1. Introduction
This manual provides comprehensive instructions for the ECGSOLAX 3.6KW Hybrid Solar Inverter, model ECG-HVM3.6K-24V. This multifunctional solar inverter integrates an MPPT solar charge controller, a high-frequency pure sine wave inverter, and a UPS function module into a single unit. It is designed for off-grid backup power and self-consumption applications.
This datasheet is valid for the 3600W inverter.
2. Key Features
- Pure sine wave AC output
- Rated power 3.6kVA/kW, power factor 1
- Programmable supply priority for PV, battery, or Grid
- High PV input voltage range (55~450VDC)
- Built-in Max 100A (3.6KW) MPPT solar charge controller
- MPPT range 40V~450V, 500Voc
- Compatible with lithium-ion batteries
- Supports BMS communication via CAN/RS485 with Lithium batteries
- Smart battery charge design to optimize battery life
- Overload, high temperature, and inverter output short circuit protection
- Cold start function
- Intelligent fan speed adjustment
- Built-in anti-dust kit for harsh environments (optional)
- WIFI remote monitoring (optional) and GPRS available for iOS and Android
- Ability to work without a battery
- Feed-in to grid capability
- High frequency with small size and light weight
- Can power loads from solar and grid simultaneously
3. Safety Information
Please read all instructions and cautionary markings on the unit and in this manual before installation and operation. Failure to follow these instructions may result in electric shock, fire, or severe injury.
3.1 General Safety Precautions
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly sized and installed according to local electrical codes.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials, moisture, and direct sunlight.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (PV, battery, AC input) before performing any maintenance or wiring.
3.2 Battery Safety
- Use only compatible battery types as specified in this manual.
- Wear appropriate personal protective equipment (PPE) when working with batteries.
- Ensure proper battery ventilation to prevent accumulation of explosive gases.
- Do not short-circuit battery terminals.
4. Product Overview
The ECGSOLAX Hybrid Solar Inverter features a user-friendly interface and robust connection points.
4.1 Front Panel Indicators and Buttons
Image: Front view of the ECGSOLAX 3.6KW Hybrid Solar Inverter, highlighting its 3600W power, 24V battery voltage auto-detection, 500VDC maximum PV input, and 100A MPPT maximum charging current.
- AC Indicator
- Invert Indicator
- Charging Indicator
- Fault Indicator
- LCD Display
- ESC Button
- Up Button
- Down Button
- Enter Button
4.2 Rear Panel Connections
Image: Connection Diagram showing solar modules, generator/utility, external battery packs, and home appliances connected to the inverter.
- Power On/Off Switch
- AC Input
- AC Output 1
- PV Input
- Battery Input
- BMS Port (CAN/RS485)
- COM Port (RS232)
- PE (Protective Earth) Terminal
5. Packing List
Verify that all items are included in the package:
| No. | Item | Quantity | Description | Remarks |
|---|---|---|---|---|
| 1 | Inverter | 1 | ||
| 2 | Datasheet | 1 | English | |
| 3 | User manual | 1 | English | |
| 4 | Tubular Terminal | 8 | E2510 | For AC output, AC input, PV |
| 5 | OT Terminal | 1 | For PE |
6. Setup and Installation
6.1 Installation Environment
- Mount the inverter in a well-ventilated area, free from direct sunlight, dust, and moisture.
- Ensure sufficient clearance around the unit for proper airflow.
- Avoid installing near flammable or explosive materials.
- The operating temperature range is -10°C to 60°C.
6.2 Wiring Connections
Refer to the connection diagram for proper wiring. All connections must be secure and correctly polarized.
Image: Detailed Connection Diagram for ECGSOLAX Hybrid Solar Inverter, illustrating connections for solar modules, generator/utility, external battery packs, and home appliances.
- PV Input: Connect solar modules to the PV input terminals. Ensure the PV input voltage and current are within the specified limits (Max PV Open Circuit Voltage 500VDC, MPPT Range 40-450VDC).
- AC Input: Connect the utility grid or a generator to the AC input terminals.
- Battery Input: Connect the external battery pack to the battery input terminals. Ensure correct polarity. The inverter is compatible with various battery types including Sealed, GEL, Flooded, AGM, and Lithium.
- AC Output: Connect your home appliances or loads to the AC output terminals.
- BMS/COM Ports: For advanced communication with Lithium batteries (BMS) or monitoring systems (COM), connect appropriate cables.
- PE Terminal: Connect the protective earth ground.
6.3 Battery Compatibility
Image: The inverter is compatible with multiple battery types, including Sealed, GEL, Flooded, AGM, Lithium, and User Custom Battery.
The inverter supports various 24V battery types, including:
- Sealed Lead-Acid
- GEL Lead-Acid
- Flooded Lead-Acid
- AGM Lead-Acid
- Lithium-ion (with BMS communication)
- User Custom Battery settings
7. Operation Modes
The ECGSOLAX Hybrid Solar Inverter offers flexible charging and output modes to suit various energy management needs.
7.1 Charging Modes
Image: Diagram illustrating the four charging models: Solar Charging, Electricity Utility Priority, Solar Priority, and Hybrid Charging. Also shows Overtemperature and Overload Protection.
- Solar Charging: Prioritizes solar power for charging batteries.
- Utility Priority: Uses utility power to charge batteries when solar is insufficient.
- Solar Priority: Prioritizes solar power for both charging and powering loads.
- Hybrid Charging: Combines solar and utility power for charging.
7.2 Output Modes
Image: Diagram illustrating the four charging models and three load working models: Utility First, Solar First, and SBU First.
- Utility First: Prioritizes utility power to supply loads.
- Solar First: Prioritizes solar power to supply loads.
- SBU First (Solar-Battery-Utility): Prioritizes solar, then battery, then utility to supply loads.
