1. Introduction

The DL24B-XSP16 is a versatile 4-wire test board designed for comprehensive testing of fast charging protocols, including PD3.1, PD3.0, QC, AFC, and FCP. It can induce various fast charging voltages (5V/9V/12V/15V/20V/28V) for charger aging, quality identification, and mini cable testing. This device is compatible with ATORCH DL24 series load testers and similar equipment.

Top-down view of the DL24B-XSP16 test board
Figure 1: Top-down view of the DL24B-XSP16 test board, showing various input ports and 4-wire output terminals.

2. Safety Information

  • Always ensure proper connections before applying power.
  • Do not exceed the maximum current rating of 5A.
  • Handle the PCB with care to avoid damage to components.
  • Keep the device away from liquids and extreme temperatures.
  • Ensure adequate ventilation when performing long-term aging tests, especially with high power loads.

3. Setup

3.1 Power Supply

The DL24B-XSP16 test board requires an external DC12V power supply for operation. This power supply is not included and must be purchased separately.

DL24B-XSP16 connected to a load tester, highlighting the DC12V power requirement
Figure 2: The DL24B-XSP16 requires a DC12V power supply (not included) for operation when used with a load tester.

3.2 Connections

The board features multiple input ports and a 4-wire output interface:

  • Input Ports:
    • DC5.5-IN1 (Male barrel jack)
    • MINI USB-IN2 (Male)
    • Micro USB-IN3 (Male)
    • Type-C-IN4 (Female) - Supports PD3.1/3.0/QC/AFC/FCP protocols
  • Output Interface:
    • 4-wire terminals: I+, I-, V+, V- for connecting to constant current load devices (e.g., DL24 series).
DL24B-XSP16 Operation Method diagram showing all input and output connections
Figure 3: DL24B-XSP16 connection diagram. Connect input from charger/power bank and output to a load device.

To connect:

  1. Connect your charger, power bank, or DC power supply to one of the appropriate input ports on the DL24B-XSP16.
  2. Connect the 4-wire output terminals (I+, I-, V+, V-) to your compatible load tester (e.g., ATORCH DL24 series).
  3. Ensure all connections are secure before proceeding.

4. Operating Instructions

4.1 Button and Indicator Light Functions

Diagram of DL24B-XSP16 buttons and indicator lights
Figure 4: Button and indicator light functions.
  • V- Key (DOWN):
    • Single click: Sends voltage downshift protocol.
    • Double-click or long press: Alternately sends 28V-20V-15V-12V-9V-5V fast charging voltage protocols.
  • V+ Key (UP):
    • Single click: Sends voltage upshift protocol.
    • Double-click or long press: Alternately sends 5V-9V-12V-15V-20V-28V fast charging voltage protocols.
  • Voltage Indicator Lights (LEDs): Displays the current triggered voltage level (5V, 9V, 12V, 15V, 20V, 28V).
  • PD Protocol Communication Light: Indicates active PD communication.
  • Power Indicator Light (PWR): Indicates the board is powered on.

4.2 Memory Functions

  • Power Outage Memory Function: The device memorizes the last measurement mode used. Upon next power-on, it will automatically enter the same mode, reducing setup time for repetitive tests.
  • Voltage Memory Function: The board stores the previously set protocol and voltage data. When powered on again, it will recall and apply these settings automatically. This is useful for consistent testing or using the board as a fixed voltage power source.
Diagram illustrating voltage memory function
Figure 5: Voltage memory function. The board recalls the last set voltage upon power-on.

4.3 Testing Scenarios

4.3.1 DC Power Supply Detection and Aging

Connect a DC power adapter to the board's input and the board's output to a load tester. This setup allows for long-term aging tests of DC power supplies to evaluate their performance and stability.

DC power supply detection and aging setup
Figure 6: Setup for DC power supply detection and long-term aging tests.

4.3.2 Mini Cable Quality Inspection

Pair the DL24B-XSP16 with a compatible load tester (e.g., DL150B) to test the charging protocol and quality of data cables. This is useful for verifying cable authenticity and fast charging capabilities.

Mini cable quality inspection setup
Figure 7: Setup for mini cable quality inspection using a load tester.

4.3.3 PD3.1/PD3.0 Protocol Testing

Connect a PD3.1 charger or power bank to the Type-C-IN4 port using a dedicated E-mark chip cable. If the PD3.1 handshake is successful, the PWR and voltage indicator lights will illuminate. Use the V+ and V- buttons to cycle through different voltage gears (5V/9V/12V/15V/20V/28V) and adjust the current on your load tester to determine the maximum power output of the charger.

PD3.1/PD3.0 protocol testing setup with a 140W charger
Figure 8: Testing PD3.1/PD3.0 protocols with a 140W charger and load tester.

4.3.4 QC/AFC/FCP Protocol Testing

Pair the test board with a QC charger and a fast charging cable. The corresponding voltage indicator light will illuminate when each protocol gear (e.g., 5V/9V for AFC, 5V/9V/12V for FCP) is successfully triggered. This allows you to test the maximum power and current capabilities of each gear.

QC fast charging protocol testing setup
Figure 9: Testing QC, AFC, and FCP fast charging protocols.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the board. Avoid using liquids or abrasive cleaners.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Avoid dropping or subjecting the board to physical shock, as this can damage internal components.

6. Troubleshooting

  • Device not powering on: Ensure the DC12V power supply is correctly connected and functional. Check all input connections.
  • No voltage output/protocol trigger: Verify that the input charger/power bank is active and supports the desired fast charging protocol. Check cable integrity. Ensure the V+ and V- buttons are being pressed correctly.
  • Inaccurate readings on load tester: Ensure the 4-wire output connections to the load tester are secure and correctly wired (I+, I-, V+, V-).
  • Intermittent operation: Check for loose connections on all cables and terminals.

7. Specifications

ParameterValue
ModelDL24B-XSP16
MaterialPCB + Metal + IC
Nominal Current3A
Maximum Current5A
InterfaceI+/I- Current Terminal, V+/V- Voltage Wiring
Dimensions (L x W x H)42mm x 40mm x 1.6mm
Supported ProtocolsPD3.1, PD3.0, QC, AFC, FCP
PD3.1 Voltages5V, 9V, 12V, 15V, 20V, 28V
PD Voltages5V, 9V, 12V, 15V, 20V
QC Voltages5V, 9V, 12V, 20V
AFC Voltages5V, 9V
FCP Voltages5V, 9V, 12V
Max Power (PD3.1)140W (28V*5A, with E-marker cable)
Product size diagram of DL24B-XSP16
Figure 10: Product dimensions and terminal details.

8. User Tips

No specific user tips were available from the provided data (reviews or Q&A). For optimal performance, always ensure you are using high-quality cables and a stable power source for your tests.

9. Warranty and Support

Warranty information for the DL24B-XSP16 is not available in this document. Please refer to your purchase documentation or contact the seller directly for details regarding warranty coverage and technical support.

© 2023 ATORCH. All rights reserved.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.