1. Introduction and Overview
The PowMr POW-LVM5K series is an advanced all-in-one solar charge inverter designed for mixed solar energy storage. It integrates solar energy storage, municipal power charge storage, and AC sine wave output. Utilizing DSP control and an advanced control algorithm, it offers high response speed, reliability, and industrial-grade performance.
This inverter supports four charge modes: only solar power, mains power priority, solar energy priority, and mixed charge. It also offers two output modes: inverting and mains power, catering to diverse application needs.
The solar charge module incorporates the latest optimized MPPT tracking technology, ensuring real-time maximum power point tracking of the photovoltaic array across a wide voltage range, maximizing energy harvest from solar panels.
The AC-DC charge module features a full digital double closed-loop control of voltage and current, providing high control accuracy and a compact design. It ensures stable and reliable battery charging and protection with a wide AC voltage input range and comprehensive input/output protection.
The DC-AC inverter module, based on full digital intelligent design, uses advanced SPWM technology to output pure sine wave, converting DC to AC. It is suitable for various AC loads including household appliances, electric tools, industrial devices, and electronic audiovisual equipment. The segment LCD displays real-time system data and operational status, while comprehensive electronic protection functions ensure overall system safety and stability.
1.1 Package Contents
The package of the POW-LVM5K-48V-N solar inverter includes:
- Inverter unit
- Set of screw accessories
- Pair of terminals
- User manual (this document)
- Warranty card
Video 1: Unboxing and overview of the PowMr POW-LVM5K-48V-N solar inverter, highlighting included accessories, output power, input voltage range, MPPT controller, and safety features.
1.2 Key Features
- Full digital voltage and current double closed-loop control with advanced SPWM technology for pure sine wave output.
- Two output modes: mains bypass and inverter output for uninterrupted power supply.
- Four optional charge modes: only solar energy, mains priority, solar energy priority, and mixed charge.
- Advanced MPPT technology with efficiency up to 99.9%.
- Wide MPPT voltage range.
- Lithium battery activation function via solar energy and AC mains power, supporting lead-acid and lithium batteries.
- LCD screen and 3 LED indicators for dynamic display of system data and operation states.
- ON/OFF rocker switch for AC output control.
- Power saving mode to reduce no-load loss.
- Intelligent adjustable speed fan for efficient heat dissipation and extended system life.
- Multiple protection functions and 360° comprehensive protection, including short circuit, overvoltage, undervoltage, overload, and back filling protection.
- Mixed load function: allows photovoltaic and commercial power to supply the load simultaneously when the battery is not connected (commercial power must be connected), or when the battery is full to maximize photovoltaic energy utilization.
Figure 2: Key features of the 5000W Off-Grid Solar Inverter.
2. Important Safety Instructions
Please read all instructions and precautions in this manual carefully before installation and use. Save these instructions for future reference.
- Non-safety voltage exists inside the all-in-one solar charge inverter. Do not disassemble the inverter yourself. Contact professional maintenance personnel for repairs.
- Keep the inverter out of reach of children.
- Do not install the inverter in harsh environments (moist, oily, flammable, explosive, or heavily dusty areas).
- The mains input and AC output are high voltage; do not touch wiring terminals.
- The inverter housing can be hot during operation; avoid touching it.
- Do not open the terminal protective cover while the inverter is operating.
- It is recommended to attach a proper fuse or circuit breaker to the outside of the inverter.
- Always disconnect the fuse or circuit breaker near the PV array, mains, and battery terminals before installing or adjusting wiring.
- After installation, ensure all wire connections are tight to prevent heat accumulation due to poor connection.
- This all-in-one solar charge inverter is off-grid. Confirm it is the sole input device for the load. Do not use it in parallel with other AC power sources to prevent damage.
- Take care when installing the battery. Wear goggles when handling lead-acid liquid batteries. Wash any skin contact with battery acid immediately with clear water.
- Do not place metal objects near the battery to prevent short circuits.
- Ensure good ventilation around the battery to dissipate acid gas generated during charging.