7.3 Applications
Image: Various applications of the 3600W Solar Inverter Charger, including Solar Station System, Solar Home System, Hybrid Energy System, Solar RVs/Vessels System, and backup power.
The inverter is suitable for a wide range of applications, including:
- Solar Station Systems
- Solar Home Systems
- Hybrid Energy Systems
- Solar RVs/Vessels Systems
- General backup power solutions
Image: Multi-function diagram illustrating various home appliances (air conditioner, refrigerator, fan, microwave oven, washing machine, vacuum cleaner, television) that can be powered by the inverter.
8. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Periodically clean the exterior of the inverter and ventilation openings to prevent dust accumulation. Use a dry cloth; do not use liquids.
- Connection Check: Annually inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
- Battery Inspection: Check battery terminals for corrosion and ensure battery fluid levels (for flooded batteries) are adequate. Monitor battery health and replace as needed.
- Environment: Ensure the installation environment remains within specified temperature and humidity ranges.
9. Troubleshooting
This section provides guidance for common issues. For complex problems, contact qualified service personnel.
| Problem | Possible Cause | Solution |
|---|---|---|
| No power/LCD display off | Inverter is off; battery disconnected; no PV/AC input. | Turn on the inverter; check battery connections; verify PV and AC input sources. |
| No AC output | Overload; short circuit; inverter fault; battery low. | Reduce load; check for short circuits; check fault indicator; charge battery. |
| Fault Indicator (4) is lit | Internal fault, overtemperature, overload, etc. | Refer to the LCD display for specific error codes. Disconnect loads, restart the inverter. If persistent, contact support. |
| Battery not charging | PV input too low; AC input not present; charging mode incorrect; battery fault. | Check PV array; verify AC input; select appropriate charging mode; inspect battery. |
10. Specifications
10.1 Electrical Specifications
| AC Input | |
|---|---|
| Rated Input Voltage (VAC) | 208/220/230/240; L+N+PE |
| Voltage Range (VAC) | 90~280 (APP/GEN mode); 170~264 (UPS mode) |
| Frequency (Hz) | 50/60 (Auto Adaptive) |
| AC Output | |
|---|---|
| Rated Capacity (kVA/kW) | 3.6 (Output Power rating will be reduced to 90%, when setting the Output Voltage to 208V) |
| Surge Power (kVA) | 7.2 |
| Voltage (VAC) | 208/220/230/240 |
| Power Factor (PF) | 1 |
| Frequency (Hz) | 50/60±0.1% |
| Switch Time (ms) | 10 (APP/UPS mode) / 20 (GEN mode) |
| WaveForm | Pure SineWave |
| Overload Capacity (Battery Mode) | 60s@102%~110%load; 10s@110%~130%load; 3s@130%~150%load; 0.2s@150%-200%load |
| Max. Efficiency (Battery Mode) | 92%@24VDC |
| Charger (PV/AC) | |
|---|---|
| Solar Charger Type | MPPT |
| Max PV Input Current (A)/Power (W) | 18/5000 |
| MPPT Range@Operating Voltage (VDC) | 40-450 |
| PV Start-up Voltage (VDC) | 60 |
| Max PV Open Circuit Voltage (VDC) | 500 |
| Max PV Charge Current (A) | 100 |
| Max AC Charge Current (A) | 100 |
| Max. Charge Current (PV+AC) (A) | 100 |
| Battery | |
|---|---|
| Normal Voltage (VDC) | 24 |
| Battery Type | Lithium/Lead-acid |
10.2 General Data
| General Data | |
|---|---|
| HMI | LCD |
| Interface | RS485/CAN/RS232 |
| Monitoring | WiFi (Optional) |
| Ingress Protection | IP21 |
| Operating Temperature (°C) | -10~60 |
| Relative Humidity | 5%~95% (Non-condensing) |
| Storage Temperature (°C) | -15~60 |
| Max. Operating Altitude (m) | 4000 (Derating above 2000) |
10.3 Physical Specifications
- Weight: 7.5 kg
- Dimensions (L x W x H): 46 cm x 36 cm x 17 cm
10.4 Output Power Derating Conditions
The output power rating will be reduced due to various conditions. The 'L' in the diagram represents being accessed or connected, while 'N' signifies not being accessed or not connected.
| Battery | PV | AC Input | Max Output Power |
|---|---|---|---|
| L | N | N | Follow the Battery Voltage Derating Curve as shown below. |
| N | L | N | Depends on the PV input power and Maximum is 3.6kW. |
| N | N | L | Input Voltage * Input Max current 20A |
Two ways to achieve 3.6kW are as follows:
|
|||
| L | L | N | Input Voltage * Input Max Current 20A |
| L | N | L | Input Voltage * Input Max Current 20A |
| L | L | L | Input Voltage * Input Max Current 20A |
Battery Voltage Derating Curve:
Image: Graph showing Output Load (3000W to 3600W) versus Battery Voltage (21V, 24V, 26V), illustrating the Battery Voltage Derating Curve.
11. User Tips
- The inverter is reported to work well and is almost plug-and-play for 240V systems.
- It accepts petrol generator input, providing flexibility for AC power sources.
12. Frequently Asked Questions (FAQ)
- Q: Does the inverter work without a battery?
- A: Yes, this inverter has the ability to work without a battery, utilizing solar and/or grid power directly for loads.
- Q: Can it work without a solar panel?
- A: Yes, while designed for solar, the inverter can operate without solar panels if there is a battery connected or an AC input (utility/generator) available to power loads and/or charge the battery.
13. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official ECGSOLAX website or contact your authorized dealer. A user manual in PDF format is also available for download: ECGSOLAX Hybrid Solar Inverter User Manual (PDF).