1. Important Safety Instructions
Please save these instructions for future use!
This manual contains all safety, installation and operating instructions for the POW-LVM5K Series all-in-one solar charge inverter.
Please read all instructions and precautions in the manual carefully before installation and use.
- Non-safety voltage exists inside the all-in-one solar charge inverter. To avoid personal injury, users shall not disassemble the all-in-one solar charge inverter themselves. Contact our professional maintenance personnel if there is a need for repair.
- Do not place the all-in-one solar charge inverter within the reach of children.
- Do not install the all-in-one solar charge inverter in harsh environments such as moist, oily, flammable or explosive, or heavily dusty areas.
- The mains input and AC output are high voltage, so please do not touch the wiring terminals.
- The housing of the all-in-one solar charge inverter is hot when it is working. Do not touch it.
- Do not open the terminal protective cover when the all-in-one solar charge inverter is working.
- It is recommended to attach proper fuse or circuit breaker to the outside of the all-in-one solar charge inverter.
- Always disconnect the fuse or circuit breaker near the terminals of PV array, mains and battery before installing and adjusting the wiring of the all-in-one solar charge inverter.
- After installation, check that all wire connections are tight to avoid heat accumulation due to poor connection, which is dangerous.
- The all-in-one solar charge inverter is off-grid. It is necessary to confirm that it is the only input device for load, and it is forbidden to use it in parallel with other input AC power to avoid damage.
2. Product Overview
The PowMr POW-LVM5K series is a new type of mixed solar energy storage inverting & control all-in-one inverter integrating solar energy storage & municipal power charge storage and AC sine wave output. It adopts DSP control and advanced control algorithm to achieve characteristics of high response speed, high reliability and high industrial standard.
It features four charge modes (only solar power, mains power priority, solar power priority, mains power & solar power) and two optional output modes (inverting and mains power) to meet different application needs.
The solar charge module utilizes optimized MPPT tracking technology for maximum power point tracking of the photovoltaic array in real-time, ensuring wide voltage range MPPT.
The AC-DC charge module employs an advanced control algorithm for full digital double closed-loop control of voltage and current, providing stable and reliable battery charging with wide AC voltage input range and comprehensive protection.
The DC-AC inverter module, based on full digital intelligent design, uses advanced SPWM technology to output pure sine wave, suitable for various AC loads including household appliances, electric tools, and electronic audiovisual equipment. The segment LCD display shows real-time operation data and system status, with comprehensive electronic protection functions ensuring safety and stability.
Key Features:
- Full digital voltage and current double closed-loop control with advanced SPWM technology for pure sine wave output.
- Two output modes: mains bypass and inverter output for uninterrupted power supply.
- Four optional charge modes: only solar energy, mains priority, solar energy priority, and mixed charge.
- Advanced MPPT technology with efficiency up to 99.9%.
- Wide MPPT voltage range.
- Activates lithium batteries with solar energy and AC mains power; supports lead-acid and lithium batteries.
- LCD screen and 3 LED indicator lights dynamically display system data and operation states.
- ON/OFF rocker switch controls AC output.
- Power saving mode reduces no-load loss.
- Intelligent adjustable speed fan for efficient heat dissipation and extended system life.
- Multiple protection functions and 360° comprehensive protection.
- Complete short circuit protection, overvoltage and undervoltage protection, overload protection, back filling protection, etc.
- Mixed load function: allows photovoltaic and commercial power to supply load simultaneously when battery is not connected or fully charged, maximizing photovoltaic energy use.



3. Basic System Introduction
A complete system includes the following parts:
- Photovoltaic module: Converts light energy into direct current energy, then charges the battery via the all-in-one inverter, or directly inverts light energy into alternating current to supply power to the load.
- Mains or generator: Connected at the AC input, it supplies power to the load and charges the battery simultaneously. If no mains power or generator is connected, the system can still operate normally, with load power supplied by the battery and photovoltaic modules.
- Battery: Ensures normal power consumption of the system load when solar energy or mains supply is insufficient.
- Household load: Can be connected to various household and office AC loads such as refrigerators, lamps, televisions, fans, and air conditioners.
- Inverting and control all-in-one inverter: The energy conversion device of the whole system.
The specific system wiring mode is determined by the actual application scenario.