- During cabinet installation, reserve sufficient space around the inverter for heat dissipation. Do not install the inverter and lead-acid liquid battery in the same cabinet to avoid corrosion from acid gas.
- Only charge batteries consistent with the inverter's type.
- Loose connections or corroded wires can cause excessive heat, melting insulation, burning materials, or fire. Ensure all connectors are tightened and wires are secured with ties to prevent loosening from vibration.
- Select tie conductors with a current density no greater than 5A/mm².
- Outdoor installations must be protected from direct sunlight and rain.
- Even when the power switch is off, high voltage may remain inside the inverter. Do not open or touch internal components until capacitors are fully discharged.
- Do not reverse the polarity of the battery input, as this can damage the device.
- AC supply input and AC output are both high voltage; do not touch the wires.
- Do not touch the fan during operation to prevent injury.
3. Setup and Installation
3.1 Select the Mount Location
Confirm the installation position and ensure adequate heat dissipation space. The inverter should be mounted on a wall surface.
Ensure sufficient airflow through the cooling fins. Reserve at least 200mm space at the left and right air outlets for natural convection heat loss.
Figure 3: Intelligent variable speed fan for efficient heat dissipation.
WARNING: Danger of explosion! Never install the all-in-one inverter and lead-acid liquid battery in the same sealed space or in a sealed place with probable accumulation of battery gas.
3.2 Mount the Inverter
Install the unit by screwing two M6 screws into the mounting holes. Refer to the dimension drawing for precise measurements.
Figure 4: Product Overview with labeled components and mounting holes.
3.3 Preparation for Wiring
Before connecting all wirings, remove the bottom cover by unscrewing the two screws as shown in the product overview diagram (Figure 4).
3.4 Wiring Specification and Breaker Type
Observe national and local electrical specification requirements for wiring and installation. The wire diameter and breaker type are for reference; select appropriate components based on practical conditions.
3.4.1 PV Input Wiring
The minimum wire diameter for the photovoltaic array is calculated based on its short circuit current. The PV array's short circuit current should not exceed the maximum input current of the PV.
| Model | Wire Diameter | Max. PV Input Current | Circuit Breaker Spec |
|---|---|---|---|
| POW-LVM5K-48V-N | 6mm²/10AWG | 22A | 2P - 25A |
Note: The voltage in series shall not exceed maximum PV input open-circuit voltage.
Before wiring, disconnect the external breaker. Connect PV input wires according to the cable sequence and terminal position. PV+: positive input pole, PV-: negative input pole.
3.4.2 AC Input/Output Wiring
Before AC input/output wiring, disconnect the external breaker and confirm the cable thickness. Connect AC input wires according to cable sequence and terminal position: Ground, Live (L), Neutral (N).
| Model | Wire Diameter | Max. Bypass Input Current | Circuit Breaker Spec |
|---|---|---|---|
| POW-LVM5K-48V-N | 10mm²/7AWG | 63A | 2P - 63A |
Note: A corresponding breaker is already present at the mains supply input connection point; no additional breaker is needed.
For AC output, connect wires according to cable sequence and terminal position: Ground, Live (L), Neutral (N).
| Model | Wire Diameter | Rated Inverter AC Output Current | Max. Bypass Output Current | Circuit Breaker Spec |
|---|---|---|---|---|
| POW-LVM5K-48V-N | 10mm²/7AWG | 42A | 63A | 2P - 63A |
Note: The wire diameter is for reference. For long distances between the PV array/inverter and battery, use thicker wire to reduce voltage drop.
3.4.3 Battery Wiring
Before wiring, disconnect the external breaker. Ensure the cable is thick enough. BAT wires should be connected via O-shaped terminals (recommended 6mm inside diameter). Compress the BAT wire firmly to prevent excessive heating.
| Model | Wire Diameter | Rated Battery Discharge Current | Max. Charge Current | Circuit Breaker Spec |
|---|---|---|---|---|
| POW-LVM5K-48V-N | 33mm²/2AWG | 125A | 80A | 2P - 200A |
Connect BAT wires according to cable sequence and terminal position: BAT+: positive battery pole, BAT-: negative battery pole.
