate, frame rate, key frame interval, and minimum QP.
- Network Configuration: Configure network ports (Data, Web, Onvif, Soap, RTMP, RTSP, Visca, Https, WebSocket), Ethernet parameters (DHCP, IP Address, Subnet Mask, Gateway), and DNS settings.
- System Configuration: Device properties (name, ID, language), system time (date format, separator, time zone, NTP), user management (admin, user1, user2 passwords), and version update.
4.4 Serial Port Communication
The camera can be controlled via RS232/RS485 (VISCA IN) cable. The RS232 parameters are: Baud rate (2400/4800/9600/115200/second), 1 Start Bit, 8 Data Bits, 1 Stop Bit, No Verification Bit.
4.4.1 VISCA Protocol List
The manual provides detailed VISCA protocol commands for various camera functions, including Ack/Completion messages and Error messages.
4.4.2 Camera Control Commands
Specific commands are listed for AddressSet, IF_Clear, Power ON/OFF, Zoom (Tele/Wide, Direct), Focus (Auto/Manual, Direct), WB (Auto/Manual, One Push), AF Sensitivity, AF Zone, R/B Gain, AE Mode, Shutter, Iris, Gain Limit, Brightness, ExpComp, Back Light, WDR Strength, NR, Gamma, Low-Light Mode, Preset Speed, Flicker, Aperture, Picture Effect, Memory, SYS Menu, IR Receive, Setting Reset, Color Saturation, ID Write, Flip, Video System, and Pan-tilt Drive.
4.4.3 Inquiry Commands
Commands for inquiring about Power status, Zoom/Focus position, AF Mode/Sensitivity/Zone, WB Mode/Sensitivity, R/B Gain, AE Mode, Shutter/Iris position, Gain Limit, Brightness, ExpComp Mode/Position, Backlight Mode, WDR Strength, NR Level, Flicker Mode, Aperture, Picture Effect, Memory, SYS Menu, LR Reverse, Picture Flip, Color Saturation, ID, IR Receive, Gamma, and Video System.
4.4.4 Pelco-D and Pelco-P Protocol Command Lists
Detailed command lists are provided for Pelco-D and Pelco-P protocols, covering Pan/Tilt movements, Zoom, Focus, Set/Clear/Call Presets, and Query functions.
5. Specifications
5.1 Camera Lens Parameters (20X Model)
| Parameter/Model | 20X |
|---|---|
| Image Sensor | 1/2.8 inch high quality UHD CMOS sensor |
| Effective Pixel | 8.42 megapixel, 16:9 |
| Video Signal (HDMI) | 4KP30, 4KP25, 1080P60, 1080P50, 1080P30, 1080P25, 720P60, 720P50, 1080P59.94, 1080P29.97, 720P59.94 |
| Video Signal (SDI) | 1080P60, 1080P50, 1080P30, 1080P25, 720P60, 720P50, 1080P59.94, 1080P29.97, 720P59.94 |
| Video Signal (USB3.0 UVC) | 1920x1080 / 1280x720 / 1024x576 / 800x600 / 800x448 / 640x360 / 640x480 / 480x270 / 320x180 @30/25/20/15/10/5fps |
| Video Signal (MJPG/H264/H265) | 3840x2160 / 2560x1440 / 1920x1080 / 1600x896 / 1280x720 / 1024x576 / 960x540 / 800x600 / 800x448 / 720x576 / 720x480 / 640x360 / 640x480 / 480x270 / 352x288 / 320x240 @30/25/20/15/10/5fps, 1920x1080 |
| LAN Main Stream (H264/H265) | 1920x1080 / 1280x720 / 640x360 / 640x480 @30/25/20/15/10/5fps |
| LAN Sub-stream (H264/H265) | 1920x1080 / 1280x720 / 640x480 / 320x240 @30/25/20/15/10/5fps |
| Focal Length | f=5.05~101mm |
| Viewing Angle | 3.45°(N) ~ 60.7°(W) |
| Iris | F1.8 ~ F2.9 |
| Digital Zoom | 16X |
| Minimum Illumination | 0.5Lux (F1.8, AGC ON) |
| DNR | 2D & 3D |
| White Balance | Auto/Manual/One-push/Specified Temperature 2400K-7100K |
| Focus | Auto/Manual/One-push |
| Electronic Shutter | Auto/Manual |
| BLC | On/off |
| Dynamic Range | Off/dynamic level adjustment |
| Video Adjustment | Brightness, Contrast, Sharpness, Horizontal Flip, Vertical Flip (display when auto flip off), BW Mode, Gamma Curve, Electronic Zoom, DCI |
| SNR | >55dB |
5.2 Interface Parameters
| Interface Parameter | Details |
|---|---|
| Interfaces | HDMI, USB3.0, 3G-SDI, LAN (Support POE+), A-IN, RS232-IN, RS485-IN, DC12V Power Switch. |
| Video Output | HDMI, 3G-SDI, LAN, USB3.0 |
| Image Data Stream | Dual Stream Output |
| Video Compression Format | LAN: H.264, H.265; USB 3.0: MJPG, H264, H265, YUY2, NV12 |
| Audio Input Interface | Double track 3.5mm linear input; |
| Audio Output Interface | HDMI, 3G-SDI, LAN, USB3.0 |
| Audio Compression Format | AAC |
