1. Introduction
This manual provides essential information for the safe and efficient operation of your Daxtromn JGH-6.2KW Off-Grid Solar Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference. This inverter is designed to convert DC power from solar panels and batteries into AC power for household appliances, featuring a built-in MPPT solar charger and pure sine wave output.

Figure 1: Daxtromn JGH-6.2KW Solar Inverter with key specifications.
2. Product Overview
Familiarize yourself with the components and interfaces of your inverter.

Figure 2: Product Overview and Component Identification.
Front Panel Components:
- LCD Display: Shows operating status, load, input, and output information.
- Status Indicator: LED to indicate operational status.
- Charging Indicator: LED to indicate battery charging status.
- Fault Indicator: LED to indicate system faults.
- ESC Button: Escape/back button for menu navigation.
- Up Button: Navigates up in menus or increases values.
- Down Button: Navigates down in menus or decreases values.
- Enter Button: Confirms selections or enters sub-menus.
Side and Rear Panel Connections:
- RS232 Communication Port: For PC communication.
- BMS/RS485 Communication Port: For Battery Management System (BMS) or RS485 communication.
- CT Signal Port: Current Transformer signal port.
- Power ON/OFF Switch: Main power switch for the inverter.
- Output Ground Wire: Connection point for system grounding.
- AC Input: Terminal for connecting AC utility or generator power.
- AC Output: Terminal for connecting AC loads (home appliances).
- PV Input: Terminals for connecting solar panel arrays.
- Battery Terminal Positive (+): Positive connection for battery bank.
- Battery Terminal Negative (-): Negative connection for battery bank.
3. Setup and Installation
Proper installation is crucial for safety and performance. Ensure all connections are secure and follow local electrical codes.
3.1 Safety Precautions
- Ensure the inverter is turned OFF before making any connections.
- Only qualified personnel should perform electrical installations.
- Wear appropriate personal protective equipment (PPE).
- Do not disconnect batteries while the unit is in operation.
- Ensure proper grounding of the inverter.
3.2 Mounting the Inverter
Mount the inverter in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure there is sufficient clearance around the unit for airflow. The unit should be mounted vertically on a sturdy surface.
3.3 Connection Diagram
The following diagram illustrates the typical connection setup for the JGH-6.2KW inverter.

Figure 3: Typical Connection Diagram.
3.4 Wiring Instructions
- Battery Connection: Connect the external battery packs to the Battery Terminal Positive (+) and Negative (-) terminals on the inverter. Ensure correct polarity. The inverter supports 48V battery systems.
- PV Input Connection: Connect your solar panel array to the PV Input terminals. Ensure the total PV voltage and current are within the inverter's specifications (Max PV Input Voltage 500Vdc, MPPT Input Voltage Range 60-500Vdc).
- AC Input Connection (Optional): If using a generator or utility grid as a backup/charging source, connect it to the AC Input terminals.
- AC Output Connection: Connect your home appliances or load center to the AC Output terminals.
- Grounding: Connect a ground wire from the Output Ground Wire terminal to a reliable earth ground.
4. Operating the Inverter
4.1 Powering On/Off
- To Power On: After all connections are secure, switch the Power ON/OFF Switch (12) to the 'ON' position. The LCD display will light up, and the inverter will begin its startup sequence.
- To Power Off: Disconnect all AC loads, then switch the Power ON/OFF Switch (12) to the 'OFF' position.
4.2 LCD Display and Settings
The LCD display (1) provides real-time information about the inverter's operation. Use the ESC (5), Up (6), Down (7), and Enter (8) buttons to navigate through menus and adjust settings. Refer to the detailed PDF user manual for specific menu structures and parameter adjustments, including:
- Output voltage and frequency settings.
- Charging source priority (Solar, Utility, Solar+Utility).
- Battery type and charging parameters.
- Load source priority.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris. Use a dry cloth to clean the exterior. Do not use liquid cleaners.
- Connections: Periodically check all electrical connections for tightness and signs of corrosion.
- Environment: Ensure the operating environment remains within specified temperature and humidity ranges.
- Battery Health: Monitor your battery bank's health according to the battery manufacturer's guidelines.
6. Troubleshooting
If the inverter is not functioning correctly, check the following before contacting support:
| Problem | Possible Cause | Solution |
|---|---|---|
| No output power | Inverter OFF, battery low, overload, fault | Check ON/OFF switch, check battery voltage, reduce load, check fault indicator. |
| Battery not charging | PV input low/disconnected, AC input disconnected, charger settings incorrect | Check PV connections and sunlight, check AC input, verify charger settings on LCD. |
| Fault indicator on | Overload, short circuit, over-temperature, battery fault | Refer to LCD display for specific fault code, clear fault condition (e.g., reduce load, allow cooling), restart inverter. |
7. Specifications
Detailed technical specifications for the Daxtromn JGH-6.2KW inverter.