WARNING: Input from mains supply, AC output, and photovoltaic array may generate high voltage. Before wiring, ensure the breaker or fuse is open. During wiring, do not close the breaker or fuse. Ensure '+' and '-' poles are correctly connected. A breaker must be installed at the battery end. Disconnect the breaker before wiring to prevent electric sparks. Avoid battery short circuits. If the inverter is in a thunder-prone area, install an external arrester at the PV input terminal.
3.5 Final Assembly
After wiring, inspect all connections for correctness and tightness. Verify positive and negative input poles of the battery and PV, and ensure AC input is not incorrectly connected to the AC output terminal. Once wiring is confirmed reliable and correct, install the terminal protection cover.
Figure 5: Comprehensive wiring connection diagram.
3.6 Start Up the Inverter
- First, close the breaker at the battery end. Then, press the rocker switch at the lower left side of the machine to the "ON" state. The "AC/INV" indicator light will flash, indicating normal inverter operation.
- Next, close the breakers of the photovoltaic array and mains supply.
- Finally, once AC output is normal, turn on AC loads one by one. This prevents protection actions caused by a large instantaneous impact from simultaneously turning on all loads. The inverter will operate normally according to the set mode.
NOTICE:
- If power is supplied to different AC loads, it is suggested to turn on loads with high impact current first, then turn on loads with low impact current after the first loads operate stably.
- In case of abnormal operation or display (LCD or indicator light), refer to the "Troubleshooting" section to resolve issues.
4. Operating Modes
4.1 Charge Modes
- Photovoltaic Priority: Mains charge starts only when photovoltaics are not working. Maximizes solar energy use during the day and uses mains for charging to maintain battery levels. Suitable for areas with stable power grids and high electricity prices.
- Mains Supply Priority: Mains supply charges the battery preferentially. Photovoltaic charging starts only when mains supply is unavailable.
- Mixed Charge: Prioritizes photovoltaic MPPT charging. If solar energy is insufficient, mains supply supplements. If solar energy is sufficient, mains charging stops. This mode offers the fastest charging and is suitable for areas with unstable power grids, ensuring sufficient backup power.
- Only Solar: Only photovoltaic charge is used; mains supply is not utilized. This mode maximizes energy saving, with all battery energy coming from solar. Suitable for areas with good light conditions.
4.2 Output Modes
- Photovoltaic Priority Mode: Photovoltaic and battery supply power to the load. When selected, green solar energy is used as much as possible for energy conservation. Switches to mains supply if photovoltaics are invalid. Maximizes solar energy use while maintaining battery charge. Suitable for stable power grids.
- Mains Supply Priority Mode: Switches to inverter for power supply only when mains supply is invalid, acting as a backup UPS. Applicable for unstable power grids.
- Inverter Priority Mode: Switches to mains supply only in case of battery undervoltage. Maximizes DC electric energy use. Applied in areas with stable power grids.
- Mixed Functions Mode: When the battery is unavailable or fully charged, the load is powered by PV and commercial power, with maximum PV output.
5. Operation and Display Panel
The inverter features an LCD screen and LED indicators for displaying system data and operational status. Control is managed via touchable keys.
Figure 6: Front view of the PowMr Solar Inverter Charger with LCD display and control buttons.
5.1 Touchable Keys
| Function Key | Description |
|---|---|
| SET | Enter/exit setting menu |
| UP | Last option |
| DOWN | Next option |
| ENT | Confirm/enter option under setting menu |
5.2 LED Indicators
| Indicator Light | Color | Description |
|---|---|---|
| AC/INV | Yellow | Constant on: mains supply output Flashing: inverter output |
| CHARGE | Green | Flashing: battery in charge Constant on: charge completed |
| FAULT | Red | Constant on: fault state |
5.3 Real-time Data View Method
On the LCD main screen, press the "UP" and "DOWN" keys to navigate and view different real-time data of the machine. The screen displays input parameters (AC, PV, INV, WP), output parameters (output voltage, current, power), and various system statuses and settings.
