1. Introduction
Thank you for choosing the Y&H MPPT Solar Charge Controller. This multi-functional LCD solar controller is designed to efficiently manage power from your solar panels to your battery bank, ensuring optimal charging and discharge control. It features a clock display and seven distinct operating modes to suit various solar power system needs. This manual provides detailed instructions for installation, operation, and maintenance to help you get the most out of your solar charge controller.

Figure 1: Y&H MPPT Solar Charge Controller
2. Package Contents
Please verify that all items listed below are included in your package upon opening:
- 1 x Y&H MPPT Solar Charge Controller (Host Machine)
- 1 x User Manual
- 1 x Pack of Desiccant
3. Specifications
| Feature | Specification |
|---|---|
| Model Number | SY-SLCD (SY60, SY80, SY100) |
| Maximum Current | 60A / 80A / 100A (depending on model) |
| Battery Voltage | 12V / 24V / 36V / 48V (Auto-sensing) |
| Input Voltage | DC12V/24V, DC36V, DC48V, DC96V |
| Output Voltage | DC12V/24V, DC36V, DC48V, DC5V/1.5A×2USB |
| Operating Temperature | -25°C ~ 55°C |
| Application | Charger Controller, Voltage Control, Solar Energy |
| Certification | CE |
| Length | 19 cm |
| Width | 18 cm |
| Height | 6 cm |
| Weight | 0.89 kg |
The controller boasts a high tracking efficiency of 98% and a conversion efficiency of 99%, ensuring maximum power harvest from your solar panels.

Figure 2: Compatible Battery Types (SLD GEL, Flooded, Lithium)
4. Setup Instructions
Proper connection is crucial for the safe and efficient operation of your solar charge controller. Please follow the connection and disconnection sequences carefully.
4.1. Connection Sequence (First Installation)
- Connect the **fully charged battery** to the controller.
- Connect the **solar panel** to the controller.
- Connect the **DC load** to the controller.
4.2. Disconnection Sequence
When disconnecting the system, follow the reverse order to prevent damage:
- Disconnect the **DC load** from the controller.
- Disconnect the **solar panel** from the controller.
- Disconnect the **battery** from the controller.

Figure 3: Wiring Diagram and Recommended PV Input Power
Note: The table in Figure 3 provides recommended photovoltaic input voltage and maximum PV input power for different battery voltages. For example, for a 12V battery, the recommended PV input voltage is 15V-23V with a maximum PV input power of 1200W.
5. Operating Instructions
The controller features a multi-functional LCD display and intuitive buttons for operation. It supports various charging and discharge control modes.
5.1. Display Screen Overview
The LCD screen provides real-time information about your solar system. It is divided into several areas:

Figure 4: At-a-Glance Display Interface
- Battery Work Status Display Area (1): Shows battery charging state and voltage. When charging, four bars dynamically display; in static state, it shows current battery level.
- Operating Status Area of Solar Panel (2): Indicates charging status (solar panel icon displayed) or stopping charge (icon not displayed). Displays charge current.
- Load Output Status and Display Areas of All Parameters (3): Shows load status (load icon light on when discharging, off when not). Displays controller's temperature (when 'C' is shown), battery electric quantity (when '%' is shown), 24-hour time (when 'Time' is shown), and timing start time (when 'Time ON' is shown).
- Mode Control Display Area (4): Shows the currently selected operating mode.
- Normal and Fault Status Display Area (5): Displays 'OK' for normal operation or 'Fault' for abnormalities.
5.2. Button Functions
- ▲ (Up Arrow / Reset): Used for numerical values and mode adjustment. Press and hold for 5 seconds to set high voltage disconnection protection.
- ■ (Menu): Used for setting/confirmation. Press and hold for 5 seconds to enter time setting status.
- ▼ (Down Arrow / On/Off): Used for displacement and impulse start/stop. Briefly press to adjust low voltage.
5.3. Operating Modes
The controller offers seven operating modes:
- Charging Mode: Always charges when conditions are met, never discharges.
- Light Control Mode: Discharges 10 minutes after detecting night, stops discharging 10 minutes after detecting daytime.
- Light and Time Delay Control Mode: Discharges 10 minutes after detecting night and counts down. Discharge stops when the timer reaches zero. Max delay: 23:59.
- Universal Control Mode: Always discharges under trouble-free conditions.
- Manual Control Mode: Uses the "▼" button to manually control discharge.
- Timing Control Mode: Opens or closes discharge regularly based on set times.
- Test Mode: Similar to Light and Time Delay Control Mode but without the 10-minute delay. (For factory testing only).