Figure 4: Product Data Sheet.
Product Data Sheet - Model JGH-6.2KW
| Category | Parameter | Value |
|---|---|---|
| AC Input Voltage | Rated AC Input | 220VAC (Standard) / 110VAC (Optional) |
| Input Voltage Range | 90-280VAC±3V (Normal); 170-280VAC±3V (UPS) | |
| Input Frequency | 50/60Hz±5% | |
| Rated Power | 6200W | |
| Output | Rated Output Power | 6200W |
| Output Voltage | 220/230/240VAC±5% | |
| Output Frequency | 50/60Hz±0.1% | |
| Output Waveform | Pure Sine Wave | |
| Transfer Time | ≤10ms (UPS Mode); ≤20ms (INV Mode) | |
| Peak Power | 12400VA | |
| Overload Ability | 115%@105%-150% Load; 2s@150%~200% Load | |
| Grid-Connected Operation | Output Voltage | 220/230/240VAC |
| Grid Voltage Range | 170-265VAC | |
| Grid Frequency Range | 49-51±1Hz / 59-61±1Hz | |
| Rated Output Current | 26.9A | |
| Power Factor Range | >0.99 | |
| Peak Efficiency (DC/AC) | 98% | |
| Battery | Rated Voltage | 48Vdc |
| Max Charging Voltage | 60V | |
| Constant Charging Voltage | 56.4Vdc | |
| Float Charging Voltage | 54Vdc | |
| Charger | PV Charging Mode | MPPT |
| Max PV Input Power | 8500W | |
| MPPT Input Voltage Range | 60-500Vdc | |
| Optimal Vmp Range | 300-400Vdc | |
| Max PV Input Voltage | 500Vdc | |
| Max PV Input Current | 18A | |
| Max PV Charging Current | 120A | |
| Max AC Charging Current | 100A | |
| Max Charging Current (Total) | 120A | |
| Interface & General | LCD Interface | Can display operating mode/load/input/output |
| Communication | RS232 (Baud 2400); Wifi/BMS optional slot | |
| Parallel Interface | Not Support Parallel | |
| Operating Temp | -10°C to 50°C | |
| Humidity | 20%~90% Non-condensing | |
| Noise | ≤ 50dB |
8. User Tips
Based on user experiences, here are some helpful tips:
- Fan Noise: The internal cooling fans may be audible even without significant load. Consider the inverter's placement if noise is a concern. Some users have explored upgrading fans for quieter operation.
- Mounting: Wall mounting brackets are not included in the package. Plan for a suitable mounting solution.
- Battery Terminals: The battery connection terminals are clamp-style, not M8 bolts. Ensure your battery cables are compatible or prepare appropriate connectors.
- Operation Without Battery: The inverter can operate without a connected battery, drawing power directly from solar or AC input to supply loads.
- Idle Power Consumption: The unit draws approximately 62 watts from the power supply when idle.
- Display Readability: The LCD display is informative but can be small for some users.
9. Frequently Asked Questions (FAQ)
Q: Which solar panels should be used for this inverter?
A: For optimal performance, use solar panels that collectively meet the following criteria:
- Max PV Input Power: Up to 8500W.
- MPPT Input Voltage Range: 60-500Vdc.
- Optimal Vmp Range: 300-400Vdc (for best efficiency).
- Max PV Input Voltage: Do not exceed 500Vdc.
- Max PV Input Current: Do not exceed 18A.
Ensure your solar array's open-circuit voltage (Voc) does not exceed 500Vdc under any conditions (e.g., cold temperatures).
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your point of purchase or the official Daxtromn support channels. Please have your model number (JGH-6.2KW) and purchase details ready.
A detailed PDF user manual is available for download from the manufacturer's website for more in-depth instructions and advanced settings: View User Manual (PDF)