5.4 Setting Parameters
To enter the setting menu, press the "SET" key. The parameter number [00] will flash. Use "UP" and "DOWN" to select the desired parameter. Press "ENT" to enter editing mode, adjust the value with "UP" and "DOWN", and press "ENT" again to confirm and return to parameter selection.
The manual provides detailed tables for various settings, including Work Priority Mode, Output Frequency, AC Input Voltage Range, Battery to Bypass Voltage, Charge Mode, Maximum Charge Current, Battery Type, Boost Charge Voltage, Float Voltage, Over Discharge Voltage, Equalizing Charge settings, Energy Saving Mode, Automatic Restart after Overload/Overtemperature, Buzzer Alarm, Mode Conversion Reminding, Inverter Overload to Bypass, AC Maximum Charge Current, Split Phase, RS485 Address Setting, and RS485-2 Communication.
Battery type parameters for Lead-acid and Lithium batteries are also detailed, including overvoltage disconnection, equalizing charge, boost charge, floating charge, undervoltage alarm, low voltage disconnection, discharge limit, over-discharge delay time, and charge/boost duration.
5.5 Communication Functions
5.5.1 Dry Node Function
This dry node can control the switch of a diesel generator to charge the battery. Under normal conditions, the NC-N point is closed and NO-N point is opened. When battery voltage reaches the low-voltage disconnection point, the relay coil energizes, closing NO-N and opening NC-N. This can drive resistive loads (125VAC/1A, 230VAC/1A, 30VDC/1A).
5.5.2 RS485 Communication Function
The inverter has two RS485 communication ports:
- RS485-2: Can be used for direct communication with lithium battery BMS (customization may be required).
- RS485-1: Connects to a selected RS485 to WiFi/GPRS communication module (developed by PowMr). With this module, the inverter can be connected via a mobile APP to check operating parameters and status.
5.5.3 USB Communication Function
This USB port is for communication with the selected upper computer software. To use this port, the corresponding "USB to serial port chip CH340T driver" must be installed on the computer.
Figure 7: Monitoring and control via the SmartESS App with optional Wi-Fi/GPRS module.
6. Troubleshooting
This section provides solutions for common issues encountered during the operation of the PowMr Hybrid Solar Inverter.
| Fault | Solving Measures |
|---|---|
| No display on screen | Check if battery air switch or PV air switch is closed and in "on" state. Press any key to exit screen sleep mode. |
| Charge battery overvoltage protection | Measure if battery voltage exceeds 60V. Disconnect PV array air switch and AC air switch. |
| Battery undervoltage protection | After battery charge restores above low-voltage disconnection recovery voltage. |
| Fan fault | Check if the fan is working or blocked. |
| Radiator overtemperature protection | When device cools below overtemperature recovery, it will restore to normal charge and discharge. |
| Bypass overload protection, inverting overload protection | ① Decrease consumer load. ② Restart all-in-one inverter; load output is restored. |
| Inverting short-circuit protection | ① Carefully check load connection, clear short-circuit fault. ② After power on again, load output is restored. |
| PV overvoltage | Check if PV input voltage exceeds maximum allowable input voltage with a multimeter. |
| No connection alarm of battery | Check if battery is disconnected or if the breaker at the battery side is not closed. |
7. System Maintenance
To maintain optimum and permanent operation performance, it is suggested to check the following items semiannually:
- Confirm that airflow around the inverter is not blocked. Remove any dirt or debris from the radiator.
- Check for damage to insulation of exposed wires (sun exposure, friction, dry rot, insect/rat damage). Repair or replace wires if necessary.
- Verify that indication and display are consistent with device operation. Address any fault or error displays.
- Check all terminals for corrosion, insulation damage, high temperature, or burning/discoloration. Tighten terminal screws.
- Check for dirt, nesting insects, and corrosion. Clean as required.