Figure 5: Load Working Modes
5.4. Setting Adjustments
Watch the video below for a visual guide on display operation and setting adjustments.
Video 1: Demonstration of Display Operation and Setting Adjustments
5.4.1. Time Setting
When charged, the controller enters time setting state. The first (leftmost) of the four values in the parameters display area will flicker. Press "▲" to adjust the value, and "▼" to move to the next digit. To re-enter time setting, long press "■" for 5 seconds.
5.4.2. Mode Adjustment
Press "■" to make the current control mode flicker. Use "▲" to select the desired control mode, then press "■" again to confirm.
5.4.3. Delay Stop Time Adjustment (Light Control + Delay Stop Control Mode)
After selecting and confirming "Light Control and delay" mode, the delay stop time parameters will automatically appear. Adjust these parameters similarly to time setting. The load output and parameter display area will show "Time OFF". After adjustment, press "■" to return to display mode. To re-adjust, press "■" twice.
5.4.4. Start and Stop Time Adjustment (Timing Control Mode)
When "Timing" control mode is selected and confirmed, the start time parameters will automatically appear. Adjust these parameters similarly to time setting. The load output and parameter display area will show "Time ON". After adjusting the start time and pressing "■", it will automatically switch to stop time parameters, showing "Time OFF". After finishing adjustment, press "■" to return to display mode.
6. Protection Parameters
The controller includes various protection mechanisms to safeguard your battery and system.
6.1. Voltage Protection
- 12V Battery: Low voltage protection at <10.5V (6s delay), recovers at 11.5V. Over voltage protection at >16.0V, recovers at 15.0V.
- 24V Battery: Low voltage protection at <21.0V (6s delay), recovers at 23.0V. Over voltage protection at >32.0V, recovers at 30.0V.
- 36V Battery: Low voltage protection at <31.5V (6s delay), recovers at 34.5V. Over voltage protection at >48.0V, recovers at 45.0V.
- 48V Battery: Low voltage protection at <42.0V (6s delay), recovers at 46.0V. Over voltage protection at >64.0V, recovers at 60.0V.
During voltage protection, the voltage value and "Fault" indicator will flicker, and discharge will stop.
6.2. Discharge Current Protection
- >150% Rated Current: Immediate protection, "Fault" flickers, discharge stops.
- 110%~150% Rated Current: 10-second delay for protection, "Fault" flickers, discharge stops.
- 100%~110% Rated Current: 10-second delay for protection, "Fault" flickers, discharge stops.
6.3. Charging Protection
- 12V Battery: Starts charging if voltage <13.0V, stops charging if voltage >14.8V.
- 24V Battery: Starts charging if voltage <26.0V, stops charging if voltage >29.6V.
- 36V Battery: Starts charging if voltage <39.0V, stops charging if voltage >44.8V.
- 48V Battery: Starts charging if voltage <52.0V, stops charging if voltage >59.2V.
7. Troubleshooting
The controller is designed to be robust, but should you encounter issues, the "Fault" indicator on the display will provide a warning. Here are some common issues and their indicators:
| Symptom / Indicator | Possible Cause | Solution |
|---|---|---|
| "Fault" flickers, voltage value flickers | Abnormal battery voltage (too high or too low) | Check battery connections and voltage levels. Ensure battery type is correctly configured if applicable. |
| "Fault" flickers, current value flickers | Discharge current is too large (overload) | Reduce the load connected to the controller. Check for short circuits in the load wiring. |
| "Fault" flickers, temperature value flickers | Controller temperature exceeds 75°C (overheating) | Ensure adequate ventilation around the controller. Relocate to a cooler environment if necessary. Reduce load. |
| No display on LCD screen | No power from battery or solar panel | Check battery and solar panel connections. Ensure battery has sufficient charge. |
Important Note: The controller can still discharge under low voltage protection. If you touch-hold the "▼" button for 5 seconds, discharge will continue to output. However, this can damage the battery and is not recommended for prolonged use.
8. Safety Warnings
⚠ WARNING:
- This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
- Do not set the product on fire to prevent permanent damage.
- Do not use this product in high temperature and wet environments.
- Do not dismantle this product to avoid damage or injury.
- Do not short circuit the output to prevent danger.
9. User Tips
- Always ensure your battery is fully charged before connecting the solar panel and load for the first time. This helps the controller correctly identify the battery voltage.
- Regularly check all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to power loss and potential hazards.
- Monitor the display for any 'Fault' indicators. Addressing issues promptly can prevent system damage and ensure longevity.
- For optimal performance, ensure the controller is installed in a well-ventilated area, away from direct sunlight or excessive heat sources, to prevent overheating.
10. Warranty and Support
For any technical assistance, warranty claims, or support inquiries, please contact the seller or manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.
A user manual in PDF format is available for download. You can access it via the following link: User Manual (PDF).