1. Introduction
This manual provides instructions for the safe and effective use of your LED Battery Indicator Voltage Meter Power Charge Indicator Module, model JX-3030N-1. This device is designed to monitor the voltage and charge status of various battery types, including acid and lithium batteries, making it a versatile tool for household maintenance, equipment assembly, and other electrical monitoring scenarios.
Intended Use: The module is suitable for monitoring battery voltage and charge levels in various applications. It is intended for use with designated materials and under normal working conditions only.
2. Safety Information
Please read and understand all safety instructions before operating the module. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure correct polarity when connecting the module to a battery. Incorrect wiring can damage the module and the battery.
- Do not expose the module to moisture, water, or extreme temperatures.
- Avoid physical impact or dropping the module.
- Keep the module out of reach of children.
- Do not attempt to open or modify the module. There are no user-serviceable parts inside.
3. Package Contents
- 1 x JX-3030N-1 LED Battery Indicator Module
4. Product Overview
The JX-3030N-1 module features a clear LED digital display for voltage readings and a graphical battery bar for charge status. It includes integrated mounting tabs for easy installation.
Figure 1: Front and rear view of the JX-3030N-1 module. The front displays voltage and battery level, while the rear shows the circuit board and connection points (CLK, DIO, +3.3V, GND).
Figure 2: Front view of the JX-3030N-1 module with pre-attached red and black power wires.
The module typically comes with red and black wires for connection. The rear of the PCB also shows pins labeled CLK, DIO, +3.3V, and GND, which may be for advanced integration or internal logic, but the primary connection for voltage monitoring is via the main power wires.
5. Setup and Installation
5.1 Wiring
- Ensure the power source (battery) is disconnected before making any connections.
- Connect the red wire from the module to the positive (+) terminal of the battery you wish to monitor.
- Connect the black wire from the module to the negative (-) terminal of the battery you wish to monitor.
- Double-check all connections for correct polarity to prevent damage.
Figure 3: Rear view showing typical wiring connections for the module's power input.
5.2 Mounting
The module features two mounting tabs with holes. Use appropriate screws (not included) to secure the module to a panel or enclosure. Ensure the mounting location is stable and provides adequate protection from environmental factors.
Figure 4: Module dimensions for mounting (approx. 40mm width, 30mm height).
5.3 Battery Type Configuration
The JX-3030N-1 module is designed to work with both acid and lithium batteries. Without explicit configuration instructions, it is assumed the module either auto-detects the battery type or is pre-configured for a common range. Users should verify the module's compatibility with their specific battery system.
6. Operation
- Once correctly wired and the battery is connected, the module will power on automatically and display the current voltage.
- The LED digital display shows the precise voltage in Volts (V).
- The surrounding green bar graph indicates the approximate charge level of the battery. A full bar indicates a fully charged battery, while a decreasing bar indicates a lower charge.
- The module may feature a power button icon on the display. If present, pressing this button might cycle through display modes or turn the display on/off.
7. Specifications
| Feature | Detail |
|---|---|
| Model | JX-3030N-1 |
| Display Type | LED Digital Display with Battery Bar |
| Monitored Battery Types | Acid/Lithium Battery (voltage range not explicitly specified, observed up to 24.3V) |
| DIY Supplies Category | Electrical |
| Origin | Mainland China |
| Certification | None |
| Battery Included | No |
| Data Record | No |
| High-concerned Chemical | None |
| Dimensions (Diameter) | Approx. 30mm (1.18 inches) |
| Dimensions (Width with tabs) | Approx. 40mm (1.57 inches) |
| Dimensions (Height) | Approx. 30mm (1.18 inches) |
| Package Weight | 0.2 kg |
| Package Dimensions | 5cm x 4cm x 2cm |
8. Maintenance
- Cleaning: Gently wipe the module's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: Store the module in a cool, dry place away from direct sunlight and corrosive chemicals when not in use.
9. Troubleshooting
- No Display:
- Check if the red and black wires are securely connected to the battery terminals.
- Verify that the battery has sufficient charge to power the module.
- Ensure correct polarity (+ to red, - to black).
- Incorrect Voltage Reading:
- Confirm the module is compatible with your battery's voltage range.
- Check for loose connections or corrosion at the battery terminals.
- Error Code Displayed (e.g., "Eh2"):
Figure 5: Example of an error code "Eh2" displayed on the module.
Specific error codes like "Eh2" indicate an issue. Without detailed documentation, common causes include out-of-range voltage, connection problems, or internal faults. Try disconnecting and reconnecting the module. If the issue persists, contact support.
10. User Tips
- For optimal accuracy, ensure clean and secure connections to the battery terminals.
- Consider using a fuse on the positive power line for added protection, especially in permanent installations.
- If monitoring different battery types, confirm the module's compatibility or any necessary configuration steps (if available).
11. Support and Warranty
For further technical documentation, including detailed guides and specifications, please refer to the official product PDF:
For warranty information or technical assistance, please contact the seller directly through your purchase platform.