4. Product Overview and Components
The diagram below illustrates the various ports and controls of the PowMr Hybrid Solar Inverter.

| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Overload protector | 9 | Dry contact port |
| 2 | ON/OFF rocker switch | 10 | Cooling fan |
| 3 | AC input port | 11 | Battery port |
| 4 | AC output port | 12 | Cooling fan |
| 5 | Grounding screw hold | 13 | PV port |
| 6 | RS485-2 communication port | 14 | Touch the key lightly |
| 7 | USB communication port | 15 | Indicator light |
| 8 | RS485-1 communication port | 16 | LCD screen |
5. Installation
5.1. Installation Notice
- Take care while installing the battery. When installing the lead-acid liquid battery, it is required to wear goggles. Any body part contacting the battery acid must be washed with clear water in time.
- Don't place any metal object beside the battery to prevent short circuit of the battery.
- Acid gas may be generated during battery charge. Therefore, it is required to ensure good ventilation around the environment.
- During cabinet installation, sufficient space shall be reserved around the all-in-one inverter for heat dissipation; do not install the all-in-one inverter and lead-acid liquid battery in the same cabinet to avoid the corrosion of the all-in-one inverter by acid gas generated during battery operation.
- Only the battery with type consistent with the all-in-one inverter can be charged.
- Loose connection points and corroded wires may cause great heat, thereby melting the insulation layer of wires, burning the surrounding materials, or even causing fire. Therefore, all connectors must be tightened, and the wires must be fixed with ties, so as to avoid the looseness of connectors caused by wire shaking during mobile application.
- Tie conductors are selected based on no greater than 5A/mm² current density.
- The machine installed outdoors shall be protected against direct sunlight and rain.
- After the power switch is turned off, there is still high voltage inside the all-in-one inverter. Please do not open or touch the internal components, and carry out relevant operation after the capacitor is fully discharged.
- Please do not install the all-in-one inverter in a humid, greasy, flammable, explosive or dusty or other severe environments.
- The polarity of the battery input end of this product shall not be reversed, otherwise the device may be damaged easily or there may be some unpredictable dangers.
- AC supply input and AC output are both high voltage, so please do not touch the wires.
- Do not touch the fan in working to prevent injury.
- It is required to confirm that the all-in-one inverter is the unique power supply input device for the load device. It is forbidden to use the machine in parallel with other input AC power to avoid damage.
5.2. Select the Mount Location
Confirm the installation position and heat dissipation space, such as a wall surface. To ensure sufficient air flow through the cooling fins, reserve at least 200mm space at the left and right air outlets for natural convection.

WARNING: Danger of explosion! Never install the all-in-one inverter and lead-acid liquid battery into the same sealed space or in a sealed place with probable accumulation of battery gas.
5.3. Mount the Inverter
Install the unit by screwing two screws. It's recommended to use M6 screws.
5.4. Preparation for Wiring
Before connecting all wirings, please take off the bottom cover by removing two screws.

5.5. Connection
For wiring and installation, observe national and local electrical specification requirements.
5.5.1. Wiring Specification and Breaker Type
The output current of the photovoltaic array affects the minimum wire diameter. Refer to the short circuit current value in the specification of the photovoltaic array. The short circuit current of series-connected arrays remains unchanged, while for parallel-connected arrays, it is the sum of individual component currents. The array's short circuit current must not exceed the maximum PV input current.
| Model | Wire Diameter | Max. PV input current | Circuit breaker Spec |
|---|---|---|---|
| POW-LVM5K-48V-N | 6mm²/10AWG | 22A | 2P-25A |
Note: The voltage in series shall not exceed maximum PV input open-circuit voltage.
| Model | Wire Diameter | Max. bypass input current | Circuit breaker Spec |
|---|---|---|---|
| POW-LVM5K-48V-N | 10mm²/7AWG | 63A | 2P-63A |
Note: A corresponding breaker is already present at the mains input connection point, so no additional one is needed.
| Model | Wire Diameter | Rated Battery Discharge Current | Max. Charge Current | Circuit Breaker Spec |
|---|---|---|---|---|
| POW-LVM5K-48V-N | 30mm²/7AWG | 125A | 80A | 2P-200A |
| Model | Wire diameter | Rated Inverter AC Output current | Max. bypass output current | Circuit Breaker Spec |
|---|---|---|---|---|
| POW-LVM5K-48V-N | 10mm²/7AWG | 42A | 63A | 2P-63A |
Note: Wire diameter is for reference only. For long distances between the photovoltaic array and inverter, or between the inverter and battery, use thicker wire to reduce voltage drop and improve system performance.
5.5.2. AC Input/Output Wiring
- Before AC input/output wiring, disconnect the external breaker and confirm the cable thickness. Refer to the