| LAN Interface | 100M Ethernet port, optional POE+ power supply, supports audio and video output |
| Network Protocol | RTSP/RTMP, ONVIF, GB/T28181, NDI (Optional); Support network VISCA control protocol; Support remote upgrade, remote restart, remote reset |
| Control Interface | RS232-IN, RS485 |
| Serial Port Communication Protocols | VISCA/Pelco-D/Pelco-P; Support Baudrate: 115200/38400/9600/4800/2400 |
| USB Communication Protocol | UVC (Video Communication Protocol) |
| Power Supply | HEC3800 Power Socket (DC12V); Input: AC110V~AC220V; Output: DC12V/1.5A |
| Input Voltage | DC12V±10% |
| Input Current | <1.36A |
| Consumption | <16W |
5.3 PTZ Parameters
| PTZ Parameter | Details |
|---|---|
| Pan Move | -170° ~ +170° |
| Tilt Move | -30° ~ +30° |
| Pan Speed | 0.1°/s ~ 100°/s |
| Tilt Speed | 0.1°/s ~ 45°/s |
| Preset Speed | Pan: 100°/s, Tilt: 45°/s |
| Preset Quantity | Up to 255 preset (10 via remote control) |
5.4 Other Parameters
| Other Parameter | Details |
|---|---|
| Storage Temperature | -10°C ~ +60°C |
| Storage Humidity | 20% ~ 95% |
| Working Temperature | -10°C ~ +50°C |
| Working Humidity | 20% ~ 80% |
| Dimension (L×W×D) | 253.5mm × 144mm × 169mm |
| Weight | 1.46kg |
| Environment | Indoors |
6. Maintenance
- Power Disconnection: Disconnect power if the camera will not be used for a long period.
- Cleaning the Case: Use a soft cloth or cotton to wipe dust. For stains, use a mild detergent. Avoid strong or corrosive detergents.
- Cleaning the Lens: Use a dry soft cloth. For persistent stains, use a mild detergent.
7. Troubleshooting
7.1 No Image on Video Output
- Check if the device is properly powered and if the power indicator is lit.
- Power cycle the device to verify normal self-test.
- Inspect video output and display cables for integrity.
7.2 Intermittent Image Display
- Inspect video output and display cables for integrity.
7.3 Image Shake During Lens Zoom
- Verify the device is securely mounted.
- Check for nearby machinery or objects causing vibration.
7.4 Remote Control Unresponsive
- Test if the remote functions when set to address 1 (reset device to factory defaults to restore remote address to 1).
- Verify remote control batteries are properly installed or sufficiently charged.
- Ensure the OSD menu is not active. The menu will automatically exit after 30 seconds, allowing control.
7.5 Serial Port Cannot Be Controlled
- Verify if the control cable is the company's standard configuration.
- Check if the serial device protocol, baud rate, and address match the device specifications.
- Inspect whether the control cable is properly connected.
7.6 Web Page Cannot Be Logged Into
- Use a monitor to verify if the device is outputting images normally.
- Check if the network cable is properly connected (a flashing yellow indicator light on the network port indicates a valid connection).
- Verify the computer is on the same subnet as the device and that the subnet matches the device's IP address.
- On the computer, open "Start," select "Run," enter "cmd," and click 'OK' to open the DOS command window. Enter "ping 192.168.5.163" and press Enter. If the information shown in Figure 6-1 appears, it indicates a network connection.
Figure 6-1: Screenshot of a successful network connection test via command prompt, showing replies from the camera's IP address.
8. User Tips
- For optimal AI tracking performance, ensure the camera's field of view is clear and the subject is well-lit.
- When configuring network settings, always save changes and restart the device for them to take effect.
- If experiencing control issues, verify the remote control's battery and ensure no OSD menu is active on the display.
9. Statement of Compliance
9.1 Disclaimer
⚠️ Camera products can only be used for purposes permissible under applicable law and regulations. Misuse of the product for any illegal activities is strictly forbidden. Please comply with the applicable laws and regulations in your country/area.