1. Introduction
The DL24B-XSP16 is a versatile 4-wire test board designed for comprehensive testing of fast charging protocols, including PD3.1, PD3.0, QC, AFC, and FCP. It can induce various fast charging voltages (5V/9V/12V/15V/20V/28V) for charger aging, quality identification, and mini cable testing. This device is compatible with ATORCH DL24 series load testers and similar equipment.

2. Safety Information
- Always ensure proper connections before applying power.
- Do not exceed the maximum current rating of 5A.
- Handle the PCB with care to avoid damage to components.
- Keep the device away from liquids and extreme temperatures.
- Ensure adequate ventilation when performing long-term aging tests, especially with high power loads.
3. Setup
3.1 Power Supply
The DL24B-XSP16 test board requires an external DC12V power supply for operation. This power supply is not included and must be purchased separately.

3.2 Connections
The board features multiple input ports and a 4-wire output interface:
- Input Ports:
- DC5.5-IN1 (Male barrel jack)
- MINI USB-IN2 (Male)
- Micro USB-IN3 (Male)
- Type-C-IN4 (Female) - Supports PD3.1/3.0/QC/AFC/FCP protocols
- Output Interface:
- 4-wire terminals: I+, I-, V+, V- for connecting to constant current load devices (e.g., DL24 series).

To connect:
- Connect your charger, power bank, or DC power supply to one of the appropriate input ports on the DL24B-XSP16.
- Connect the 4-wire output terminals (I+, I-, V+, V-) to your compatible load tester (e.g., ATORCH DL24 series).
- Ensure all connections are secure before proceeding.
4. Operating Instructions
4.1 Button and Indicator Light Functions

- V- Key (DOWN):
- Single click: Sends voltage downshift protocol.
- Double-click or long press: Alternately sends 28V-20V-15V-12V-9V-5V fast charging voltage protocols.
- V+ Key (UP):
- Single click: Sends voltage upshift protocol.
- Double-click or long press: Alternately sends 5V-9V-12V-15V-20V-28V fast charging voltage protocols.
- Voltage Indicator Lights (LEDs): Displays the current triggered voltage level (5V, 9V, 12V, 15V, 20V, 28V).
- PD Protocol Communication Light: Indicates active PD communication.
- Power Indicator Light (PWR): Indicates the board is powered on.
4.2 Memory Functions
- Power Outage Memory Function: The device memorizes the last measurement mode used. Upon next power-on, it will automatically enter the same mode, reducing setup time for repetitive tests.
- Voltage Memory Function: The board stores the previously set protocol and voltage data. When powered on again, it will recall and apply these settings automatically. This is useful for consistent testing or using the board as a fixed voltage power source.

4.3 Testing Scenarios
4.3.1 DC Power Supply Detection and Aging
Connect a DC power adapter to the board's input and the board's output to a load tester. This setup allows for long-term aging tests of DC power supplies to evaluate their performance and stability.

4.3.2 Mini Cable Quality Inspection
Pair the DL24B-XSP16 with a compatible load tester (e.g., DL150B) to test the charging protocol and quality of data cables. This is useful for verifying cable authenticity and fast charging capabilities.

4.3.3 PD3.1/PD3.0 Protocol Testing
Connect a PD3.1 charger or power bank to the Type-C-IN4 port using a dedicated E-mark chip cable. If the PD3.1 handshake is successful, the PWR and voltage indicator lights will illuminate. Use the V+ and V- buttons to cycle through different voltage gears (5V/9V/12V/15V/20V/28V) and adjust the current on your load tester to determine the maximum power output of the charger.

4.3.4 QC/AFC/FCP Protocol Testing
Pair the test board with a QC charger and a fast charging cable. The corresponding voltage indicator light will illuminate when each protocol gear (e.g., 5V/9V for AFC, 5V/9V/12V for FCP) is successfully triggered. This allows you to test the maximum power and current capabilities of each gear.

5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the board. Avoid using liquids or abrasive cleaners.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Handling: Avoid dropping or subjecting the board to physical shock, as this can damage internal components.
6. Troubleshooting
- Device not powering on: Ensure the DC12V power supply is correctly connected and functional. Check all input connections.
- No voltage output/protocol trigger: Verify that the input charger/power bank is active and supports the desired fast charging protocol. Check cable integrity. Ensure the V+ and V- buttons are being pressed correctly.
- Inaccurate readings on load tester: Ensure the 4-wire output connections to the load tester are secure and correctly wired (I+, I-, V+, V-).
- Intermittent operation: Check for loose connections on all cables and terminals.
7. Specifications
| Parameter | Value |
|---|---|
| Model | DL24B-XSP16 |
| Material | PCB + Metal + IC |
| Nominal Current | 3A |
| Maximum Current | 5A |
| Interface | I+/I- Current Terminal, V+/V- Voltage Wiring |
| Dimensions (L x W x H) | 42mm x 40mm x 1.6mm |
| Supported Protocols | PD3.1, PD3.0, QC, AFC, FCP |
| PD3.1 Voltages | 5V, 9V, 12V, 15V, 20V, 28V |
| PD Voltages | 5V, 9V, 12V, 15V, 20V |
| QC Voltages | 5V, 9V, 12V, 20V |
| AFC Voltages | 5V, 9V |
| FCP Voltages | 5V, 9V, 12V |
| Max Power (PD3.1) | 140W (28V*5A, with E-marker cable) |

8. User Tips
No specific user tips were available from the provided data (reviews or Q&A). For optimal performance, always ensure you are using high-quality cables and a stable power source for your tests.
9. Warranty and Support
Warranty information for the DL24B-XSP16 is not available in this document. Please refer to your purchase documentation or contact the seller directly for details regarding warranty coverage and technical support.