- If the arrester has failed, replace it promptly to protect the inverter and other devices against lightning damage.
WARNING: Danger of electric shock! To perform maintenance, ensure all power supplies to the inverter are disconnected and all capacitors are discharged. Then, inspection or operation can be performed.
PowMr is not responsible for damage caused by:
- Improper use or use in inappropriate places.
- Open-circuit voltage of photovoltaic module exceeding maximum allowable voltage.
- Operation ambient temperature beyond the limited operating temperature range.
- Unauthorized disassembly and maintenance.
- Force majeure: damage caused by transportation or handling of the inverter.
8. Specifications
8.1 General Specifications
| Parameter | Value |
|---|---|
| Model | POW-LVM5K-48V-N |
| Dimension (L*W*D) | 426mm*322mm*126mm |
| Weight (kg) | 11.5 |
| Operation Temperature Range | -10°C ~ 55°C |
| Storage Temperature Range | -25°C ~ 60°C |
| Humidity Range | 5% to 95% (three-proof paint protection) |
| Noise | ≤60dB |
| Thermal Dissipation | Forced cooling with adjustable air speed |
| Communication Interface | USB/RS485 (WiFi/GPRS)/Dry node control |
| Certification | CE(IEC62109)/CETL(UL 1741 C22.2 NO.107.1)/FCC/SAA |
| EMC Authentication Grade | EN61000 |
8.2 AC Mode Specifications
| Parameter | Value |
|---|---|
| Rated Input Voltage | 110/120Vac |
| Input Voltage Range | (90Vac-140Vac) |
| Frequency | 50Hz/60Hz (auto-sensing) |
| Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz) |
| Overload/Short-circuit Protection | Breaker |
| Efficiency | >95% |
| Conversion Time (Bypass and Inverting) | 10ms (Typical value) |
| AC Reverse Flowing Protection | Yes |
| Maximum Bypass Overload Current | 63A |
8.3 Inverting Mode Specifications
| Parameter | Value |
|---|---|
| Output Voltage Waveform | Pure sine wave |
| Rated Output Power (VA) | 5000 |
| Rated Output Power (W) | 5000 |
| Power Factor | 1 |
| Rated Output Voltage (Vac) | 120Vac |
| Output Voltage Error | ± 5% |
| Output Frequency Range (Hz) | 50Hz ± 0.3Hz, 60Hz ± 0.3Hz |
| Efficiency | >90% |
| Peak Power | 10000VA |
| Loaded Motor Capacity | 4HP |
| Output Short-circuit Protection | Breaker |
| Specification of Bypass Breaker | 63A |
| Overload Protection | (102% |
8.4 AC Charge Specifications
| Parameter | Value |
|---|---|
| Battery Type | Lead acid or lithium battery |
| Rated Battery Input Voltage | 48V (minimum start voltage 44V) |
| Battery Voltage Range | 40.0Vdc~60Vdc ± 0.6Vdc (settable LCD screen) |
| Maximum Charge Current | 40A |
| Charge Current Error | ± 5Adc |
| Charge Voltage Range | 48-58.4Vdc |
| Short-circuit Protection | Breaker and blown fuse |
| Breaker Specification | 63A |
| Overcharge Protection | Turn off charge after 1min alarm |
| Power Saving Mode | Load ≤50W |
8.5 Solar Charge Specifications
| Parameter | Value |
|---|---|
| Maximum PV Open-circuit Voltage | 500Vdc |
| PV Operation Voltage Range | 120-500Vdc |
| MPPT Voltage Range | 120-450Vdc |
| Battery Voltage Range | 40-60Vdc |
| Maximum Input Power | 5500W |
| Charge Current Range of Solar Energy (settable) | 0-80A |
| Charge Short-circuit Protection | Blown fuse |
| Wiring Protection | Inverse wiring protection |
9. Warranty and Support
For technical support or inquiries, please contact PowMr using the information below:
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
Please refer to the included Warranty Card for specific warranty terms and conditions.